- 分辨率测量对象:
- 可燃气体,有毒气体
- 尺寸:
- RBK-6000-2-H:250*240*90 ≤3.5Kg
- 电压:
- AC220V±10%
Technical indicators of chlorine leak alarm
◆Working voltage
◆Measurement range~
◆Detect gas flammable gas (natural gas, liquefied gas, hydrogen, acetylene, etc.), flammable gas Liquids (benzenes, alcohols, ketones, esters, etc.)
◆Detection principle catalytic combustion type
◆Alarm output normally open
◆Alarm volume
◆Response time
/> ◆Recovery time
◆Power consumption/channel
◆Measurement error
◆Explosion-proof level II
◆Electrical interface/
◆Using temperature ℃~+℃
◆Using humidity
◆Power backup time
Chlorine leak alarm product features
Using a high-speed processor, it can handle system tasks quickly and accurately to ensure system reliability
LCD The screen can display the concentration and status of the detector in real time
Using communication protocol, high reliability
Set of programmable relays, passive normally open and normally closed contacts, contact capacity/
Adopted Modular structure design facilitates system maintenance
Local monitoring can be achieved through a computer, and detector operation status data can be permanently stored
Technical parameters of intelligent chlorine alarm controller
Matched with advanced gas detectors Use
Working voltage
Use temperature ℃~℃
Use humidity
LCD screen display/
Alarm system sound and light alarm
Alarm volume
Transmission Distance
Volume
We all know that chlorine is a highly dangerous chemical. Chlorine leakage can cause serious harm to the human body and is also flammable and explosive to a certain extent. Therefore, enterprises must pay attention to storage to avoid major accidents caused by improper storage of chlorine. Today, the chlorine toxic gas detector will answer some questions you need to pay attention to when storing liquid chlorine!
Storage safety of liquid chlorine cylinders
Gas cylinders should not be stored in the open air, nor should they be stored on scaffolds built with flammable or combustible materials. They should be stored in a dedicated warehouse.
Empty bottles and filled heavy bottles should be placed separately and should not be mixed with other gas bottles. Other dangerous items should not be stored in the same room.
The storage period of heavy bottles should not exceed three months.
Heavy bottles with a filling capacity of 100,000 and 100,000, should be placed horizontally to prevent rolling, and a lifting distance and passage should be left. Storage height should not exceed two levels.
Storage safety of the second liquid chlorine storage tank
Flammable and combustible items should not be stacked within the storage tank area.
The liquid chlorine outlet pipeline of large-capacity liquid chlorine storage tanks should be equipped with flexible connections or spring supports and hangers to prevent installation stress caused by foundation sinking.
Safety signs should be installed within the tank storage area, and corresponding emergency repair equipment, effective protective equipment and fire-fighting equipment should be equipped.
The floor of the above-ground liquid chlorine storage tank area should be lower than the surrounding ground, or accident cofferdams should be set up around the storage area to prevent the expansion of the liquid chlorine gasification area in the event of a liquid chlorine leakage
Summer is a time of various In the season where gas accidents occur frequently, the high levels in summer provide convenient conditions for the volatilization of chlorine. You need to pay more attention when storing liquid chlorine. Install a chlorine toxic gas detector in the storage place to monitor the concentration of chlorine in the storage place. Once it reaches a hazardous concentration The detector alarms, reminding staff to take appropriate measures in time to avoid major accidents!
Chlorine leak alarm, chlorine alarm controller professional manufacturer specializes in production, portable chlorine alarm, handheld chlorine leak alarm , chlorine detection alarm, chlorine leak detector, chlorine leak detector, chlorine detector, chlorine concentration alarm chlorine detector toxic gas alarm, products are sold to Shandong Jiangsu Jiangxi Hebei Henan Zhejiang Liaoning Tianjin Dalian Xinjiang Gansu Sichuan Guangdong Guangxi Anhui, Fujian, Hubei, Hunan, Chongqing, Yunnan, Ningxia, Inner Mongolia, Jilin, Shanghai, Guizhou, Shaanxi, Shanxi and other parts of the country.
Chlorine leak alarms are composed of detectors and alarm control hosts. They are widely used in petrochemical industries such as petroleum, gas, chemical industry, and oil depots where toxic gases exist to detect leaks in indoor and outdoor dangerous places. , is an important instrument to ensure production and personal safety. When toxic gas exists in the measured site, the detector converts the gas signal into a voltage signal or current signal and transmits it to the alarm instrument. The instrument displays the percentage concentration value of the lower explosion limit of the toxic gas. When the concentration of toxic gases exceeds the alarm set value, an audible and visual alarm signal will occur, and the personnel on duty will take safety measures in time to avoid explosion accidents.
The chlorine toxic gas detector is an important security equipment for detecting the concentration of chlorine leakage. The most important part of it is that the gas sensor adopts the electrochemical working principle! The electrochemical sensor reacts with the measured gas and It works by generating an electrical signal proportional to the gas concentration. A typical electrochemical sensor consists of a sensing electrode (or working electrode) and a counter electrode, separated by a thin electrolytic layer.
The working principle of the chlorine leak alarm is that through an electrochemical sensor and a resistor connected between the electrodes, a current proportional to the concentration of the gas being measured flows between the positive and negative electrodes. Measuring this current determines the gas concentration. Because of the current generated during this process, electrochemical sensors are often called amperometric gas sensors or microfuel cells. In practice, due to the continuous electrochemical reactions occurring on the electrode surface, the sensing electrode potential does not remain constant, which can lead to sensor performance degradation after a long period of time. To improve sensor performance, reference electrodes were introduced.
The above is the working principle of the electrochemical sensor of the chlorine leak alarm. Companies can better use it by learning more about chlorine toxic gas detectors, thereby providing a safety guarantee for the company's safe production!
Precautions for installing chlorine leak alarm
The alarm probe is mainly a detection element that contacts the combustion gas sensor. It is composed of a platinum wire coil covered with alumina and adhesive to form a sphere. Its outer surface is attached with platinum, palladium and other rare materials. Metal. Therefore, care must be taken during installation to avoid breaking the probe.
The alarm should generally be installed at a height to facilitate routine maintenance by maintenance personnel.
The alarm is a safety instrument with sound and light display functions. It should be installed in a place where it is easy for staff to see and hear it, so that hidden dangers can be eliminated in time.
There should be no strong electromagnetic fields (such as high-power motors and transformers) that affect the operation of the instrument around the alarm.
The density of the gas to be measured is different, and the installation position of the indoor probe should also be different. When the density of the gas to be measured is less than the density of air, the probe should be installed away from the roof with the direction downward. On the contrary, the probe should be installed away from the ground with the direction upward.
Jinan Shuoan Electronic Technology Co., Ltd.
Contact Manager Zhang Telephone Please call for specific prices