Product Details
Fujian Province Chimney Installation Lightning Rod Company Lightning Network System Manufacturer Inspection Unit
Chimney Installation Hoop Reinforcement Replacement Lightning Rod Maintenance Construction Company Manufacturer Unit
Fujian Province Fuzhou Chimney Reinforcement Hoop Construction Company, Putian Quanzhou Chimney Repair Lightning Rod Company, Xiamen Zhangzhou chimney installation lightning rod construction company, Longyan Sanming chimney installation lightning protection and lightning protection system engineering construction manufacturer, Nanping
Ningde
chimney ladder platform maintenance anti-corrosion and welding construction manufacturer, chimney vertical ladder installation cage protection net construction company.
, Construction unit Anhui Hefei Thermal Power Co., Ltd.
, Construction unit Jiangsu Jinfeng High-altitude Construction and Anti-corrosion Engineering Co., Ltd.
, Project name m reinforced concrete chimney installation lightning protection system ladder platform reinforcement and welding anti-corrosion project
, Construction location: In the courtyard of Anhui Hefei Thermal Power Co., Ltd.
, Project manager Liu Jie
Xin
Technical consulting
, Project scope: meters reinforced concrete chimney installation The lightning protection system ladder platform reinforcement, welding and anti-corrosion project, the specific project quantities are as follows (can be determined based on the completed drawings, and the calculation error will not be adjusted within the scope).
Reinforced concrete chimney installation lightning protection system ladder platform reinforcement, welding and anti-corrosion project
Construction plan
Meter chimney installation lightning protection system ladder platform reinforcement, welding and anti-corrosion project Construction plan preparation basis
This project "Construction Organization Design"
"Reinforced Concrete Chimney Design Drawings"
"Construction Quality Acceptance Specifications and Assessment Procedures for Electric Power Construction" (Civil Engineering Section/)
"Chimney Engineering Construction and Acceptance Specifications"
/> "Building Construction Manual"
"Construction Engineering Project Management Specifications"
"Building Construction Safety Inspection Standards"
"Technical Regulations for Temporary Electricity Safety at Construction Sites"
"Construction Machinery Safety Regulations for Use"
"Safety Technical Specifications for Fastener Steel Pipe Scaffolding in Construction"
"Construction Quality Acceptance Specifications for Building Foundation Foundation Projects"
Our company's relevant quality, technology, safety, civilized construction, etc. Documents
Other relevant standards, specifications, documents, etc.
This project is a lightning rod installation and maintenance project for two brick chimneys of Xinhua Chemical Co., Ltd. The chimney of this project is high and it is a high-rise building. Due to age, disrepair, smoke weathering, corrosion from sulfur dioxide and other mixtures, the chimney lightning rods and other materials have corroded and rotted. The down conductor was seriously corroded. The construction height of this project is high and difficult. Among them, the clay brick roof at the top of the chimney has been severely corroded and loosened. It is impossible to fix the lightning rod. In addition, the temperature at the chimney outlet is nearly 100 degrees. It is necessary to add hoops to reinforce it, and add two wraps to the top. The hoop fixed lightning rod must be repaired while ensuring safe production and the same safety of construction personnel. Our company has a group of professional chimney maintenance and construction teams with rich theoretical and practical experience, excellent skills, and hard-fighting. Whether it is operation management or All high-altitude construction techniques can be used to meet the needs of this project.
Construction technical requirements
Regarding the installation and construction of lightning rods for opposite chimneys, strictly follow the technical specifications for electric power construction and acceptance "Boiler Unit Electrical Chapter"/, and the grounding rectification shall be in accordance with "Construction of Grounding Devices for Electrical Installation Projects" and Acceptance Specifications" When dismantling all old objects on the stack, they must be tied up with ropes before dismantling can begin, and then transported vertically to the ground with ropes to prevent injuries to others and equipment from falling objects from high altitudes. All construction materials are not allowed to be reused. If there are special reasons, they must be confirmed and approved by Party A, otherwise they will be regarded as reworked by Party B. The lightning rod is made of stainless steel elements and materials, and all welding points must be fully welded. The hoop that fixes the lightning rod is made of stainless steel flat steel hoop. The bottom grounding down conductor was rectified and buried in the soil, and some stainless steel materials were used to connect the stainless steel flat steel punched gong bolts of the ground down conductor to facilitate inspection and maintenance. Installation and construction, civilized construction and environmental protection requirements. This project is characterized by a short construction period, a single major, high quality and process requirements, a special grade for high-altitude operations, and a high construction wind inspection grade. To this end, measures have been formulated.
Adhering to the principle of safety first and zero accidents, Party A’s various safety regulations and measures should be strictly observed. Obey the safety supervision of safety management personnel, prevent violations and prevent accidents.
During the construction process, all construction workers must wear safety helmets, safety belts, and dust masks. All high-altitude workers must hold a high-altitude suspension operation certificate issued by the State Administration of Work Safety to work. It is strictly prohibited to participate in operations while sick, drunk, tired, or depressed. The construction site must have security or protective nets in place, various on-site safety measures must be taken, and a dedicated person should be assigned to supervise the placement of on-site equipment and materials. All fire protection facilities must be in good condition, clearly marked, neat and orderly, and standards of civilized production at the construction site must be met. and requirements.
Jinfeng High-altitude Engineering Qualifications
First-level Safety Production License
Professional contracting of high-altitude work projects
Professional contracting of high-altitude structure projects
Professional contracting of mechanical and electrical equipment installation projects
/> Professional contracting of anti-corrosion and thermal insulation projects
Professional contracting of building waterproofing projects
Each construction employee has a high-altitude work certificate, an electrician certificate, an oxygen welder certificate, and an accidental injury insurance policy, with the relevant certificate number and The ID numbers are the same.
Jiangsu Jinfeng High-altitude Construction and Anti-Corrosion Engineering Co., Ltd.
Address, Xindu Road, Yancheng City, Jiangsu Province
Postal Code
Telephone
Fax
Project Manager Liu Jiexin
/> Mobile phone
Disclaimer
The information/pictures/parameters, etc. displayed on this webpage about【Fujian Province Chimney Installation Lightning Rod Company Lightning Network System Manufacturer Inspection Unit】are provided by member【Jiangsu Jinfeng Aerial Engineering Co
】,By Titker Trade Network members 【Jiangsu Jinfeng Aerial Engineering Co
】is solely responsible for the authenticity, accuracy and legality of the information/pictures/parameters, etc.,Titker Trade Network only provides display services. For your safety, please choose Titker Trade Network for online trading, otherwise Titker Trade Network will not bear any responsibility for this.
If your legitimate rights and interests have been infringed, please contact Titker Trade Network customer service as soon as possible. We will serve you wholeheartedly. Thank you for your attention and support to Titker Trade Network!