Product Details
Samsung submersible pump sales champion product in Fengxian District, Shanghai
Overview of sewage and sewage submersible pump products in Fengxian District, Shanghai:
, type sewage and sewage submersible pump (hereinafter referred to as electric pump), implements B/- standard, electric The pump consists of three parts: a water pump, a seal and an electric motor. The electric motor is located on the upper part of the electric pump. It is a single-phase or three-phase asynchronous motor. The water pump is located on the lower part of the electric pump. It has a non-blocking flow channel impeller and volute structure. A double-end machine is used between the water pump and the motor. Sealing, each fixed stop seal uses a shaped oil-resistant rubber sealing ring for static sealing.
Shanghai Fengxian District/Sewage and sewage submersible pump uses:
Shanghai Fengxian District/Sewage and sewage submersible pump is widely used in industry, agriculture, construction, municipal environmental protection and other places, and can pump materials containing short fibers, paper It is an ideal water conservancy equipment for agricultural irrigation and river dredging, but it is not suitable for use in environments with explosion-proof requirements.
Shanghai Fengxian District/Sewage submersible pump usage conditions:
, the medium temperature does not exceed +℃
, the value of the medium is between -
The density of the medium is not greater than
/>, the power frequency is .times of the voltage fluctuation range of the rated value
, and the diving depth does not exceed.
Submersible electric pumps work underwater. It is compact and lightweight, does not pump water from the well and does not require a long drive shaft. Therefore, submersible electric pumps are very suitable for rural well water irrigation. The most widely used type is the B-type submersible electric pump. This kind of submersible electric pump uses waterproof measures such as mechanical seals or air seals to keep the inside of the motor dry and free from water intrusion. Pay attention to the following points when using:
Check whether the seals on the air vent, water drain, oil drain hole and cable joint of the pump are loose. If they are loose, they must be tightened.
Use a voltmeter to check the insulation resistance. It should be no less than . megohm. If it is lower than this value, open the water and vent holes for drying or sun-drying.
Check the cable. If it is cracked or broken, it should be replaced to avoid leakage.
Before starting, check all circuits and switches to see if the wiring is correct and secure. Then let it idle for 3 to 3 minutes on the ground (the time should not be too long to avoid damaging parts or burning the motor windings), and check whether the motor is rotating in the correct direction. If there are no problems as mentioned above, it can be put into water for use.
When the submersible electric pump is put into the water for use, the cable must not be stressed. It should be tied to the wooden frame at the wellhead with a rope. The maximum depth that the electric pump can be put into the water is 3 meters, and the minimum depth is . meters (from the center of the impeller).
During operation, changes in water level in the well should be frequently observed. The motor must not be exposed to the water or sink into the mud, so as not to affect the heat dissipation of the motor and burn the windings. The electric pump should be raised and lowered at any time as the water level in the well changes. If the water volume decreases or is interrupted, the cause should be immediately identified or shut down for inspection. The cable must not rub against the well wall to prevent well water from seeping into the motor along the cable core after the cable is worn out.
For new or replaced submersible pumps with integral sealing boxes, after using them for hours, you should check whether the sealing is in good condition. In the future, check once a month. Also check whether the sealing of the shielding sleeve between the motor rotor and stator is in good condition.
After one year of use, the pump should be inspected for corrosion, removed and painted.
If the submersible electric pump will not be used for a long time, it should be carefully inspected and stored in a dry and ventilated house.
Disclaimer
The information/pictures/parameters, etc. displayed on this webpage about【Samsung submersible pump sales champion product in Fengxian District, Shanghai】are provided by member【Shanghai Samsung Water Supply and Drainage Equipment Co
】,By Titker Trade Network members 【Shanghai Samsung Water Supply and Drainage Equipment Co
】is solely responsible for the authenticity, accuracy and legality of the information/pictures/parameters, etc.,Titker Trade Network only provides display services. For your safety, please choose Titker Trade Network for online trading, otherwise Titker Trade Network will not bear any responsibility for this.
If your legitimate rights and interests have been infringed, please contact Titker Trade Network customer service as soon as possible. We will serve you wholeheartedly. Thank you for your attention and support to Titker Trade Network!