Type direct-reading D meter
Product Description
Biochemical oxygen demand D is a must-measure item for water quality evaluation and an important quality indicator for measuring the pollution of water quality by organic matter. The traditional determination method of D adopts chemical dilution method. This method is cumbersome to operate and requires high experimental skills of analysts. The large discreteness of experimental data often results in the inability to obtain accurate experimental results.
The direct-reading D meter is a new type of instrument that uses the air pressure difference method to measure biochemical oxygen demand. It is simple to operate and can provide accurate measurement results comparable to the chemical dilution method. It is intuitive to use and easy to maintain. It is widely used in environmental monitoring, petrochemical industry, medical and health, teaching and research and other departments to monitor water quality. It is a powerful tool for the majority of analysts.
Inject the water sample or pre-treated water sample into the culture bottle and put a carbon dioxide absorber () into the absorption cup at the mouth of the bottle. Then seal the culture bottle and place it in a biochemical incubator. When the sample to be tested is After five days of cultivation at a constant temperature of ℃, the water sample in the bottle undergoes a biological oxidation reaction at a certain stirring speed. Organic matter is converted into nitrogen, carbon and sulfur oxides and produces carbon dioxide gas, which is absorbed by sodium hydroxide. The oxygen in the upper space of the culture bottle continuously supplies the oxygen demand of the microorganisms in the water sample. A pressure difference is generated in the culture bottle and passes through the detection glass tube. The height of mercury in the water sample can be used to calculate the D value of the water sample within the specified measurement period.
Technical indicators:
, Ambient temperature: ℃ ~ ℃
, Measuring method: Differential pressure method
, Measuring range: /~/ (dilution is required when the D value exceeds the measuring range)
, Batch processing capacity: each water sample
, Accuracy: in line with national standards - standard regulations: the D value of glucose glutamate standard solution is within the range of /~/)
, Display: The sample D value (/) can be read directly from the pressure gauge scale
, culture temperature: ℃℃
, power supply: AC
, host size:
, host weight:
, power consumption: instrument
"DS-805 direct reading BOD5 meter"Related Products
Related categories
室内环保检测仪器 Meteorological instruments gas analyzer Chromatograph Rubber and plastic special instruments Test chamber and climate environment equipment Thermometers Pressure instrument biological instrument flow meter Mechanical measuring instruments Experimental equipment Measuring standard instruments valve sensor Measuring tools measuring instrument Weighing instrument Level instrument Display instrument Transmitter Environmental testing instruments Logger counter Industrial timer Control (regulating) instruments Actuator base instrument Testing Machine Analytical Instruments Optical Instruments Electrical instrumentation car instrument Non-destructive testing instruments Electronic measuring instruments Special instrumentation Instruments and accessories Pneumatic unit combination instrument Electric unit instrument cluster Instrument power supply Automated complete control system Centralized control device Inventory instrumentation Packaging testing equipment Second hand instruments Other uncategorized Disinfection machine VOC detection equipment Ray detection equipment Formaldehyde detection equipment Benzene detection equipment Ammonia gas detector Other indoor environmental testing instruments
Related Information
Dalian household gas alarm Panjin natural gas alarm Shenyang gas alarm manufacturer Environmentally friendly combustible gas Commonly used gas alarms Special acetylene alarm High performance carbon monoxide alarm Easy to use long tube combustible gas de Low price portable toxic gas detector Ideal Portable 4-in-1 Gas Detector Rest assured independent gas alarm High efficiency ammonia alarm Special portable gas detector Safety phosphine detector Commonly used sulfur dioxide detectors
Disclaimer

The information/pictures/parameters, etc. displayed on this webpage about【DS-805 direct reading BOD5 meter】are provided by member【Qingdao Dasen Environmental Protection Equipment Co., Ltd. 】,By Titker Trade Network members 【Qingdao Dasen Environmental Protection Equipment Co., Ltd. 】is solely responsible for the authenticity, accuracy and legality of the information/pictures/parameters, etc.,Titker Trade Network only provides display services. For your safety, please choose Titker Trade Network for online trading, otherwise Titker Trade Network will not bear any responsibility for this.

If your legitimate rights and interests have been infringed, please contact Titker Trade Network customer service as soon as possible. We will serve you wholeheartedly. Thank you for your attention and support to Titker Trade Network!

Titker Trade Network