Resistance requirements of high-voltage ground rods: The resistance requirements of high-voltage short-circuit ground rods to ground determine the quality of the ground rods. Generally, according to the power industry/technical regulations, the resistance of the ground rods of each cross-sectional area to the ground shall not be greater than the following values:
The resistance to ground is as follows: Measure the DC resistance between the wiring lugs. For various cross-sections of ㎡, 3㎡, ㎡, ㎡, ㎡, ㎡, the average resistance value per meter should be less than .,.,.,.,., respectively. ..
Soft copper wire model classification: Model: *+ ground rod, 3*+ ground rod, *+ ground rod, 3*+ ground rod, 3*3+ ground rod.
3) Grounding rod clamp or grounding pin
The wire clamp and grounding clamp are made of high-quality aluminum alloy die-casting with surface oxidation treatment.
The grounding pin is welded with B/ standard carbon structural steel, and the surface is hot-dip galvanized.
4. Instructions for use
.Using environment:
Indoor:
For indoor use, the power equipment is connected to the ground. The wiring clamp adopts a flat spiral type, and the grounding method adopts a ground rod. Clamp (connecting busbar and copper bar type). Low-voltage grounding rods are divided into two types: grounding rods for indoor equipment and grounding rods for outdoor lines. Generally, low-voltage lines adopt a three-phase four-wire system.
Outdoor:
The outdoor circuit adopts double spring type, and the grounding method adopts ground nail method.
.Installation operation
) Verify whether the voltage level of the ground rod is consistent with the voltage level of the operating equipment.
) Installation: Fix the double-eye copper nose on the grounding soft copper wire to the corresponding position of the electric clamp on the ground rod (the electric clamp has fixed and movable types), and connect the single-eye copper nose on the ground rod. The copper nose is fixed on the ground clamp or ground pin to form a complete set of ground rods.
3) The human body must not come into contact with the grounding rod or unbroken wire to prevent induction conduction.
) In places with high induced voltages, construction workers should also wear anti-static clothing.
) A grounding warning sign must be hung at the grounding point.
) When hanging the ground rod: connect the ground clamp first, then connect the electric clamp. When removing the ground rod, you must follow the procedure to first disconnect the electric clamp, and then remove the ground clamp.
) It is strictly prohibited to use a wire clamp instead of winding to create a ground short circuit.
) If there is a grounding point at the suspension point, a grounding rod clamp or a special copper rod should be used for grounding connection. If there is no fixed grounding point available, a temporary grounding point can be used. The depth of the grounding electrode buried underground should not be less than .
) Portable short-circuit grounding rods should be properly kept. Before each use, you should carefully check whether it is intact, the soft copper wire is not exposed, and the nut is not loose, otherwise it must not be used.
) The inspection cycle of the portable short-circuit grounding rod is once every five years, and the inspection items are the same as the factory inspection. After the portable short-circuit grounding rod that has passed the test is subjected to a short circuit, it should be judged based on the size of the short-circuit current and appearance inspection, and generally should be scrapped.
If you want to know more
products
for details, call immediately
National sales hotline: (same number on WeChat),
Disclaimer
The information/pictures/parameters, etc. displayed on this webpage about【Tianjin high voltage ground rod】are provided by member【Shijiazhuang Jinneng Electric Power Equipment Co., Ltd.
】,By Titker Trade Network members 【Shijiazhuang Jinneng Electric Power Equipment Co., Ltd.
】is solely responsible for the authenticity, accuracy and legality of the information/pictures/parameters, etc.,Titker Trade Network only provides display services. For your safety, please choose Titker Trade Network for online trading, otherwise Titker Trade Network will not bear any responsibility for this.
If your legitimate rights and interests have been infringed, please contact Titker Trade Network customer service as soon as possible. We will serve you wholeheartedly. Thank you for your attention and support to Titker Trade Network!