- 材质:
- 碳钢
- 规格:
- DN50-DN2000
- 型号:
- YDF
The valve core has no contact with the sealing ring during operation, has low resistance and has a long service life
It adopts an inflatable sealing ring and has good sealing performance
The pneumatic actuator adopts a linear cylinder or sector cylinder for fully enclosed drive , with large output torque and reliable performance, it can meet the needs of working under harsh industrial and mining conditions.
Main technical parameters:
.Model: Type dome valve
.Caliber:,,,,,,,,
3. Nominal pressure:
.Operating temperature: ℃
.Control air source pressure:
.Air consumption:/time
.Cylinder output torque:
.Working medium: granular materials
Working principle:
The valve core of the pneumatic dome valve is a spherical dome. During the switching process of the dome valve, the gap maintained between the valve core and the sealing ring allows the valve core and sealing ring to move in a non-contact manner. The purpose is to ensure that the valve core There is no friction between it and the sealing ring, reducing friction. The pneumatic actuator of the dome valve is a fully sealed linear cylinder or sector cylinder, which directly drives the movement of the dome valve, effectively preventing dust from entering and causing wear, leakage and other phenomena. When the dome valve is in the closed state, the rubber seal is inflated, expanded, and pressed tightly against the spherical dome valve core, thus forming a very reliable sealing ring that prevents the flow of materials in the pipeline.
The dome valve core is made of different materials according to different use occasions, and the surface adopts different hardening treatments. The hard surface of the valve core can ensure good and close contact with the sealing ring to ensure reliable sealing. The rubber sealing ring is made of special rubber, which has the characteristics of high temperature resistance, corrosion resistance, wear resistance, aging resistance and long service life. When the valve is opened, the material port is fully flowing without obstruction. The valve is suitable for gas, liquid, semi-fluid and solid powder and other substances.
Notes:
The inflation pressure of the rubber sealing ring should be guaranteed to be at ., and the maximum output pressure should be ., and the cylinder working pressure should be . Use clean, dry, oil-free compressed air.
Important points for installation and use:
Please read this manual carefully before installation and check the valve model, diameter and technical parameters.
.It is strictly prohibited to install the valve welding flange to avoid damaging the valve sealing ring. The installation size of the reserved valve for the pipeline should be appropriate, and gaskets should be added on both sides of the flange.
3. The center of the two pipes and the diameter center of the valve should be kept coaxial, the flange surface should be flat, and no large deflection of the flange surface is allowed to ensure the clamping and normal operation of the valve. The tightening bolts should be Be even and symmetrical.
.The valve has been adjusted and dynamically tested before leaving the factory, and the gas line connection is intact.
Consumable parts
Main consumable parts: sealing ring and valve core.
Installation dimensions of pneumatic dome valve:
Key points for installation and use:
. Please read this manual carefully before installation and check the valve model, diameter and technical parameters
. Compressed air is It is strictly prohibited to open the valve before discharging. It is strictly forbidden for water and wet materials to enter the valve body
3. It is strictly forbidden to weld the flange after installing the valve to avoid damaging the valve sealing ring. The pipeline should be installed at an appropriate distance from the valve and add gaskets on both sides of the flange
.The centers of the two pipes and the diameter centers of the valves should be kept coaxial, and the flange surfaces should be flat to ensure the clamping and normal operation of the valves
.Regularly inspect the working condition of the dome valve, and handle abnormal situations normally.
.Safe operating procedures should be followed during hoisting, installation, operation, debugging and maintenance
.The valve has been adjusted and dynamically tested before leaving the factory, and the gas line has been connected.
Instructions for ordering pneumatic dome valves:
.Valve type, product name/model/specification
.Valve nominal diameter
3. Maximum operating pressure of the valve
.Valve Maximum operating temperature
.Product application conditions, medium composition
.End connection form and flange implementation standards
.Valve driving method
.Rated flow coefficient
. Part material or other requirements