- 重量:
- 80kg
The hydraulic rail straightener is a special manual hydraulic tool for straightening (or bending) the rails on the line in the horizontal direction. The machine is lightweight and has simple operation. When in use, hook the rail straightener hook on the side of the rail head, push the piston top against the other side of the rail head, and then turn the eccentric handwheel to lock the rail straightener on the rail. At this time, tighten the oil drain valve and insert With a crowbar, you can perform straight rail work. After the operation is completed, loosen the oil drain valve, wait for the piston to retract, and then turn the eccentric handwheel in the opposite direction to lift the rail straightener from the rail. Before loading the pump oil, the installation status of the rail straightener on the rail must be checked. The rail straightener must be placed flat. The bottom surface of the hook must be close to the top surface of the rail. The hook and the eccentric wheels and piston tops at both ends must be in contact with both sides of the rail head. Good contact. When loading the pump oil, it is not easy to move too fast. Maintenance method: The oil must be kept clean. When the oil is found to be dirty, sticky or not flowing smoothly, the oil storage tank must be removed, and the oil circuit must be cleaned with detergent or pure industrial alcohol before adding clean No. 1 mechanical oil. .When disassembling and inspecting the oil suction valve, first unscrew the pump body, take out the sealing gasket and millimeter steel ball, and clean them. .When disassembling and inspecting the oil outlet valve, you can unscrew the millimeter hexagon socket screw at the bottom of the back cover, take out the steel ball and spring in sequence for cleaning. .When disassembling and inspecting the oil drain valve, you can unscrew the oil drain valve, and then take out the sealing rubber ring and steel ball for cleaning.
Main technical parameters
, Rated rail force of hydraulic rail device:
, Rail force of hydraulic rail device:
, Rail capacity of hydraulic rail device:/time< br/> . Working pressure of the hydraulic straightener system:
.Net weight
.Mechanical oil#
(1) Use
.During operation, hook the straightener hook On the side of the rail head, push the piston top against the other side of the rail head, then turn the eccentric handwheel to lock the rail straightener on the rail. At this time, tighten the oil drain valve and insert a crowbar in your hand to straighten the rail. Operation. After the operation is completed, loosen the oil drain valve, wait for the piston to retract, and then turn the eccentric handwheel in the opposite direction to lift the rail straightener from the rail.
.Before loading the pump oil, it is necessary to check the placement status of the straight rail device on the rail. The straight rail device must be placed flat, the ground of the hook must be close to the top surface of the rail, and the hook and the eccentric wheels and piston heads at both ends must be Good contact with both sides of rail head.
. When loading pump oil, the action should not be too fast. When unloading, the eccentric handwheel must be turned only after the piston head leaves the side of the rail head. During the operation, do not turn the eccentric handwheel.
.When the piston stroke reaches the maximum value, the return spring in the cylinder is in a compressed state. In order to avoid malfunction, the piston stroke should not be greater than the maximum value during use.
.The double oil drain valve is a safety protection device and must be kept in good condition. If one oil drain valve fails during operation and the piston cannot be reset, the other oil drain valve can be opened to unload. During operation, it is advisable to use a fixed oil drain valve.
.When operating in areas with serious vertical wear on the side of the rail, oblique iron plugs must be added to the worn areas.
. The straight rail device cannot be placed in the center of the road to ensure safety.
(2) Maintenance
. The oil must be kept clean. When the oil is found to be dirty, sticky or has poor oil absorption, the oil storage tank must be removed and the oil circuit must be cleaned with detergent or pure industrial alcohol. Refill with clean machine oil.
.When disassembling and inspecting the oil suction valve, first unscrew the pump body, take out the sealing gasket and the diameter of the steel ball, and clean and inspect them.
.When disassembling and inspecting the oil outlet valve, you can unscrew the hexagonal socket screw at the bottom of the back cover, take out the diameter steel ball, spring and diameter steel ball in sequence for cleaning and inspection.
.When disassembling and inspecting the oil drain valve, you can unscrew the oil drain valve, then take out the sealing rubber ring and diameter steel ball for cleaning and inspection.
When the straight rail device is fully disassembled and inspected, the sequence is as follows:
Remove the connecting pin between the pressing handle and the plunger pump core, and use two special wrenches to unscrew the back cover.
Use a special wrench to loosen the nut of the clamping cylinder, and then use the pressing hand to compress the piston. Then you can unscrew the screw between the top and the piston, remove the top, then loosen the pressing hand, and take out the piston and original spring. . Then unscrew the nut and the cylinder can be extracted.
The plunger pump core is only allowed to be installed or taken out from the lower end of the pump body. The piston group is only allowed to be installed or taken out from the connection end between the oil cylinder and the back cover.
Check each seal and steel ball. If there is any damage, replace it with a new one (the steel ball should be of first-class accuracy)
Jining Shunyuan Industrial and Mining Equipment Co., Ltd., established in 2001, specializes in the production of hydraulic linear rails with first-class quality ,cheap price. Welcome to call us for consultation and purchase!
Contact person: Gao Jing
Telephone: