After on-site observation, the plated bright nickel layer was in the form of mist. When the anode plate was taken out for inspection, it was found that the anode plate was wrapped in a double-layer canvas. When the canvas was opened, the surface of the nickel plate was pitted and had the smell of chlorine. Most of the surface was The brown color shows that this failure is caused by the anode being bandaged too tightly. After identifying the crux, the original wrapped canvas anode plate was removed, washed with hydrochloric acid, and then wrapped with solid cloth and supplemented with sodium chloride, nickel salt and other materials. The problem was completely solved. It can be seen that it is impossible not to wrap the anode plate, otherwise the dissolved sludge on the anode plate will be deposited on the cathode along with the nickel ions, causing burrs in the coating. It is also not possible to wrap it too tightly, otherwise the above faults will occur. In short, it must be appropriate and frequent inspections should be made to detect problems. be resolved promptly.