Atlas centrifugal air compressor repair kit | Henan Haijie centrifugal air compressor after-sales service. The after-sales technicians of Henan Haijie Compressor Co., Ltd. will summarize various problems after each completion of maintenance work and recommend that everyone choose regular Lubricating oil completes the lubrication of the unit. For more product details, please follow the news updates on this website. All air compressor accessories imported directly from abroad have order contracts, bills of lading, waybills, packing lists and. If you purchase air compressor parts from an imported company, ask them to show the above procedures, otherwise it will be judged as non-imported genuine products. In addition, when identifying the packaging of imported air compressor accessories, you should also note that engineering air compressors and air compressor
manufacturers have their own professional supporting factory parts suppliers. When importing air compressor parts from a manufacturer, the packaging box will have both the mark of the complete machine manufacturer and the mark of the supporting factory. Finally, you can also identify imported air compressor parts based on product quality, which is the most critical link in identifying the authenticity of pure parts. Driven by profit, some dealers assemble imported genuine parts into complete machines and then use genuine parts packaging to package non-genuine parts for sale to the market. If the temperature difference is normal but the machine head is still high, it means that the calorific value of the machine head exceeds the normal range and you should check whether the machine is operating under overpressure. The last thing to note is to check whether the oil cut-off valve is faulty. Failure of the oil cut-off valve usually manifests itself as a jump as soon as the machine is turned on and the temperature rises in a straight line. Regular care and maintenance of the main components of the centrifugal air compressor: In order to ensure the normal and reliable operation of the equipment and ensure the service life of the unit, a detailed maintenance plan must be formulated to perform scheduled operations, regular maintenance, and regular inspection and maintenance to ensure that the air compressor unit maintains Clean, oil-free and dirt-free. The replacement time of cooling lubricating oil in centrifugal air compressor accessories depends on the use environment, humidity, air compressor dust and whether there are acid and alkaline gases in the air. The reason why lubricating oil emulsifies is that the lubricating oil contains water. When the lubricating oil and water are stirred, the lubricating oil will emulsify. The leakage of media caused by loose sealing of the compressor can easily damage the performance of the oil. If the air valve of the air compressor is not closed tightly, the lubricating oil containing a certain amount of moisture in the air jet from the low-pressure safety valve will be emulsified. When the sealing between the piston and the cylinder is poor due to broken and worn piston rings of the air compressor, excessive clearance, wear of the inner wall of the cylinder, etc., hot gas will escape from the cylinder. The maximum reach of the pressurized air in the cylinder is above the level. The inspections that may easily cause oil to age include: Stop the air compressor, remove the low-pressure cylinder cover plate on the upper part of the cylinder head, take out the exhaust valve assembly, pour diesel into the valve slot of the exhaust valve, and find that the diesel from the valve plate matches the valve body. Outflow between the sealing surfaces indicates that the exhaust valve has lost its seal. Remove the fixing nut of the valve plate, take out the valve plates, and inspect them one by one to find out the worn or severely worn parts. During the operation of the air compressor, the long-term repeated impact of the valve plate causes the sealing surface to wear, causing the compressed air in part of the low-pressure cylinder to escape. The effective displacement of the air compressor is reduced in the cylinder. Because the exhaust valve of the low-pressure cylinder is not tightly sealed, when the low-pressure cylinder piston moves downward to inhale, the compressed air in the radiator is sucked back into the low-pressure cylinder, causing the discharge pressure of the low-pressure cylinder to drop rapidly. When the low-pressure cylinder piston moves upward, the pressure of the discharged air rises rapidly. The rising and falling pressure causes the pointer of the low-pressure cylinder exhaust pressure gauge to swing intensified.
Disclaimer
The information/pictures/parameters, etc. displayed on this webpage about【Atlas centrifugal air compressor repair kit | Henan Haijie centrifugal air compressor after-sales service】are provided by member【Henan Haijie Compressor Co., Ltd.
】,By Titker Trade Network members 【Henan Haijie Compressor Co., Ltd.
】is solely responsible for the authenticity, accuracy and legality of the information/pictures/parameters, etc.,Titker Trade Network only provides display services. For your safety, please choose Titker Trade Network for online trading, otherwise Titker Trade Network will not bear any responsibility for this.
If your legitimate rights and interests have been infringed, please contact Titker Trade Network customer service as soon as possible. We will serve you wholeheartedly. Thank you for your attention and support to Titker Trade Network!