- 型号:
- 齐全
- 品牌:
- 九州
d. Turn on the compressed air and check the stop valves, water separation filters, pressure regulators and lubricators of each joint of the compressed air pipeline.
d Use pitot tubes to simultaneously measure the dynamic pressure values at each air inlet short pipe of the ash hopper. If the readings are different, use a manual butterfly valve to adjust them to make them equal to ensure that the load of each filter chamber is equal. After adjustment, lock the manual butterfly valve. .
d. Open the manual butterfly valve for back-blowing air to the required back-blowing air volume.
d. When the dust collector equipment starts to remove dust, do not start the backflush cleaning device immediately. The dust should be allowed to slowly accumulate on the inner surface of the filter bag.
Hebei Jiuzhou Environmental Protection Equipment Engineering Co., Ltd.
Telephone:
Postal Code:
Address: Siying Development Zone, Botou, Hebei Province
Contact: Ms. Yang
Phone:
Email: @.