Schneider Inverter
Schneider Electric Group has provided overall solutions for the energy and infrastructure, industry, data center and network, building and residential markets in many countries, including energy and infrastructure, industrial process control, building It is a world leader in markets such as automation and data center and networking, and also has strong market capabilities in residential applications. Committed to providing customers with safe, reliable and efficient energy.
Series Introduction
The Schneider series is mainly used in three-phase asynchronous motor inverters, with a power range from . to .
Schneider inverter series performance description
Speed regulation through flux vector control
Speed range is to
Inverter and motor protection
Rugged and durable, even in - to In harsh environments of +°C
Wiring and connections by using tie-down screws: easy to replace electromechanical solution
Compact and can be installed side by side
Ability to use rail mounting
Integrated Category B Filters may be available as an option
The frequency converter has extremely low leakage current and is compatible with 3-differential sectionalizers to ensure personnel safety
Baseboard mount version available
Schneider frequency converter range Product Benefits
Simplicity and refined performance
High performance and compact form factor make electromechanical solutions a distant memory
Designed for maximum simplicity, with direct start-up, user-friendly adjustment and quick wiring Function, integrating all the features necessary for use around the world
Application scope of Schneider inverter series
Transportation, garage doors, elevator doors, automatic parking rails, inspection counters, etc.
Grinding machines, drilling machines , training equipment, scrolling display device, telescopic cover, dough mixer, etc.
Series introduction
The Schneider series is mainly used in three-phase asynchronous motor inverters, with a power range from. to.
Schneider inverter performance description
Control method: voltage/frequency ratio, sensorless flux vector control, energy saving ratio
Integrated grade filter
Standard b communication
No need Setting, quick start
Parameter settings can be performed in the package without powering on
The widest operating temperature range: -℃~+℃ without derating, up to +℃
Super strong braking Capability: The rated torque of the motor can be reached without a braking resistor
Fully coated, adaptable to various harsh environments
Excellent quality, components designed according to annual service life
Advantages of Schneider inverter series
br/> Combining the four major advantages of dexterity and exquisiteness, first-class performance, convenient operation and stability and reliability, it is the perfect solution for simple industrial machinery and civil equipment
Application scope of Schneider inverter series
Packaging machinery
Printing machinery
Small material handling equipment
Textile machinery
Medical and health fields
Small fans and pump applications
Others (mixers, washing machines, etc.)
Series Introduction
Schneider inverter series variable torque inverters are mainly used in three-phase asynchronous motor (power range from . to) inverters for building HVAC.
Schneider inverter series performance description
Type/and, power up to
Speed range::
Overload:
Integrated class or class B filter
Main communication buses used in the construction market: , , B and
Compliance with international standards and certifications: ,
Derating technology: immediate operation without harmful effects, no additional skills required for harmonic handling:
Ramp Adaptation to the motor control power supply optimizes energy consumption
Its remote terminal enhances its functions: setting of functions, configuration and downloading and saving of parameters
Compact structure, can be installed side by side
Motors And inverter protection
Economical design
The advantages of Schneider inverter series products are simple and exquisite!
Open to major building communication networks
Economical design, compact, specifically designed to meet your needs
Schneider inverter series application scope
This series is dedicated to building HVAC Applications
All functions necessary for variable torque pump and fan applications Regulator, preset automatic restart, frequency recovery during operation Belt rupture detection Overload detection and underload detection
Common faults and The solution
Fault R: Solution to RR
First power off, then change the display module or remove the display module and install it again, power on again and observe if R is displayed, the display module and control can be eliminated Possibility of poor board contact. In addition, check whether the baud rate of the control board has been changed. If a hardware reset is required, the operation is as follows:
After powering off, turn the frequency selection switch to the position
to the rated voltage. After the inverter, power off
Then turn the frequency selection switch to the position
In addition, you can check whether the fans are spinning. It may be caused by the fans not spinning
Check the frequency converter and Are the versions of the panel incompatible and were they produced in the same period? You can check the number of the inverter and the year it was produced
Check whether the control power supply is overvoltage
Look at the control card and power board Is there any problem with the communication?
The control card is the board under the operation panel.
First unscrew the plastic screws of the operation panel
Then replace the lower board
Note: This control card is universal. After replacing the board, a fault will be reported when powering on. This fault reported after replacing the board can be resolved by pressing a button.
It is also possible that a few wires between your two boards are loose. After removing the board, check to see if the wires are loose.
Solutions to Schneider inverter faults
Check whether the - signal at the input is missing
Check the connection of a given circuit
Schneider inverter 3 series performance description
Built-in and protocol , provides daisy chain,,
Brand new user interface, supports Chinese operation panel
Provides simple and multi-function downloader to facilitate parameter configuration
All coated, adaptable to various harsh environments, frequency conversion The top of the device provides protection level
Modular design of detachable terminals, saving costs and easy installation
Highest withstand voltage in the same level, standard voltage fluctuation -~, allowed voltage drop
and built-in filter
Widest operating temperature, -℃ ~ + ℃ without derating, up to + ℃
Super output characteristics, built-in braking unit, over-torque to ~
Side-by-side installation, saving space
/> Schneider inverter 3 series product advantages
More communication compatibility, more friendly human-computer interaction
Rich application functions, excellent environmental adaptability
Application of Schneider inverter 3 series Scope
The various functions of the frequency converter are suitable for many general applications, including:
Material handling (small conveyors, cranes, etc.)
Packaging machines (
Small bag making machines, Labeling machines, etc.)
General machines (machine tools, textile machinery, etc.)
Pumps, compressors, fans
Schneider inverter 3 series product advantages
More communication compatibility capabilities, More friendly human-computer interaction
Rich application functions, excellent environmental adaptability
Schneider inverter 3 series application scope
The various functions of the inverter are suitable for many common applications, including:
Material handling (small conveyors, cranes, etc.)
Packaging machines (small bag making machines, labeling machines, etc.)
General machines (machine tools, textile machinery, etc.)
Pumps, Compressor, fan
7. Schneider inverter common faults and their solutions
Fault R: Solution to RR
First power off, then replace the display module or remove the display module and install it again Power on again and observe if R is displayed, you can rule out the possibility of poor contact between the display module and the control board. Also check whether the baud rate of the control board has been changed. If a hardware reset is required, the operation is as follows:
After powering off , turn the frequency selection switch to the direction
Turn on the rated voltage, power off the inverter
Then turn the frequency selection switch to the direction
In addition, you can check whether the fans are running. , it may be caused by the fan not rotating
Check whether the versions of the inverter and the panel are incompatible and whether they were produced in the same period. You can check the number of the inverter and the year it was produced
Check Check whether the control power supply is over-voltage
Check whether there is any problem with the communication between the control card and the power board
The control card is the board under the operation panel.
First unscrew the plastic screws of the operation panel
Then replace the lower board
Note: This control card is universal. After replacing the board, a fault will be reported when powering on. This fault reported after replacing the board can be resolved by pressing a button.
It is also possible that a few wires between your two boards are loose. After removing the board, check to see if the wires are loose.
Solutions for Schneider inverter faults
Check whether the - signal at the input is missing
Check the connection of a given circuit
Scope of application
This series is dedicated to the industrial market and construction Pump and fan applications on the market: Superior performance and advanced functions
High-performance variable torque applications:

Fans: Safety with forced functions (fault inhibition, selection of direction of travel and Reference speed)

Multi-pumps: Flexibility, user-friendliness and adaptability in managing multiple pumps through the use of programmable multi-pump cards

Pump categories: Necessary functions required for device underload protection, overload protection and fluid loss detection protection
Performance description
Frequency converter for 3-phase asynchronous motors (power range . to) for variable torque applications series Description
3 Phase/ -/ - /
Type/, from. to
Type/, from. to
Speed Range: In open loop mode:
Overload: ... -
Graphic terminal: plain text, navigation buttons, simple start menu for immediate start, benefit immediately from all features Integrated class or class B filter energy saving method, secondary motor control Compliance with international standards and certifications:, integrated b with Application software
r software for configuration, settings and saving of parameters from the application software Economical design with multiple functions available to protect the motor and frequency converter Safety functions: power off,
Commissioning steps
Schneider inverter debugging steps:
The first step is model confirmation: Confirm whether the model of the inverter is consistent with the model of the purchased inverter. If it is inconsistent, ask the agent to return it.
The second step is transportation confirmation: After opening the package, check whether the inverter is damaged during transportation. If there is any damage, ask the agent to return it.
Step 3: Voltage confirmation: The power supply voltage on site should be within the voltage range accepted by the inverter. Otherwise, all steps below stop.
The fourth step is mechanical installation
The fifth step is the insulation measurement of the motor and frequency converter. Then connect the wiring to the frequency converter: According to the drawing, connect the motor wire to the top, make sure the connection is consistent with the voltage, make sure the power is turned off, connect the main power supply to, connect the control source to the speed reference source. There is a network connection to the network.
Step 6: Power on and debug language modification: After power on, the language selection will be displayed. (This modification is only required for the first time after power-on)
Step 7: Restore factory settings
Step 8: Modify the access level. Electrical maintenance personnel generally set this access level to expert authority.
Step 9: Set the motor parameters such as power, voltage, current, frequency, speed, etc., and perform auto-tuning.
Step 10: Set acceleration and deceleration time: Set a reasonable acceleration and deceleration time.
Step 11: Set the protection parameters, the thermal protection current value of the motor, the current amplitude limit value, etc.
Step 12 Set the control source and frequency source: In the . command, set the channel to start the inverter and the channel to give the frequency. Set the highest frequency, lowest frequency, etc.
The thirteenth step involves the allocation of application functions. Such as braking logic control.
Step 14: Determine the rotation direction of the motor. Set the frequency at a smaller frequency, jog the inverter, and confirm that the rotation direction of the motor is reversed. The parameters can be modified.
Step 15 Record the current value frequency of several frequency bands
Disclaimer

The information/pictures/parameters, etc. displayed on this webpage about【Schneider inverter repair】are provided by member【Tongxiang Yiwei Automation Technology Co., Ltd. 】,By Titker Trade Network members 【Tongxiang Yiwei Automation Technology Co., Ltd. 】is solely responsible for the authenticity, accuracy and legality of the information/pictures/parameters, etc.,Titker Trade Network only provides display services. For your safety, please choose Titker Trade Network for online trading, otherwise Titker Trade Network will not bear any responsibility for this.