Product Details
1.
Product Features
The advanced full-function elderly caregiver model is designed based on the physiological characteristics of the elderly and specifically for clinical nursing training operations and internship requirements. It was developed by Shanghai Zhonghong Company after discussion by experts. The latest products developed.
This product combines the main functions of basic care and surgical care. The complete set of products consists of a full-body geriatric care simulator and a non-invasive blood pressure measurement simulator. This model is made of imported plastic materials through mold casting technology. It has the characteristics of lifelike image, realistic operation, convenient disassembly and assembly, reasonable structure and durability. It can also be disassembled and assembled into parts for local functional teaching training. It allows nursing workers to understand and care more about the elderly during the elderly care process.
2.
Product functions
,
Head care, shampooing, face washing
,
Pupillary observation
,
Eye, Ear drops cleaning, hearing aid removal and insertion
,
Oral care, denture care
,
Oral and nasotracheal intubation
,
Tracheotomy Nursing
,
Sputum suction method
,
Oxygen inhalation method
,
Oral and nasogastric feeding method
, Gastric lavage method
, Observation of the structure of important organs in the anatomy of the chest
, arm venipuncture, injection, infusion, blood transfusion training
, subcutaneous injection of deltoid muscle
, intramuscular injection of vastus lateralis
, intramuscular injection of buttocks
br/>, chest, bone marrow and lumbar puncture
, enema
, male/female catheterization
, male/female bladder irrigation
, ostomy drainage
> , colostomy
, pressure ulcer (decubitus) care (four different stages of sacral decubitus modules)
, overall care scrubbing, dressing and changing, hot and cold therapy
, limb joints Realistic, simulates joint stiffness, the trunk can lean forward, and you can sit in a wheelchair
, non-invasive blood pressure measurement (Appendix Non-invasive blood pressure measurement manual)
3.
Usage
Arm venipuncture , injection, infusion (blood transfusion)
The arm venipuncture model consists of a plastic upper limb arm showing the cubital and forearm veins (cephalic vein and basilic vein) and infusion blood vessels and other supporting devices. It is the most common teaching method for clinical basic nursing practice operations. One of the models.
Training items
1. Blood extraction through cubital forearm vein
2. Transcubital forearm vein injection or intravenous infusion
3. Transcubital forearm vein blood transfusion
4. Upper arm Lateral deltoid intramuscular injection
Installation method
Put the two rubber tube clamps on the two rubber tubes connected to the plastic upper limb model. One rubber tube goes up and is connected to the blood simulation fluid through the connecting sleeve. The infusion bag (bottle) is connected. The other rubber tube goes down and into the exhaust fluid bottle.
Teaching steps
1. Draw blood through the cubital and forearm veins
Venous blood drawing operation training
Step 1. Connect the ml of blood simulation solution to the upper rubber tube of the plastic upper limb model to make the blood The simulation fluid is injected into and fills the pipe system in the rubber upper limb model, and the lower rubber pipe clamp is clamped to block the lower rubber pipe.
Step 2: Routinely disinfect the skin of the elbow and forearm.
Step 3: Select a suitable vein, puncture the vein with a ml syringe, and draw ml of venous blood (blood simulation fluid).
2. Intravenous injection or intravenous infusion through the elbow and forearm
In intravenous injection or intravenous infusion, the medicinal solution is pressurized and injected into the vein. Commonly used veins include the cephalic vein and the basilic vein.
Use to rescue or treat patients. Glucose solution and medicinal solution or blood are injected into the patient through intravenous pressure to increase the blood volume of the coronary arteries and carotid arteries, thereby improving the blood flow in the heart and brain. The blood pressure is raised through reflex to rescue or treat the patient. Used to perform certain special inspections, etc. Used for chemotherapy.
Intravenous injection or intravenous infusion operation training
The steps are the same as those of drawing blood through the cubital and forearm veins, using injection trays, appropriate syringes, needles, drugs, abrasive belts, sterile gloves and sterile treatment towels, etc. . Patients with hematological diseases are contraindicated in this method of injection to avoid excessive bleeding.
Steps: Routinely disinfect the skin of the elbow and forearm, wear sterile gloves, and lay down sterile drape.
Steps: Use the index and middle fingers of your left hand to fix the selected vein, and use the other hand to draw a syringe containing the medicinal solution (the syringe and needle are inserted vertically into the vein or at an angle to the vein. When the needle is drawn back, red liquid will enter. When using a syringe, clamp the upper rubber tube clamp to block the upper rubber tube, loosen the lower rubber tube clamp, fix the puncture needle with one hand, and at the same time use the other hand to push the medicine liquid as fast as possible to make the medicine in the syringe The liquid passes through the pipeline system in the model, and the liquid enters the waste gas liquid bottle through the lower rubber tube. After the injection is completed, quickly pull out the needle. During intravenous injection, when the vein is withdrawn and red liquid is seen entering the syringe, loosen the upper rubber Use the pipe clamp to adjust the intravenous drip speed so that the red blood simulated liquid in the bottle passes through the pipe system in the model and enters the waste gas liquid bottle through the lower rubber tube, and fix the puncture needle.
3. Blood transfusion through cubital and forearm veins
Intravenous blood transfusion operation training
Steps to draw blood through the elbow and forearm veins
Step 2: Routinely disinfect the elbow and forearm skin.
Step 3: Select a suitable vein, puncture the vein with an injection needle, After withdrawing and seeing that the red liquid has entered, adjust the drip speed of the intravenous blood transfusion device so that the red blood simulation liquid in the infusion bottle flows through the pipeline system in the model and enters the waste gas liquid bottle through the lower rubber tube.
4. Triangle on the outside of the upper arm Intramuscular injection
Steps: Use a syringe to remove the drug solution
Steps: Select a suitable site for injection in the deltoid muscle on the lateral side of the upper arm, and routinely disinfect the skin at the injection site.
Steps: Puncture the syringe needle through the skin In the deltoid muscle, slowly inject the liquid into the muscle.
Chest and abdominal puncture training includes lumbar puncture of the chest, liver, and bone marrow
①Thoracentesis (the midaxillary line is on the ground ~ the intercostals and the anterior axillary line are on the ground) Intercostal. The puncture needle is inserted vertically along the upper edge of the lower rib, and the liquid is injected into the puncture bottle first)
② Liver puncture (in the right mid-axillary line, the first ~ intercostal space, the depth does not exceed the depth, and the liquid is injected before puncture) Liquid into the puncture bottle)
③ Bone marrow puncture (out behind the left superior iliac spine)
④ Lumbar puncture (in the space of the spinous process of the lumbar vertebrae, the depth is about 100% for adults, and the highest point of the iliac crest is level with the iliac crest) Lumbar spinous process, inject liquid into the puncture bottle before puncture).
4. Blood pressure measurement practice (functional features)
, blood pressure measurement training mode and assessment mode, systolic blood pressure, diastolic blood pressure and heart rate parameters can be Self-setting
, technical indicators ①Set the systolic blood pressure range ②Set the diastolic blood pressure range ③Heart rate setting range beats/minute
Note
①Production parameter setting
Systolic blood pressure and diastolic pressure Heart rate beats/min
② When the systolic blood pressure set value is less than or equal to the diastolic blood pressure set value, the system will issue an alarm.
. The auscultation interval can be set to simulate special illnesses.
①Auscultation The upper limit of systolic blood pressure is not greater than the current set value
②The lower limit of auscultation diastolic pressure is not less than the current set value+
, real-time blood pressure measurement and display by cuff pressurization method
①Cuff pressure measurement range ~
②The cuff pressure can be corrected
, the deflation speed is checked and alarmed during the measurement process. When the deflation speed is /H, the buzzer will alarm.
, shortcut keys
For ease of use, this product is preset with a group of shortcut keys.
① Press the Settings and keys simultaneously for the pressure correction shortcut key to directly enter the pressure correction interface.
②Restore factory parameters Press the Set and + keys at the same time to restore factory parameters. During use, if there are obstacles such as garbled characters or inability to set parameters due to misoperation or electromagnetic interference, you can use this shortcut key to restore it.
③Training/assessment mode switching Press the + and keys at the same time to switch freely between training or assessment mode
Korotkoff sounds are played during real blood pressure measurement, and external headphones or active speakers can be connected.
Note that headphones or speakers are optional
Automatic shutdown When the training device is not used for several minutes, the system will automatically shut down.
Flexible power supply options use an external power adapter or a battery.
6. Blood pressure measurement training mode and assessment mode
Blood pressure measurement training mode
Instructions for use
⑴ Connect the arm model to the training device and set the systolic blood pressure, diastolic blood pressure and heart rate values.
Note that during use, if you find that the pressure value measured by the training device deviates greatly from the pressure gauge pointer reading, please perform pressure correction to ensure the accuracy of training.
⑵ Place the arm model horizontally, palms up, and place the blood pressure monitor flat on the table. Drain the remaining air in the cuff and wrap it flatly around a centimeter above the elbow joint. It should be tight enough to fit one finger. .
⑶ Put on the stethoscope, place the stethoscope head close to the brachial artery on the inner side of the upper arm above the elbow joint, close the air valve tightly, hold the hand ball and inflate the cuff to the left and right (diastolic pressure for normal people
Then slowly open the air valve Deflate and let the pointer drop slowly. When you hear the first loud pulsation sound in the stethoscope, the scale indicated by the blood pressure meter pointer represents the retraction pressure. Continue to deflate, the pulsation sound continues to exist and amplifies, and when the pulsation sound suddenly disappears , the scale indicated by the pointer at this time represents the diastolic pressure.
*If you cannot hear clearly, you can lower the pointer to the position and re-measure.
*If you hear it immediately after the first pressurization, If you hear Korotkoff sounds, please re-pressurize appropriately for measurement. It is suitable for hypertension.
*During the deflation measurement process, if the deflation speed is too fast, the training device will alarm.
*During the measurement process , if the Korotkoff sound is not obvious or the sound is low, please confirm whether the stethoscope head is placed correctly
* During the measurement process, the deflation speed is controlled at / to make the measurement results accurate
⑷ After the measurement, drain the sleeve With the remaining air in the band, tighten the valve, untie the cuff, arrange it properly, and put it into the box.
Pressure measurement assessment mode
Instructions for use
① First perform pressure correction (see pressure correction method)
②Then set the systolic blood pressure, diastolic blood pressure and heart rate values.
③Finally press the + and keys at the same time. At this time, the training device will enter the assessment mode, the main parameter values on the screen will be hidden, and the keyboard is locked and cannot perform single-key operations (excluding shortcut keys).
④The blood pressure measurement method in assessment mode is the same as the measurement method in training mode
⑤Compare the systolic blood pressure and diastolic blood pressure values measured by the student with the settings Compare with fixed values to assess students’ performance.
⑥After the assessment, the user presses the + and keys simultaneously again to switch to the training mode, and the originally set parameter values will be re-displayed.
7. Scope of application
, suitable for clinical teaching and practical training of students in medical schools, nursing schools, occupational health institutes, etc.
, continuing education of hospital medical staff, clinical teaching and practical training
, clinical practice in grassroots health units Medical popularization training
8. Maintenance, warranty
After functional operation training such as nasogastric feeding, gastric lavage, enema, male and female catheterization, etc., it is necessary to empty the remaining night that was injected into the stomach, intestines, and bladder during the operation.
. When not using it for a long time, the model should be wiped clean, packaged and stored in a cool and dry place to extend its service life.
. Insufficient battery voltage will cause the Korotkoff sound to not be played or distorted, please promptly Replace the battery.
If the battery is not used for a long time, please take it out in time to avoid leakage.
The model is assembled, keep the nuts during disassembly and assembly, and spare parts are available for replacement.
/> . If this model has any quality problems due to manufacturing process or original parts (except for human-caused problems) within one year of the date of purchase or the warranty period stipulated in the contract, our company will be responsible for free maintenance services. It also promises lifelong maintenance at the user's own expense.
Disclaimer
The information/pictures/parameters, etc. displayed on this webpage about【Advanced full-function male elderly care model, ZH/220A elderly care model】are provided by member【Shanghai Zhonghong Science and Education Equipment Co
】,By Titker Trade Network members 【Shanghai Zhonghong Science and Education Equipment Co
】is solely responsible for the authenticity, accuracy and legality of the information/pictures/parameters, etc.,Titker Trade Network only provides display services. For your safety, please choose Titker Trade Network for online trading, otherwise Titker Trade Network will not bear any responsibility for this.
If your legitimate rights and interests have been infringed, please contact Titker Trade Network customer service as soon as possible. We will serve you wholeheartedly. Thank you for your attention and support to Titker Trade Network!