Electrical fire monitoring detectors inside domestic electrical se

free member

New small digital rail electrical fire monitoring detector [supports function customization]

total supply
0
MOQ
0
brand
睿控科技
area
ZhejiangWenzhou city
Delivery period:
Shipped within 3 days from the date of payment by the buyer
Buyers are still looking
  • 1
  • 2
  • 3
Products Recommended

New small digital ra

Negotiable

Three-phase network

Negotiable

Wall-mounted fire mo

Negotiable

Digital electrical f

Negotiable

RFPM series fire equ

¥999.00/

Integrated electrica

Negotiable

Shop information

area:Zhejiang Wenzhou city

Member level:corporate memberYear1

identity:  

Already paid:0.00 yuan deposit

my badge: [Integrity File]

online service:

Business card

Yueqing Ruizhong Automation Technology Co

Applets
【Kind tips】When you call, please mention that you saw us on Titker Trade Network, thank you.
Product Details
Single-circuit electrical fire monitoring detector
< r/ />
One application scope
The series of split residual current electrical fire monitoring detectors are produced by our company in strict accordance with the national standard B "Residual Current Development and design of electrical fire monitoring detector. A new type of residual current electrical fire monitoring detector (hereinafter referred to as the monitor) is designed with reference to international advanced technology and developed according to the current situation of domestic power distribution network. This monitor is suitable for AC/, rated working voltage, and is widely used in unit power supply systems of high-rise residential buildings in high-risk warehouses and power systems in gas stations, hotels, and densely populated buildings. It can effectively ensure the safety and security of electricity use. Prevent the occurrence of electrical fires.
2. Structural Principle
The monitor is composed of a shell, button, display, input and output interface combined with a high-performance microprocessor core. Various sensors and input and output interfaces perform a series of complex actions such as signal acquisition, processing and control. Various real-time information and control signals of this product can be read and controlled on the host computer through R communication. The monitor obtains the current power grid information through the sensor, and submits it to the microprocessor for calculation, identification and judgment. After verification, it is sent to the control circuit, and at the same time, the information is sent to the host computer and display screen for the operator to observe.
Three working environments
Temperature: ℃~℃ Humidity %
Altitude (after exceeding it, it is necessary to reduce the capacity and reduce the rated current)
Environment: No conductive dust, non-corrosive and flammable The gas is not directly affected by thunderstorms, avoid strong direct sunlight, avoid rapid aging of the LCD screen, and stay away from strong magnetic field interference. The magnetic field strength in any direction should not exceed times of the geomagnetic field.
Four usage requirements
Before installing and using the product, you should first read the instruction manual of this product to understand the performance and working requirements of the product
Monitors without outer boxes should be installed by non-electrical professionals and Keep out of reach of minors
The wiring of the product should comply with the specifications. The terminal screws must be tightened and fixed and must not be loose
Each interface line must be ensured to be correct to prevent damage to internal components or other consequences when connected incorrectly. Loss
When installing, be careful not to let foreign objects fall into the monitor
The working power supply should meet the requirements and cannot exceed or fall below the limit value, otherwise the product will burn or fail to work properly
After installation, test run System, pay attention to errors and abnormal conditions
Conduct self-tests on the detector regularly to ensure its operating performance
Five main technical parameters
Project technical parameters
Working power supply
Display mode digital tube
Residual current alarm value~continuously adjustable
Temperature alarm value~℃ continuously adjustable
Alarm mode sound and light alarm
Communication mode R bR
Use Environment ℃~℃
Relative humidity %R (℃)
Altitude
Installation method: Drill holes in the cabinet or install on guide rails
Implement standard BB
Six dimensions diagram
< r/ />< r/ />
Eight terminal blocks description
< r/ />
< r/ />

Trip Output: Provide relay contact output when the system issues an alarm state
Communication: b RR communication data bus connection port
Fire linkage: Remote fire trip control
Temperature sensor: Digital temperature sensor ( Optional), which is the data input port of the sensor
Nine monitoring detectors and circuit breaker wiring diagram
< r/ />
< r/ />
< r/ />
< r/ />
< r/ />
Eleven Troubleshooting
Residual current alarm: First, check the records on the monitor to find and handle the relevant faults The reset button can be used to reset. After reset, the monitor can be closed only when it is running normally.
How to display unconnected: Unconnected means that the transformer is not connected. Check whether the transformer wiring is stable, eliminate disconnection and other faults, and then restart or self-test the detector.
With backlight but no display: Make sure the use environment is normal and not in a place exposed to high temperature and strong magnetic sunlight. Disconnect the tripper and restart the detector. If the problem persists, please contact the manufacturer for replacement.
No backlight and no display: First, check whether there is any foreign matter inside the product, whether there is a burning smell in the product itself, check the terminal connections, and check whether the power supply meets the requirements. If the problem still cannot be solved, please contact the manufacturer.
Note: The manufacturer will charge a certain maintenance fee for malfunctions caused by human factors such as improper operation.
Twelve Precautions
It is strictly prohibited to disassemble this monitor without permission, otherwise our company will have nothing to do with any consequences arising therefrom.
The use and installation of this monitor must be operated by professionals. Be sure to read this instruction carefully before operation.
After the circuit breaker is tripped by a detector, the cause must be investigated and the closing operation can be performed only after confirming and eliminating it
Be sure to distinguish between the ground wire and the neutral wire. In the monitoring circuit, the neutral wire must pass through the transformer.
When selecting a detector, attention should be paid to whether the technical parameters on the detector are consistent with the requirements of the actual application.
Periodically check to remove dust on the surface of the heat dissipation holes of the casing, pay attention to the connection status of the terminals, and maintain reliable insulation.
During use, storage and transportation, it must not be subject to rain erosion, sunlight exposure or violent impact, so as not to damage the stability and accuracy of the monitor.
The alarm setting value of the monitor should take into account the normal leakage value of the power distribution system and electrical equipment.

"New small digital rail electrical fire monitoring detector [supports function customization]"Related Products
Related categories
Security monitoring equipment Monitor transmission equipment Monitoring and recording equipment Locks Anti-theft alarm equipment Building intercom equipment 门禁考勤器材及系统 smart card Fire Equipment traffic safety facilities Traffic control management equipment Traffic detection equipment Static electricity tester smart transportation Home intelligence Security inspection equipment Explosion-proof equipment Anti-counterfeiting technology products Biometric technology equipment public address system Lightning protection equipment Anti-static products Information security products Military supplies and police equipment Work protection natural disaster protection Sports protective gear Self-defense gear life-saving equipment Inventory/second-hand security products Processing cooperation Other uncategorized
Related Information
Firefighting foam tank PHYM32/15 Ningxia PHYM vertical storage tank press PSY40 mobile fire water cannon manufactu Stainless steel safety exit sign luminou Black stainless steel bus sign, special pvc luminous floor stickers luminous fir Luminous Film Luminous Film High Brightn Stair anti-slip strips L-shaped stair an Tempered glass floor sticker with steel Stainless steel luminous floor stickers, 304 stainless steel luminous arrow scree Luminous floor stickers stainless steel Stair step evacuation instructions facad Tempered glass floor sticker with steel Tempered glass floor stickers for shoppi
Disclaimer

The information/pictures/parameters, etc. displayed on this webpage about【New small digital rail electrical fire monitoring detector [supports function customization]】are provided by member【Yueqing Ruizhong Automation Technology Co 】,By Titker Trade Network members 【Yueqing Ruizhong Automation Technology Co 】is solely responsible for the authenticity, accuracy and legality of the information/pictures/parameters, etc.,Titker Trade Network only provides display services. For your safety, please choose Titker Trade Network for online trading, otherwise Titker Trade Network will not bear any responsibility for this.