- 35KW:
- 定制
- 35KW:
- 定制
- 35KW:
- 定制
Body. ■Three-phase inductive current and three-phase capacitive current values are directly and independently displayed on the control panel, and the resonance point symptoms are directly displayed on the panel.
Body. ■The minimum resolution of resistive load, inductive load and capacitive load is, which can accurately simulate the occurrence of AC resonance and meet the needs of inverter debugging and testing.
Body.■The resolution of three-phase inductive current and three-phase capacitive current values is.
Body. ■The power of three-phase resistive load, inductive load, and capacitive load can be independently controlled and adjusted by phase to accurately adjust the AC resonance point under the condition of unbalanced three-phase voltage.
Body.■ According to the performance parameter detection requirements, the corresponding power can be set through the operation panel or remote console, and the discharge power can be combined and set in any way.
Body. ■The host adopts electronic circuit control and has an automatic alarm protection function for temperature overheating. When overheating occurs due to special reasons, the load can be automatically cut off.
Body. Programmable load box AC load box load box
Body. ■Adopts LCD panel to display voltage, current value, power factor, frequency, active power, reactive power, etc. at the same time, and can also display voltage , current waveform. The measurement data can be uploaded to the machine and the process recording and storage function of the detection process data can be realized.
Body. ■New power consumption components, high power density, no red hot phenomenon, the whole machine consists of three parts: resistive load, inductive load and capacitive load.
Body. ■Power input adopts segmented switch control. The load works in an energy-consuming manner, and forced air cooling is used for heat dissipation.
Body.■Measurement data of the inspection process can be recorded and saved to the remote machine (control room).
Body.■ Equipped with background analysis software, measurement data can be exported into and formatted inspection reports.
Body.■Three-phase voltage and three-phase current have the value and minimum value automatic recording and storage function
Body.■The host has a voltage harmonic detection function, a current harmonic detection function, and can display in a histogram format Visual display of harmonic content.
Body.■Meet the performance testing needs of three-phase grid-connected inverters, and also meet the testing needs of single-phase low-power grid-connected inverters.
Body. ■The power load can be controlled and adjusted remotely (adjusted on the control room console), or the power can be directly controlled and adjusted on the host computer.
Body. ■Three-phase voltage imbalance can also accurately debug the occurrence of simulated resonance points and accurately detect the anti-islanding effect protection function of the grid-connected inverter.
Body. Programmable load box AC load box load box