Hello and welcome toTitker Trade Network!
建筑扣件,移动脚手架,步步紧,混凝土养护室,混凝土养护箱,钢管底座,钢管接头,止水钢板,碗扣架,轮扣架,盘扣架,及建筑器材仪器仪表等

free member

Concrete standard curing box

价格 1800.00元/台
total supply
1000000000000 台
MOQ
1 台
brand
东胜
area
HebeiCangzhou City
Delivery period:
Shipped within 1 days from the date of payment by the buyer
Buyers are still looking
  • 1
  • 2
  • 3
Products Recommended

Concrete engineering

¥15.00/台

Container standard c

¥21000.00/台

template card hook

¥0.30/台

Concrete electronic

¥900.00/台

Construction plate b

¥6500.00/台

Concrete standard cu

¥1500.00/台

Shop information

area:Hebei Cangzhou City

Member level:corporate memberYear1

identity:  

Already paid:0.00 yuan deposit

my badge: [Integrity File]

online service:

Business card

河北东胜建筑设备仪器厂

Applets
【Kind tips】When you call, please mention that you saw us on Titker Trade Network, thank you.
Product Details

-Type concrete standard curing box
It is designed and produced according to the national construction industry industry's standard curing requirements for concrete specimens. It is suitable for standard maintenance work on cement and concrete samples at various construction sites and scientific research and quality inspection departments for strength shaping and setting time.
Main technical parameters:
, Humidity control temperature: r% or above
, Control temperature: ℃℃
, Power supply voltage
, Heating power:
, Refrigeration power:
, Humidification power:
, Humidification volume: ml/hour
, Humidifier volume:
, Box space:
Model can be placed Concrete test block group
Concrete test block group can be placed in the type
Concrete test block group can be placed in the type
3. Structure and working principle:
, Structure
The box adopts The inner and outer layers consist of an outer box and an inner box. The outer box is made of high-quality cold-rolled steel plates. The inner box is made of stainless steel plates. The shelves are made of stainless steel profiles and have good corrosion resistance. The water tank under the inner box is used for heating and auxiliary humidification. The humidification system uses an ultrasonic humidifier as the main water heating and evaporation as the auxiliary. The automatic control system uses a temperature controller and a humidity control instrument to cool, heat and humidify according to the given temperature and humidity. The temperature and humidity in the wet automatic switching box are digitally displayed by the instrument.
, working principle
Temperature control: When the temperature in the box is lower than the lower limit set value of the temperature controller, the temperature controller outputs a heating signal to instruct the electric heating element to start working. On the contrary, when the temperature is higher than the upper limit set value, the temperature control The instrument instructs the refrigeration system to automatically stop heating or cooling when the temperature inside the box reaches the required requirements.
Humidity control: The use of ultrasonic humidifier for humidification can ensure that the humidity in the box reaches %. The humidification device is automatically controlled by the temperature controller. When the humidity is < %, the temperature controller instructs the humidifier to automatically stop working after reaching the return difference value. The hysteresis value should be adjusted to -℃ to prevent it from being too large.
4. Instructions for use:
Place the box in place, adjust the level, and connect the ground wire. When it is stationary, add clean water to the water tank and the water level exceeds the heating pipe.
Open the door and take out the humidifier. Open the side door, place the humidifier on the upper tray, remove the transparent water tank, unscrew the water tank cover counterclockwise, and fill it with clean water (distilled water is best). After adding water, screw on the water tank cover and put it back into the main body of the humidifier. Then put the humidifier Press the nozzle of the humidifier and finally insert the humidifier plug into the socket in the side door. Turn on the power switch and adjust the spray knob to the maximum position. The temperature and humidity of the curing box temperature controller have been adjusted at the factory.
. Turn on the power and start the instrument to work. When the temperature and humidity in the box reaches a given value, put the specimen into the chamber. Heating and cooling are strictly prohibited at the same time.
5. Main matters:
The curing box should be used in a ventilated, dry, flat, non-corrosive environment. During daily use, pay attention to maintaining the water level of the water tank and humidifier to ensure normal use.
After the curing box is in place, it needs to be stationary for an hour before it can be powered on. The voltage must not be lower or higher than the voltage. Instability will burn out the controller. A regulated power supply must be used.
. The compressor cannot be started frequently for refrigeration work. If there is a power outage or stop, it must be started again every minute to avoid damaging the compressor.
Do not turn the equipment upside down to prevent the mixing of compressor lubricating oil and refrigerant from damaging the refrigeration unit.
, No inclination is allowed during transportation.
Conduct an insulation test before work to avoid the danger of leakage.
. The water added into the water tank is preferably ℃
6. Common faults and troubleshooting methods:
. The meter display does not work
The power is not connected. Check the fuse and plug.
Replace the power switch with a new one if it is broken.
The instrument output line has fallen off and the plug is not tightly plugged in.
If the contactor is burned out, replace it with a contactor of the same model.
, No cooling
Is the given value of the temperature controller correct? The temperature controller does not output a signal to adjust the given value or check the fuse of the temperature controller.
The output signal contactor of the temperature controller does not work. Replace the contactor.
Refrigerant leakage.
The compressor does not work. Connect the compressor to the power supply. If it still does not work, it means that the thermal relay or the compressor is burned out and must be replaced.
. The whole machine does not heat up
The temperature controller and contactor are burned out and need to be replaced.
If the heating tube is dehydrated and burned out, replace it with an electric heating element of the same power.
If the humidity in the box is lower than the given value, there will be no humidification.
Check whether the given value is correct and then turn the switch on the temperature controller to off to see if it sprays. If it does not spray, it means the humidifier is faulty.
When the digital display value is lower than the given value, does the humidity controller light turn red? If it does not change, the return difference value should be appropriately reduced and it turns red without humidification. Check the humidifier.
If the humidifier is not working properly, first check whether there is scale or impurities on the transducer. The transducer must be kept clean and then whether the water tank is cut off.
If the temperature controller cannot output a signal, check the temperature of the instrument. If it displays -%, it is not abnormal. Wipe off the water traces on the sensor probe with a dry cloth and the temperature will display normally.
If the magnetic tape is not tight, use heating to widen the magnetic tape (use a hair dryer).
If the box is leaking, use epoxy resin bonding or plastic welding.
7. Humidifier maintenance
When the humidifier is not in use, please turn off the power switch and unplug it.
. The humidifier must be cleaned when the following situations occur:
,) An unpleasant smell occurs.
,) The fog is normal but the fog cannot be sprayed out.
,) There is little or no fog.
, How to clean the humidifier
,) When cleaning, first remove the screw cap of the humidifier. Do not soak the humidifier in water.
,) Do not use detergent, alcohol or chemical polishes for glass furniture and do not use hot water exceeding ℃.
Contact number
"Concrete standard curing box"Related Products
Related categories
室内环保检测仪器 Meteorological instruments gas analyzer Chromatograph Rubber and plastic special instruments Test chamber and climate environment equipment Thermometers Pressure instrument biological instrument flow meter Mechanical measuring instruments Experimental equipment Measuring standard instruments valve sensor Measuring tools measuring instrument Weighing instrument Level instrument Display instrument Transmitter Environmental testing instruments Logger counter Industrial timer Control (regulating) instruments Actuator base instrument Testing Machine Analytical Instruments Optical Instruments Electrical instrumentation car instrument Non-destructive testing instruments Electronic measuring instruments Special instrumentation Instruments and accessories Pneumatic unit combination instrument Electric unit instrument cluster Instrument power supply Automated complete control system Centralized control device Inventory instrumentation Packaging testing equipment Second hand instruments Other uncategorized Disinfection machine VOC detection equipment Ray detection equipment Formaldehyde detection equipment Benzene detection equipment Ammonia gas detector Other indoor environmental testing instruments
Related Information
Long-term supply of high and low tempera CQL-150 ozone aging test chamber has pre 2016 Photovoltaic Solar Aging Test Chamb concrete curing box Shenzhen Demaxeng battery pack salt spra Demaisheng battery acupuncture test devi DMS capacitor pulse voltage test device Power battery pack low pressure simulati DMS-Battery Combustion Testing Machine DMS rapid temperature change constant te Shenzhen Demaxeng touch screen battery c Settlement volume 1~2mL/80cm2·h Salt w High and low temperature humidity and he How much does Shanghai Linpin LRHS-504-L Shanghai Linpin IoT teaching test box LR
Disclaimer

The information/pictures/parameters, etc. displayed on this webpage about【Concrete standard curing box】are provided by member【河北东胜建筑设备仪器厂 】,By Titker Trade Network members 【河北东胜建筑设备仪器厂 】is solely responsible for the authenticity, accuracy and legality of the information/pictures/parameters, etc.,Titker Trade Network only provides display services. For your safety, please choose Titker Trade Network for online trading, otherwise Titker Trade Network will not bear any responsibility for this.

If your legitimate rights and interests have been infringed, please contact Titker Trade Network customer service as soon as possible. We will serve you wholeheartedly. Thank you for your attention and support to Titker Trade Network!