. >High-definition microcirculation uses the unique technology of imported chips to magnify the blood vessels to make them clearer.
. Factory direct sales, large quantities of ready-made products shipped with purchase. The oil used in this instrument is cedar oil.
.
. dddd
. < ●Product usage:
<
< Portable microcirculation detector
It is an advanced medical optoelectronic instrument equipped with the latest microcirculation microscope, a dedicated high-brightness annular D light source, and a high-pixel color D digital camera. It is mainly used to study the microscopic dynamics of nail fold microcirculation capillaries at the end of human fingers. Fluoroscopic examination can dynamically and clearly display the shape of microcirculation blood vessels, blood flow status, and images around blood vessels in real time. This instrument is clinically used for early diagnosis, guiding treatment, and observing therapeutic effects of microcirculatory changes in various diseases (such as cardiovascular disease, diabetes, hypertension, stroke, rheumatoid arthritis, etc.). At the same time, it is widely used in many fields such as medicine, health products, human health consultation, census, beauty and health care, etc. It can be used by research institutions to carry out human microcirculation health examinations and can also be used by individuals to monitor their own microcirculation health. < < <: New color microcirculation detector
It is the latest product developed by our company. We have made great adjustments to the quality and hardware of the product. The light source uses a new D luminous lamp to avoid the previous problem of unstable voltage and easy breakage of the light source. Another thing is that the dedicated portable 1-inch display is a high-definition LCD screen with clearer and more detailed images. A bottle of special cedar oil is delivered and a set of teaching analysis materials. In addition, the optional computer connection conversion function can be used to save files for customers through the computer for review, etc. Bringing more convenience to your work. The instrument is equipped with a special aluminum alloy password box for easier carrying. It also comes with a special strap for easy carrying over the shoulder.
< < ●Product features:
< . Microvascular circulation can be observed within seconds. The operation is simple and fast. < , The microscopic image is stable, clear and does not shake. < , high-resolution microscope lens dedicated to microcirculation. < , Portable and ultra-lightweight design makes observation more mobile. < . It has a micro-focus wheel that can adjust the focus at will, making it more convenient to use. < , The built-in D cold light source of the lens accurately projects illumination on the target object. < , Use non-invasive methods to observe human blood microcirculation conditions in a timely manner.
< < ●Product configuration:
<, multiple times
<, achromatic objective lens times
effective working distance>
<, coaxial common rail coarse adjustment lifting range
Fine-tuning lifting range
< , Coaxial vertical and horizontal moving platform area>
Moving range>
< , It has a fine-tuning focusing wheel to adjust the focal length at will, making it more convenient to use. < , Long-life light source D. Circular>D
Ultra-white high-brightness light source (light source brightness steplessly adjustable)
. =
. < ●Microcirculation case analysis:
< >Hypertension
: The afferent branches are spasmodic, slender, and fishhook-shaped loops can be seen. The number of blood vessels is reduced and the blood flow speed is faster due to blood stasis. < >Coronary heart disease
: The number of vascular loops is reduced, the malformation of the output branch is severe, and the inferior venous plexus is expanded and blood stasis. Red blood cells aggregate, blood flow is slow, blood cells and plasma separate, and in severe cases, the blood flow becomes muddy. < >Hypotension shock
: The tube loops are hidden, flat, stiff, and the blood is pale and the blood flow is slow or stagnant. < >Chronic bronchitis, asthma, pulmonary heart disease
: The number of loops is reduced, the loops are short, or only the top of the loop is visible or disappears. Loop deformity [banned word] lower veins are dilated and the blood flow is slow. For senile chronic bronchitis, the tube loops are more normal but the inferior intermammary venous plexus is severely dilated. < >Diabetes
: The tube loops are blurred and deformed, the tube walls are not smooth, flocculent tube loops are common, blood viscosity is high, the flow rate is slow and sometimes appears as a dotted line. < >Liver disease
: The vascular loops are malformed, not smooth, have exudation or bleeding, serious red blood cell aggregation, and slow blood flow. In severe cases, the venous plexus is obvious. < >Peripheral vascular disease (vasculitis)
: reduced number of vascular loops, malformation, blood stasis on the top of the loops, exudation, or slow and uneven bleeding blood flow. < >Rheumatism
: The length of the tube loops is prolonged, spasms, and disappears, the arterial and venous pulses are significantly expanded, blood stasis, red blood cell aggregation, obvious thrombus, and slow flow rate. < >Kidney disease
: Pale background, exudation, bleeding, and blood stasis around the loops, unclear reduction in the number of loops, uneven thickness, tortuous and twisted loops, spasm at the arteriole end, and relative galloping at the venule end. Zhang, the flow rate slows down significantly. < >Arteriosclerosis
: The tube loops are deformed and twisted, and the tube walls are rough, twisted and cross-shaped. The blood viscosity is high and the blood flow is slow.
< < 3. How to use:
< ) Monitor switch to adjust the contrast to the highest level (turn clockwise) and adjust the brightness to mid-range and high (turn clockwise). ) Apply a little cedar oil (or paraffin oil) to the ring fingernail fold of the left hand, place it on the finger rest and align it below the objective lens. Rotate the microscope's coarse adjustment handwheel to adjust the focus until a clear image appears on the monitor screen. At the same time, it is better to adjust the contrast and brightness of the monitor appropriately so that it is not dazzling and the image is clear. (Note: The microscope focusing handwheel adopts the internationally advanced coaxial and common rail coarse and fine adjustment mechanism. When adjusting the focus, first rotate the coarse adjustment handwheel to find the image, and then use the fine adjustment handwheel to adjust the image until the image is clear. It is very convenient and easy to adjust the focus. If you find coarse adjustment, When the adjustment hand wheel is too loose or too tight, you can rotate the tension adjustment hand wheel and adjust it appropriately so that it does not slide down but can rise and fall freely.) < < 4. Maintenance and maintenance:
<. Place it in a cool, dry, dust-free, A place without acid, alkali and steam. < .The relative temperature in the air is less than %. < .If the temperature difference between the two places is large when moving, wait until the instrument adapts to the room temperature before installation and use to prevent the optical lenses from fogging and mold. < .The objective lens has been calibrated and cannot be disassembled by yourself. The dust on the mirror surface can be blown away with a blower or gently wiped off with a clean brush (or lens cleaning paper). < . If there is dust on the target surface of the camera, use absorbent cotton slightly dipped in xylene and gently wipe it. When wiping, gently rub from the center of the target surface outward. < . Care should be taken to avoid the objective lens being touched. <. Keep instrument surfaces clean.
< < 5. Precautions:
< ) Before use, check that the grid voltage should meet the % standard. < ) Cut off the power supply after use. < ) When replacing mercury lamps and halogen lamps, unplug the power cord and open the casing carefully to avoid damaging the lamp. < d) The power cord must use a three-phase socket and must be grounded for protection. < < 6. After-sales service:
<: The company's long-term after-sales service adheres to the customer's commitment: the host is guaranteed within one year (except for human factors) and the lifetime warranty protects the rights and interests of consumers to a greater extent