- 保护高度:
- 50-3200mm
- 保护区域:
- 1-2-3-5-10m
- 输出控制:
- NPN/PNP输出,继电器输出控制
Infrared protector selection: safety light curtain
1. Determine the protection range area and model according to your own protection requirements
The protection range areas are: m, m, m, m,
The following optical axis spacing accuracy selection
, mm optical axis spacing, suitable for fingers or others, protective area mm, mm, m
, mm optical axis spacing, generally suitable for protecting fingers, protective range area mm , mm, mm, m
, mm optical axis spacing, generally used to protect fingers and palms, protection range area mm,, m
, mm optical axis spacing, generally used to protect palms, protection range mm ,, mm, mm, m
, mm optical axis spacing, used to protect the arm, protection range mm, mm, mm, mm, m
, mm optical axis spacing, used to protect the body or large objects Object, protection range mm, mm, mm, m
2. Protect the height area according to the needs, that is, the dangerous area needs to be protected. The protection area protection height is mmmm. Other heights can be customized
3. Select the optical axis according to the protection requirements The spacing size requires the optical axis spacing to be selected in mm, mm, mm, mm, mm, m
4. Select the control output mode: safety grating with controller or without controller
With controller, it is a relay Output, working power supply/, directly connected to the electrical control circuit
/ Output, working power supply: D only needs to provide high and low level control output signals to the machine or control board circuit
, with self-detection function
When power is on, self-test is implemented to ensure that there is no fault
and safety blind zone self-test function
When an object blocks the light curtain, the output of the photoelectric protector is always a disconnect signal, and the machine will not accidentally Start operation to make production safer and more reliable
Synchronization technology
Synchronization technology replaces traditional data line synchronization to avoid signal interference and eliminate long data line connections
Working principle
The infrared protector forms a safe area protection by the transmitter and receiver. When the protected area is blocked, the protector generates a shading signal, which is transmitted to the controller through a signal cable. The controller may process the signal and generate a control output signal to control the machine's brake control circuit or an alarm signal for other equipment. , to achieve machine stop operation or safety alarm
Technical parameters
Power supply: /HZ
Relay output: Equipped with controller (equipped with an external controller to control a set of machine tool protection devices, built-in control The controller can control one set of machine tool protection devices, a dual-loop external controller can control two pairs of machine tool protection devices, and a three-loop controller can control three pairs of machine protection devices. Other multi-loop controllers can be customized to control multiple sets of machine protection devices)
/Output power supply D//Output