c=Use introduction:
& Origin: Hong Kong.
& Used to measure the irradiation energy value of different light sources within a certain period of time, which is commonly referred to as light performance
& With the continuous improvement of users’ requirements for UV curing, energy meters have become a part of the production process It is an extremely important curing quality monitoring instrument and is an essential tool to well control and achieve product curing quality consistency
&The measured spectral range is (nanometer), and the optimal sensing ultraviolet wavelength is (nanometer)
Technical data
Spectral range: && (nanometer)
Light intensity range: no limit
Measuring range: &/c (millijoules/cm2)
Power supply used: Battery
Battery power consumption:
Battery life: one year under normal operating conditions
Dimensions: *&*(mm)
Weight: (g)
Environment Temperature: to ℃ (Celsius)
Withstand temperature: Continuous irradiation does not exceed (seconds) under the condition of ℃ (Celsius)
Measurement accuracy: &%
Calibration cycle: to accurately ensure measurement accuracy and effect, the recommended verification period is one year.
Warranty period: Warranty within one year from the date of purchase, except for damage caused by human damage or objective factors.
c=&Instructions for use:
& Turn the switch above the energy meter to the on position, that is, the &&r position. At this time, the number &&r&/c (millijoules/square) will be displayed on the display. centimeter).
& Prepare to measure, face the back of the energy meter towards the ultraviolet light source to ensure the effectiveness and accuracy of the measurement. The photosensitive window is clearly marked.
When the instrument has been exposed to the light source for a certain period of time, it has recorded the sensed ultraviolet light energy. At this time, the energy value can be read from the display on the front of the instrument. The corresponding unit of the energy value is: /c (millimeter) joules/cm²).
Every time, when performing a new measurement, turn the instrument off and on again as needed. The display will readjust to &&r&/c (millijoules/cm2). You can then continue by following the steps above.
&Every time you use it, please turn the switch of the instrument to the on state, that is, the &&r position. The reading displayed on the LCD screen is &&r/c (millijoules/square centimeter). If you do not want to obtain the cumulative results of repeated tests, Energy value, please reset its reading to zero before each measurement.
& If your process requires it, you can also perform measurements repeatedly. The reading after each measurement does not need to be reset to zero. Then, the last reading displayed on the instrument will be the cumulative value of multiple repeated measurements. .
When the measurement is completed, the switch needs to be adjusted to the &&r position to turn off the instrument in time. Correct operation will effectively ensure the battery life of the instrument.
c=Note:
Please avoid shaking the instrument frequently or breaking it
After each measurement, please close the instrument in time and put it back in the box for storage
br/> When measuring, please avoid placing the LCD screen on the front of the instrument directly in a strong light or high heat environment.
Non-professionals should not open the instrument for adjustment or damage by themselves, as this will affect the detection effect and accuracy of the instrument.
c=
&
&&The energy meter is our company’s new patented product. Its compact, beautiful and lightweight design makes it easier for users to carry
&Due to the use of high-precision, micro-imported components, the overall appearance size of the instrument Very small. For the objects being inspected, the size requirements are lower and the flexibility during inspection is greater. For example, it is suitable for large production lines, multi-dimensional three-dimensional light source systems, and precise, compact low-power light sources
&Appearance It has a square structure, that is, a square energy meter, and its appearance is exquisite, beautiful, and generous