Product Details
Recycling of mixed signal oscilloscopes in large quantities
Dongguan Rongxin Instrument Recycling Co., Ltd.
Contact Mr. Chen (Manager)
Mobile phone
Email@
Address Tangguan City, Dongguan City, Guangdong Province No., Tangxia Avenue, Xia Town
Our company has long-term recycling and sales of world-famous brand products such as multi-purpose oscillator, network analyzer, spectrum analyzer, signal generator, tester, bridge power supply, comprehensive tester card.
Mr. Chen, recycling hotline
Welcome to call us for consultation
Mixed signal oscilloscope
Speed up every stage of debugging! A complete debugging platform, starting from probing
Mixed-signal oscilloscopes have high bandwidth and/or sampling rate, providing the performance needed to view rapidly changing signal details. With up to 100 channels, you can analyze analog, digital and serial signals simultaneously using one instrument. Coupled with innovative control capabilities for automatic serial and parallel bus analysis and automatic power measurement, the system gives you the versatile tools you need to speed the debugging of complex designs.
>
Series Features
Vertical System
Model
Input Channel
Analog Bandwidth
Theoretical Rise Time
(Typical)
Hardware Bandwidth Limit
or
Input Coupling
Input Impedance
Megohm
Input sensitivity in ohms
Input sensitivity in ohms
Vertical resolution
bits
Maximum input voltage in ohms
, peak value
Maximum input voltage ohms
, peak value
Gain accuracy
, where offset is set to
Offset range
Channel-to-channel isolation (any two channels on equal vertical scale)
up to rated bandwidth
>
Horizontal systems
Model
Maximum sampling rate (all channels)
Maximum recording Length (all channels)
Sample points
Maximum duration at highest sampling rate (all channels)
Time base range< br/>
Time Base Delay Time Range
Division to
Channel to Channel Offset Correction Range
Long Term Sample Rate and
Delay Time Accuracy
Over Any Interval
Incremental Time Measurement Accuracy
(/ Sampling Rate + | Readings | + )
Trigger System
Main Trigger Mode Automatically Triggers Normal Trigger and single trigger.
Trigger coupling suppression (attenuation) suppression (attenuation) noise suppression (reduce sensitivity).
Trigger holdoff range.
Sensitivity
When internally coupled, it is increased to 0 at rated bandwidth.
When external (auxiliary input) is used, it is raised to when.
Trigger level range
Any channel from the center grid of the screen.
External (auxiliary input).
Acquisition mode
Sampling collects sampled values.
Peak detection captures narrow glitches at all real-time sample rates.
Average can include waveforms.
The envelope minimum and maximum envelope reflects the peak detection data in multiple acquisitions.
Real-time rectangular wave train averaging reduces random noise and improves resolution.
Scroll mode scrolls the waveform from right to left on the screen at a scan speed less than or equal to /.
Trigger Mode
Edge positive or negative slope on any channel or front panel auxiliary input. Coupling includes noise suppression high frequency suppression and low frequency suppression.
Pulse Width triggers on either a positive pulse or a negative pulse width for a specific time period.
Runt pulse triggers when a pulse crosses one threshold but fails to cross a second threshold before crossing the first threshold again.
Logic triggers an acquisition when any of the channel's logic patterns becomes false or remains true for a specified time. You can use any input as a clock and look for patterns on the edges of the clock. The pattern specified by the four input channels is defined as high, low or indifferent.
Setup/Hold Time Triggers when the setup and hold time between clock and data present in any two input channels exceeds the threshold.
Video and video signals are triggered on all lines of odd and even numbers or on all fields.
Rise/fall time triggers acquisition when the pulse edge rate is faster or slower than the specified value. The slope can be either positive or negative or positive or negative.
(Option) Trigger acquisition on start repeat start stop missing address bit or bit) data or address and data on the bus up to /.
(Option) Trigger acquisition on or and on a bus up to /(channel models only).
(Option) Trigger acquisition on frame start frame type (data remote error, overload) identifier (standard or extended) data identifier and data frame end or loss on signals up to / . You can further specify data to trigger collection at or on specific data values. User-adjustable sample points are set to by default.
Trigger time delay.
The trigger event is delayed by events.
Waveform Measurement
Cursor waveform and screen.
The automatic measurement type can display the largest number of measurement functions on the screen at one time. Measurements include period, frequency delay, rise time, fall time, positive duty cycle, negative duty cycle, positive pulse width, negative pulse width, burst width, phase, positive overshoot, negative overshoot, peak to peak amplitude, high value, low value, maximum value, minimum value, average period Mean period area and period area.
Measure statistical mean minimum value maximum value standard deviation.
Reference Level User-definable automatic measurement reference level can be specified in percentage or units.
Gating uses screen or waveform cursors to isolate specific conditions occurring within the acquisition that are to be measured.
Waveform mathematical operations
Algebraic operations on waveforms, addition, subtraction, multiplication and division.
Mathematical functions integral and differential. spectrum amplitude. Set vertical scale to linear OR and window to rectangular OR.
Advanced math operations define comprehensive algebraic expressions, including waveform math functions, scalars, up to two user-adjustable variables, and parameter measurement results, such as).
Software
Tektronix Edition is a comprehensive interactive measurement software environment optimized for the series. You can use an intuitive drag-and-drop user interface to instantly acquire, generate, analyze, compare, import and save measurement data and signals without requiring any programming. The software provides standard series support for acquisition control, viewing and exporting real-time signal data. In addition, additional signal processing advanced analysis mixed signal sweep limit testing and user-defined step functions are provided during the trial period, and the functions can be activated at any time with the lowest license fee. Please contact us for details.
Communicate quickly and easily between or between and series. Transfer and save setup waveform measurements and screen plots.
Drivers provide standard instrument programming interfaces such as / and .
Monitor Features
Monitor type inches mm) LCD color monitor.
Monitor resolution horizontal and vertical pixels.
Waveform display style vector point variable persistence infinite persistence.
Input
/
Output port
Drive front panel access (type).
Fast host port supports mass storage devices and printers. Two ports are provided on the rear panel and one port on the front panel.
The Speed Device Port rear panel connector can be used to pass or control an oscilloscope.
Port connector support /.
The video port female connector connects to an external monitor or projector to display the oscilloscope screen.
Auxiliary input front panel connector. Input impedance Megohms. Maximum input, peak value.
The probe compensator outputs the front panel pins, amplitude, and frequency.
The trigger output rear panel connector provides a positive pulse when the oscilloscope triggers acquisition.
Adapter provides a connector for connecting multiple instruments in the future.
The lock rear panel security slot attaches to a standard lock.
Power supply
Supply voltage
Power supply frequency)
).
Maximum power consumption.
Other Features
Cooling Clearance Cooling clearance requires inches (mm) of clearance on the left and back of the instrument.
Environmental characteristics
Temperature
Working temperature ℃ to +℃
Non-operating temperature ℃ to +℃
Humidity
Relative humidity when the working humidity is less than or equal to +℃ . The upper limit drops to relative humidity at +°C.
Relative humidity when non-operating humidity is less than or equal to +℃. The upper limit drops to relative humidity at +°C.
Altitude
Working altitude in meters.
Non-operating altitude meters.
Random Vibration
Work Random Vibration per axis minutes per axis minutes total.
Non-operating random vibration
Minutes per axis and minutes total for the axis.
Regulations and Standards
Electromagnetic compatibility.
Security 2nd Edition 2nd Edition.
Disclaimer
The information/pictures/parameters, etc. displayed on this webpage about【Long-term mass recycling of DPO4054B mixed-signal oscilloscopes】are provided by member【Rongxin Electronic Instruments Recycling Co
】,By Titker Trade Network members 【Rongxin Electronic Instruments Recycling Co
】is solely responsible for the authenticity, accuracy and legality of the information/pictures/parameters, etc.,Titker Trade Network only provides display services. For your safety, please choose Titker Trade Network for online trading, otherwise Titker Trade Network will not bear any responsibility for this.
If your legitimate rights and interests have been infringed, please contact Titker Trade Network customer service as soon as possible. We will serve you wholeheartedly. Thank you for your attention and support to Titker Trade Network!