- 规格:
- 400×300mm 600×400mm
- 使用温度:
- 260℃
- 材质:
- 精致铸铝及进口优质PFA防腐涂层
The DB series anti-corrosion electric heating plate is an electric heating product specially designed for laboratories. The surface of the aluminum alloy heating plate is treated with fluorine plastic anti-corrosion and non-stick. A powerful assistant for digestion, boiling, acid steaming, and acid removal. It can meet the reagent heating needs of chemical laboratories in different industries such as physics, chemistry, biology, environmental protection, pharmaceuticals, food, beverages, teaching, and scientific research. At the same time, large-area anti-corrosion electric heating plates are launched to meet the needs of laboratories for rapid processing of large batches of samples. Our company's PTFE beakers, crucibles, digestion bottles, sample dissolving tanks, etc. can be used for supporting purposes.
It is one of the essential products for ultra-purification laboratories. In addition, it can be made into a perforated electric heating plate to achieve higher efficiency in digestion and acid removal.
Product Features
.Large-area heating plate, capable of processing large quantities of samples quickly
.Anti-corrosion cast aluminum heating plate with fast heating speed and uniform heating
.Large heating area, capable of processing multiple samples Sample, no cross-contamination
. Anti-corrosion panel, resistant to strong corrosion, easy to clean, convenient to use, long life
. Split design, the control system can be placed outside the fume hood to prevent corrosion of the controller. In addition, The pillars can be replaced with polytetrafluoroethylene material to minimize the pollution of metal parts to the laboratory
.D Precise temperature control, sustainable working for more than hours
.Working temperature: room temperature to ℃
/> .Temperature control accuracy: ℃
Note: When the split electric heating plate is steaming acid, the control system can be placed outside the fume hood to prevent acid vapor from corroding electronic components for a long time and to minimize the impact of acid vapor on metal parts. of corrosion.
Specifications and model parameter values
Product name
Model
Dimensions (mm)
Control method
Temperature control range
Temperature control accuracy
Material
Power
Anti-corrosion electric heating plate
D digital display
Room temperature ℃
℃
Exquisite cast aluminum and imported high-quality anti-corrosion coating
Sample tanks and sample bottles
Soluble polytetrafluoroethylene sample tanks and sample bottles: have extraordinary chemical resistance and can withstand almost all chemical solvents. It can be used to store reagents and standards for a long time without worrying about the precipitation of other impurities. If dropped from a height of 1.3 meters above the ground, the bottle body will not break, the cap will not fall off, and it will not leak. The open mouth can be autoclaved, and the flat design of the outer bottom can be heated and autoclaved with an electric hot plate.
Product name
Specification (m)
Material
Soluble polytetrafluoroethylene
Sample tank, sample bottle
< br/>
According to the experimental requirements, there are designs such as shaped, shaped, and flat bottom. The bottom design makes it easier to collect a small amount of samples. It is often used with our company's electric heating plates, especially the acid-catching electric heating plates with holes, which have excellent results. It is widely used in the preparation and storage of various sensitive analysis samples. It can also be used as a reaction vessel for samples. It is especially widely used in the digestion and dissolution of geological and mineral experimental samples, supporting analysis and other experiments.
Such as: Northwest Nuclear Industry Research Institute, Xiamen University, Yichang Institute of Geology and Mineral Resources, Hangzhou Institute of Geology and Mineral Resources, Nanjing Soil Research Institute of the Chinese Academy of Sciences, Cold and Drought Institute of the Chinese Academy of Sciences, Nanjing Institute of Geology and Mineral Resources, China University of Geosciences (Beijing) , Beijing Institute of Geology of Nuclear Industry, Lanzhou Institute of Geology, etc. are used to store high-purity reagents and standard samples.
Vial bottles with round bottom and inner conical bottom
can be customized.
Product Features
. Resistant to strong acid, strong alkali, aqua regia, magic acid, hydrofluoric acid and various organic solvents
. Low precipitation: extremely low metal ion dissolution and precipitation, ideal for storage Excellent vessel for standard materials, highly corrosive, expensive ultra-high purity reagents
. High and low temperature resistance: operating temperature ~ +℃
. Anti-pollution: extremely low blank value of metal elements
.It is very suitable for high-end laboratories such as trace and ultra-trace analysis and isotope analysis. It is currently the cleanest experimental analysis vessel at home and abroad.
, m, and m are available in three specifications: molded bottom, molded bottom, and flat bottom. Other specifications, m, and m are all flat bottom.
Nanjing Ruinike Technology Development Co., Ltd.
Contact person Su Yang QQ
Mobile phone number
Fax email: @qq