Product Details
Nanning Chigo central air-conditioning after-sales service outlet repair hotline: Or, the dedicated line will serve you at home. Chigo central air-conditioning after-sales maintenance will warm the hearts of millions of families. Chigo central air-conditioning after-sales maintenance guarantees your satisfaction. Chigo central air-conditioning after-sales maintenance. Original parts, Chigo central air conditioner after-sales maintenance, serving the people with honesty and trustworthiness, on-call service, considerate quality and the best quality!
Chigo central air-conditioning after-sales maintenance telephone hourly repair hotline: or Chigo central air-conditioning brand professional repair station repair hotline (whole-step door-to-door service to provide you with the best service! Chigo central air-conditioning professional maintenance)
"Chigo" "Factory" "Home", "Point", "Ding", "Weight", "Repair", "Middle" and "Heart"
Or "Energy Saving and Emission Reduction" Green energy and harmonious world is the mission of after-sales service. The company is bringing high-quality life to consumers. At the same time, it is also practicing the low-carbon dream of benefiting mankind. Looking forward to the future, Huizhong Central Air Conditioning will adhere to the development ideas of saving enterprises with technology, revitalizing enterprises with quality, and promoting enterprises with efficiency, with the goal of creating the world's leading central air conditioning enterprise and establishing Huizhong Central Air Conditioning as a century-old world brand, and contribute more to China's creation. Much power. Service only has a starting point, satisfaction has no end point, satisfaction has no end point, service has only a starting point
Nanning Chigo Central Air Conditioning after-sales service consultation telephone number "Implementing the quality of maintenance service standards in the home appliance industry"
Nanning Chigo Central Air Conditioning after-sales telephone number: or
Chigo Central air-conditioning after-sales (manufacturer) unified maintenance customer service center telephone number. One of the following situations does not fall within the scope of guaranteed repairs. Special service outlets can carry out repairs for a fee in accordance with the relevant provisions of this manual:
Consumers caused by improper use, maintenance, and storage Damaged
Damage caused by installation or repair at an electrical appliances service outlet other than the one designated by the company (including installation or disassembly and repair by consumers themselves)
No warranty certificate and valid or valid purchase voucher
/>Repair acceptance hotline at the after-sales center office: or service procedure: call for repair, come to check, quote the actual price, repair, recover, and provide warranty.
Safety, standardized maintenance, and regular maintenance. The accessories are authentic and come with a warranty.
Service goal: % customer satisfaction for service defects. As long as you call the company's after-sales service hotline: or the company will serve you wholeheartedly as soon as possible. Service scope: There are maintenance points in every city
Chigo In the inverter central air conditioner, the compressor is protected as soon as it is started
. Fault phenomenon
The outdoor unit indicator light is on, but the compressor is protected as soon as it is started, showing an overcurrent protection code.
.Fault Analysis
The main causes of this fault are: first, abnormality in the power module or its power supply; second, abnormality in the control circuit; and third, abnormality in the compressor.
.Inspection
The first step is to check the power supply circuit of the power module. First, touch the starting resistor with your hands to see if it is very hot. If so, the relay in the main control circuit may not close, and the starter that has not completed starting will be short-circuited. The large working current generated when the compressor is running has to pass through the starting resistor. Secondly, check whether the filter capacitor (large-capacity electrolytic capacitor) has failed.
The second step is to measure the voltage at each output terminal of the outdoor unit switching power supply. If it is too high, it means that the fault lies in the switching power supply. First, replace the electrolytic capacitor of the wearing parts on the left side of the switching transformer at the same time, and then check other components of the voltage stabilizing circuit.
The third step is to unplug all the connecting wires between the power module and the compressor and test the machine. Measure the voltage between the three-phase output pins of the module. There are left and right voltages between any two-phase output pins and they are equal. Most of them are compression. Otherwise, if any two-phase output pins have no voltage or are unbalanced, it usually means that the power module is damaged or there is a problem with its control circuit.
Methods to further confirm the quality of the power module: Pull out all the connecting wires of the power module, measure the forward and reverse resistance of the opposite terminal of the module, which should conform to the characteristics of the diode, that is, there is a certain resistance in the forward direction and a certain resistance in the reverse direction. The resistance is infinite.
Chigo central air-conditioning after-sales maintenance service commitment:
Strictly follow maintenance procedures and operating regulations to ensure maintenance quality.
Strictly control the quality of accessories and eliminate the use of fake and inferior accessories as well as waste accessories.
The service hotline is manned every hour and will respond within hours. During the maintenance period and during holidays, Chigo's front desk will not take a break to ensure that users are always on hand for repairs. We have established a maintenance system and set up a repair team in time to arrive at the site for repairs at any time.
In terms of charging, we strictly implement the charging standards of the Municipal Price Bureau and our company, do not exaggerate faults, and prevent arbitrary charging.
Remote fault diagnosis, technical troubleshooting, and quick delivery of postal accessories for out-of-town customers. If out-of-town customers send their machines for repair themselves, we will expedite troubleshooting and strive to complete the repairs on the same day.
The machines repaired by our center's Chigo central air conditioners will all be subject to warranty. If there are problems due to the quality of repairs or replacement parts during the warranty period, our center will be responsible for repairs.
Service goal: Defects, % customer satisfaction, the city listens to customers carefully. Hourly after-sales service telephone number: or
Hourly after-sales repair telephone number of Chigo central air-conditioning: or after-sales service telephone center group welcomes
Technology condenses the power of wisdom and central air-conditioning achieves a happy life
Chigo central air-conditioning after-sales service seasons are changing and our services remain unchanged!
Disclaimer
The information/pictures/parameters, etc. displayed on this webpage about【2015 Nanning Zhigao central air conditioner after-sales maintenance phone number (cannot start)】are provided by member【Yishi Home Appliances Maintenance Department, Nanning
】,By Titker Trade Network members 【Yishi Home Appliances Maintenance Department, Nanning
】is solely responsible for the authenticity, accuracy and legality of the information/pictures/parameters, etc.,Titker Trade Network only provides display services. For your safety, please choose Titker Trade Network for online trading, otherwise Titker Trade Network will not bear any responsibility for this.
If your legitimate rights and interests have been infringed, please contact Titker Trade Network customer service as soon as possible. We will serve you wholeheartedly. Thank you for your attention and support to Titker Trade Network!