Hello and welcome toTitker Trade Network!
Electric fan air volume measurement device, range hood grease sepa

free member

GB/T18801 purifier CADR test cabin

价格 5000.00元/台
total supply
100 台
MOQ
1 台
brand
德迈盛DMS
area
Guangdong
Delivery period:
Shipped within 3 days from the date of payment by the buyer
Buyers are still looking
  • 1
  • 2
  • 3
Products Recommended

GB/T31476.3 Battery

¥5000.00/台

Shenzhen Demaisheng

¥5000.00/台

DMS-Enthalpy chamber

¥5000.00/台

Which battery washin

¥5000.00/台

GB/T31476.3 Battery

¥5000.00/台

DMS-battery vacuum d

¥5000.00/台

Shop information

area:Guangdong

Member level:corporate memberYear1

identity:  

Already paid:0.00 yuan deposit

my badge: [Integrity File]

online service:

Business card

Shenzhen Demaisheng Measurement and Control Equipment Co., Ltd.

Applets
【Kind tips】When you call, please mention that you saw us on Titker Trade Network, thank you.
Product Details
200:
325
300:
56
71:
82
1.
>Purifier test cabin
Equipment introduction
This test bench is mainly used to simulate and detect the air purifier pollutant removal test basis
- Design and production of air purifier.
This test bench is mainly composed of laboratory, air circulation device, exhaust system, sample adding device, equipment electrical control system (electrical switches, sensors, etc.).
< < Purifier test cabin
Main components
.Laboratory
.Laboratory composition
.:
.Test room, fluorescent lamp,. Household ceiling fan , test bench, power socket, etc.
.
.Dimensions
.:
.= * *
.
.Leakage rate
. :
.Leakage rate
.
.Material
.:
. Stainless steel observation window with tempered glass inner wall equipped with sampling hole
.
.Equipment installation
.:
Reserve an installation port on each side and use it as an internal air circulation inlet and outlet. Reserve a special exhaust port at the top near the side and install a closed hatch. , reserve sampling holes and adding holes (+), install a household ceiling fan and a fluorescent lamp on the top
. Installation process
.:
. All connection parts use silicone rubber strips and Glass silica gel is used for sealing to ensure the airtightness of the laboratory
.
.Air circulation device
.Equipment composition
.:
.Circulation fan, pipeline, medium-efficiency filter, high-efficiency filter, regulating air valve, etc.
.
.Fan (technical parameters)
.:
.Circulating fan: Air volume:/Full pressure:
.
.Material
.:
. The circulation pipes are all made of stainless steel
. Equipment installation:
. Connect the air inlet of the circulation fan to the reserved side of the laboratory and use it as the air inlet for air circulation and install a damper on it. After the air valve, install a medium-efficiency filter with a filtration efficiency of .%, and then install a high-efficiency filter with a filtration efficiency of .% at the outlet of the circulation fan, and then install a regulating valve outlet connected to the one already reserved in the laboratory. Installation port on the other side
. Installation process:
. All connection parts of the pipeline are sealed with sealing strips and glass silicone to prevent the entry of external particles during the circulation process.
.Exhaust system
.System composition
.:
.Axial fan, damper, pipe, adjustable blinds, waterproof blinds
.
.Fan
.:
. Axial flow fan: Air volume: / Full pressure:
.
.Material
.:
. Pipes are all made of stainless steel. (or galvanized sheet)
.
.Equipment installation
.:
.Connect one end of the pipe to the reserved exhaust port of the tester and install the adjustable shutter on the exhaust The other end of the outlet is connected to the air valve and then to the axial flow fan discharged outside the room
. Installation process:
. The overall connection is flanged. All connection parts are sealed with sealing strips and glass silicone. The connections between all blades of the air valve are handled with sealing strips
.
.Equipment electrical control system
.Equipment composition
.:
.Operator, electrical switch, power meter, button switch computer, data collector, power meter, etc.
.
.Electrical installation
.:
.Comply with electrical related standards
.
.Equipment composition
.:
.Sampling device : Vacuum pump, electronic cigarette lighter, camera tripod, and sampling port constitute the sampling device: trachea, camera tripod
.
. Main functions
.:
. Pollutant filling and Collect particulate matter using
.
< < Main measurement parameters
<- d: d: Measurement items
d: Range/signal range
d: Measurement accuracy
d: Voltage
d: ~
d:
d: Current
d: ~
d:
d: Power factor
d: . ~
d:
d: frequency
d: ~
d:
d: temperature
d: -~℃
d: . ℃
d: Humidity
d: %~%
d: %

Enthalpy difference chamber refrigerator energy efficiency test room electric fan air volume laboratory range hood grease separation Test device Range hood air performance test device Range hood odor reduction test device Battery extrusion testing machine Battery short circuit testing machine Battery heavy object impact testing machine Battery free drop testing machine Battery combustion testing machine Battery washing testing machine Battery acupuncture testing machine Air purifier test cabin
If you need a quotation, please contact -, Ms. Rao, welcome to the factory for on-site inspection! >Purifier test cabin
"GB/T18801 purifier CADR test cabin"Related Products
Related categories
室内环保检测仪器 Meteorological instruments gas analyzer Chromatograph Rubber and plastic special instruments Test chamber and climate environment equipment Thermometers Pressure instrument biological instrument flow meter Mechanical measuring instruments Experimental equipment Measuring standard instruments valve sensor Measuring tools measuring instrument Weighing instrument Level instrument Display instrument Transmitter Environmental testing instruments Logger counter Industrial timer Control (regulating) instruments Actuator base instrument Testing Machine Analytical Instruments Optical Instruments Electrical instrumentation car instrument Non-destructive testing instruments Electronic measuring instruments Special instrumentation Instruments and accessories Pneumatic unit combination instrument Electric unit instrument cluster Instrument power supply Automated complete control system Centralized control device Inventory instrumentation Packaging testing equipment Second hand instruments Other uncategorized Disinfection machine VOC detection equipment Ray detection equipment Formaldehyde detection equipment Benzene detection equipment Ammonia gas detector Other indoor environmental testing instruments
Related Information
Plastic pipe pressure blasting pipe hydr WSD-8701 bicycle frame vertical force fa WSD-8702 bicycle frame pedal force fatig WSD-8703 Bicycle Frame Horizontal Force WSD-8801 Automotive Tie Rod Ball Head Hi Micro dynamic torque testing machine WSD WSD-8601 furniture frame combined compre WSD-8401 Electric Treadmill Mechanical F Vertical combustion testing machine WSD- WSD-8505 Stroller Stability Testing Mach Wheelchair walker mechanics comprehensiv Industry-leading comprehensive mechanica Yuncheng bending tester quality service Zhoukou sapphire static pressure testing Beipiao ceramic bend tester is affordabl
Disclaimer

The information/pictures/parameters, etc. displayed on this webpage about【GB/T18801 purifier CADR test cabin】are provided by member【Shenzhen Demaisheng Measurement and Control Equipment Co., Ltd. 】,By Titker Trade Network members 【Shenzhen Demaisheng Measurement and Control Equipment Co., Ltd. 】is solely responsible for the authenticity, accuracy and legality of the information/pictures/parameters, etc.,Titker Trade Network only provides display services. For your safety, please choose Titker Trade Network for online trading, otherwise Titker Trade Network will not bear any responsibility for this.

If your legitimate rights and interests have been infringed, please contact Titker Trade Network customer service as soon as possible. We will serve you wholeheartedly. Thank you for your attention and support to Titker Trade Network!

Titker Trade Network