Product Details
Anti-glare floodlights are widely used for floodlighting in various devices, platforms, corridors, passages, workshops, factories and other places.
Using high-efficiency, long-life gas discharge lamps as the light source, and through advanced light distribution design and special processing, the light is soft and uniform, without glare, and the power factor is > an average service life of more than 1 hour.
Adopting optimized structural design and high-strength aluminum alloy shell, it has the ability to resist strong vibration and impact.
Corrosion-resistant shell material and surface coating treatment ensure that the lamp will not corrode or rust in harsh environments.
The light bulb can be replaced by gently flipping the transparent part, which is very convenient.
The lamps and electrical boxes are of split design, small in size, light in weight, compact and beautiful in structure, and simple and smooth in appearance.
Various installation methods such as light poles, suspended ceilings, and booms can meet lighting needs in different environments.
Rated voltage/
Power factor greater than
Protection level
Anti-corrosion level
Insulation level
Pitch-to-height ratio
Inlet thread/,~
Overall dimensions, lamp body ballast box
Weight, lamp body ballast box
According to the site environment and lighting needs, determine the installation position and appropriate installation method of the lamp and ballast. And prepare a three-core cable of corresponding length according to the distance from the ballast to the power contact.
. Fix the lamp and ballast at the determined installation position.
Use a socket wrench to unscrew the two fastening bolts on the ballast box cover, open the ballast box cover, and introduce one end of the three-core cable of the lamp through the introduction device of the ballast output port. into the ballast cavity and connect to the corresponding specified location.
. Introduce one end of the prepared three-core cable into the ballast cavity through the introduction device at the input port of the ballast box, and connect it to the corresponding specified position in the electrical box.
, close the ballast box cover and tighten the fastening bolts, and then connect the other end of the three-core cable to the power supply to achieve lighting.
When replacing a light bulb, first cut off the power supply, loosen the locking nut on one side of the lamp head, open the lamp head through the hinge flip mechanism, unscrew the old bulb, and replace it with a new one.
When in use, there will be a certain temperature rise on the surface of the lamp. This is a normal phenomenon and the center temperature of the transparent parts is relatively high and should not be touched.
. The suitable installation height of this lamp is ~ meters, and the maximum projection range is meters.
If the external flexible cable or cord of this lamp is damaged, the cord must be replaced by the manufacturer or its service agent or a person with relevant experience.
Warning: Do not install directly on combustible materials
When installing and maintaining lamps, the power must be disconnected first
The lamps must be reliably grounded
The company has passed the international quality system audit and certification and strictly implements it The product is produced according to international quality management system standards to ensure that product quality fully meets national standards and design requirements. The product is subject to an annual warranty (one year for the light source) from the date of purchase. If the product fails during normal use, the company will be responsible for free maintenance.
Explosion-proof floodlight series Explosion-proof floodlight Explosion-proof platform light Explosion-proof induction lamp Explosion-proof floodlight Pocket explosion-proof flashlight Intelligent dimming Explosion-proof searchlight Dimming focus Explosion-proof headlight Intelligent dimming Explosion-proof inspection light Emergency floodlight Emergency Floodlight emergency access light anti-glare access light anti-glare access light stepless platform light anti-glare flood light anti-glare ceiling light high-efficiency flood light high-efficiency flood light anti-seismic flood light anti-seismic flood light high ceiling light high ceiling light series anti-glare Light anti-glare pathway light
Disclaimer
The information/pictures/parameters, etc. displayed on this webpage about【NFP060 anti-glare floodlight】are provided by member【温州日昇照明电气有限公司销售部
】,By Titker Trade Network members 【温州日昇照明电气有限公司销售部
】is solely responsible for the authenticity, accuracy and legality of the information/pictures/parameters, etc.,Titker Trade Network only provides display services. For your safety, please choose Titker Trade Network for online trading, otherwise Titker Trade Network will not bear any responsibility for this.
If your legitimate rights and interests have been infringed, please contact Titker Trade Network customer service as soon as possible. We will serve you wholeheartedly. Thank you for your attention and support to Titker Trade Network!