Hello and welcome toTitker Trade Network!
Independent Smoke Detector, Independent Gas, Networked Smoke Detec

free member

Factory direct sales JB-TG(B)ZL-JLV3 fire alarm controller

total supply
10000 台
MOQ
1 台
brand
立安鑫
area
GuangdongShenzhen
Delivery period:
Shipped within 1 days from the date of payment by the buyer
Buyers are still looking
  • 1
  • 2
  • 3
Products Recommended

24V power supply sou

¥1.00/台

Household independen

¥1.00/台

Factory direct sales

¥1.00/台

Household wall-mount

¥1.00/台

Foreign trade export

¥1.00/台

Supply of networked

¥1.00/台

Shop information

area:Guangdong Shenzhen

Member level:corporate memberYear1

identity:  

Already paid:0.00 yuan deposit

my badge: [Integrity File]

online service:

Business card

Shenzhen Lianxin Electronic Technology Co

Applets
【Kind tips】When you call, please mention that you saw us on Titker Trade Network, thank you.
Product Details
工作电压:
AC220V/50HZ
工作温度:
-10℃~+50℃
相对湿度:
≤95%,不结露
B(B)
Type fire alarm controller (linkage type)
Introduction
The series fire alarm controller (linkage type) is based on the national standards B "Fire Alarm Controller" and B "Fire Protection Controller" A new generation of high-tech products developed by "Linkage Control System".
This controller adopts cabinet type (B) or wall-mounted type () structure, software modular design, and large-screen Chinese character LCD display. It has the characteristics of powerful functions, high reliability, and flexible configuration.
This controller can realize the two functions of fire alarm and fire extinguishing linkage at the same time, and can be matched with various types of fire detection components and linkage components produced by our company. Suitable for the application of large and medium-sized fire alarm and fire protection linkage integrated control systems.
A single controller can be connected to a bus control unit and a dedicated line control unit. This controller can operate in a network with multiple controllers, and the maximum number of controllers in the network can reach 3 controllers.
Fire alarm detectors (such as smoke detectors, heat detectors), bus-type linkage components (such as input and output modules, etc.) and floor display panels can be connected to the same alarm bus, which is convenient for construction and installation. Save on wiring.
Main features and technical indicators
◆Integrate fire alarm and comprehensive control functions in one body and comply with the latest national linkage fire controller standards
◆Full Chinese LCD screen operation interface, menu-type dialog box, Simple and convenient operation with Chinese character annotation function
◆The non-polar two-wire bus system is simple and convenient to install and wire.
◆System capacity: configurable ~ loop (distributed on multiple circuit boards), each loop can be configured with a smart Detectors and smart modules can be connected to up to 2 smart detectors and smart modules
◆Network mode: multiple controllers connected to the network
Multiple master or master-slave modes can be selected to form a multi-unit network system. Implementing master-slave control can also achieve peer-to-peer network sharing.
◆With R communication interface
◆Linked logic on-site programming
◆Black box function to trace historical records
◆With Chinese character annotation function
◆With strong resistance to industrial electromagnetic Interference ability.
◆Main power supply voltage
◆Backup power supply voltage
◆Protection measures: power supply short-circuit self-protection function, circuit short-circuit self-protection function
◆Using environment: temperature ~ +℃< br/>Relative humidity %
~%
(no condensation)
◆Dimensions: Cabinet machine
Wall-mounted machine
◆Weight: Cabinet machine: Wall-mounted machine: .
Wiring and installation
The power lines, ground wires, start wires, and stop wires from the controller to the field equipment should meet the following requirements:
) When the line passes the maximum current, the wire diameter and thickness It should be ensured that the line voltage drop is less than
). When there are many linkage devices, the load capacity of the controller should also be considered. If the load is insufficient, you can increase the load capacity of the controller, or reduce the number of simultaneous starts of the linkage equipment, or reduce the number of instantaneous The problem can be solved by starting the equipment at a slightly staggered time.
Wiring terminal description:
~ It is a bus loop output terminal block of the main control unit, which can be connected to various detectors, bus modules, etc. of the company.
~ It is a dedicated line output terminal block that can be connected to various dedicated line modules.
In the four-wire terminal, the and are the system loop signal wires. Use the yellow wire and the green wire to connect the wires to the system ground wire respectively. Use the black wire to connect the + wire to the positive voltage output of the power supply unit and the red wire to connect it.
Among the six-wire terminals, , B, and are the system power configuration signal line terminals, which are connected to the green, blue, red and black power configuration signal lines respectively. and are fire alarm relay output terminals. B and B are external bus terminals, used for controller networking. R, and are R communication terminal blocks, which are used for serial communication between the controller and R. Our company provides users with a dedicated data download line. The R, and terminals are connected to the green line, yellow line and black line of the data download line respectively.
"Factory direct sales JB-TG(B)ZL-JLV3 fire alarm controller"Related Products
Related categories
Security monitoring equipment Monitor transmission equipment Monitoring and recording equipment Locks Anti-theft alarm equipment Building intercom equipment 门禁考勤器材及系统 smart card Fire Equipment traffic safety facilities Traffic control management equipment Traffic detection equipment Static electricity tester smart transportation Home intelligence Security inspection equipment Explosion-proof equipment Anti-counterfeiting technology products Biometric technology equipment public address system Lightning protection equipment Anti-static products Information security products Military supplies and police equipment Work protection natural disaster protection Sports protective gear Self-defense gear life-saving equipment Inventory/second-hand security products Processing cooperation Other uncategorized
Related Information
Firefighting foam tank PHYM32/15 Ningxia PHYM vertical storage tank press PSY40 mobile fire water cannon manufactu Stainless steel safety exit sign luminou Black stainless steel bus sign, special pvc luminous floor stickers luminous fir Luminous Film Luminous Film High Brightn Stair anti-slip strips L-shaped stair an Tempered glass floor sticker with steel Stainless steel luminous floor stickers, 304 stainless steel luminous arrow scree Luminous floor stickers stainless steel Stair step evacuation instructions facad Tempered glass floor sticker with steel Tempered glass floor stickers for shoppi
Disclaimer

The information/pictures/parameters, etc. displayed on this webpage about【Factory direct sales JB-TG(B)ZL-JLV3 fire alarm controller】are provided by member【Shenzhen Lianxin Electronic Technology Co 】,By Titker Trade Network members 【Shenzhen Lianxin Electronic Technology Co 】is solely responsible for the authenticity, accuracy and legality of the information/pictures/parameters, etc.,Titker Trade Network only provides display services. For your safety, please choose Titker Trade Network for online trading, otherwise Titker Trade Network will not bear any responsibility for this.

If your legitimate rights and interests have been infringed, please contact Titker Trade Network customer service as soon as possible. We will serve you wholeheartedly. Thank you for your attention and support to Titker Trade Network!

Titker Trade Network