Hello and welcome toTitker Trade Network!
LED防爆平台灯、LED防爆泛光灯、LED防爆道路灯、LED防爆投光灯、防眩泛光灯、防眩平台灯、防眩棚顶灯、防眩通路灯、低顶灯、防震

free member

NFP290 anti-glare floodlight

价格 100.00元/套
total supply
1000 套
MOQ
1 套
brand
日昇照明
area
ZhejiangWenzhou city
Delivery period:
Shipped within 3 days from the date of payment by the buyer
Buyers are still looking
  • 1
  • 2
  • 3
Products Recommended

NPE790 explosion-pro

¥100.00/套

NFP088 anti-glare fl

¥100.00/套

SFW6110B

¥100.00/套

Shandong NFE180-NFE1

¥100.00/套

NFP070 low ceiling l

¥100.00/套

NMP970 large mobile

¥100.00/套

Shop information

area:Zhejiang Wenzhou city

Member level:corporate memberYear1

identity:  

Already paid:0.00 yuan deposit

my badge: [Integrity File]

online service:

Business card

温州日昇照明电气有限公司销售部

Applets
【Kind tips】When you call, please mention that you saw us on Titker Trade Network, thank you.
Product Details
Anti-glare floodlight
In order to meet the lighting characteristics and needs of railway tunnels, highways, electric power, metallurgy, petroleum and petrochemicals, and various factories, workshops, bridges, stations, squares, large facilities, venues, etc., the latest research and development Type anti-glare pathway light, no glare, no ghosting, shockproof and corrosion-resistant, energy-saving, safe and reliable.
The anti-glare function uses nano-photocatalyst glass, which can automatically decompose surface stains and maintain light transmission. At the same time, diffuse reflection technology and protective angle design are used to effectively prevent glare, effectively reduce irritation to the eyes of workers and construction workers, and avoid discomfort and discomfort. Feeling of fatigue.
Light efficiency and energy saving use a special gas discharge bulb as the light source, which has high light efficiency and long life. When using a double-tube lamp, it can be started and restarted immediately without cooling.
Applicable environment: High-strength alloy materials are used, which have strong resistance to strong collision and impact. Multi-channel shock-proof structure and surface spraying treatment can be used for long-term stability in high-frequency vibration, humid, and high-temperature environments such as workshops, roadbeds, and rails. Work.
Installation methods include wall-mounted and ceiling-mounted installation methods. The illumination angle can be adjusted arbitrarily in the upper and lower ranges according to needs. Cables of different diameters can be adapted according to the needs of the site, and multiple lights can be connected in parallel, which is suitable for Layout engineering lighting. Electronic and mechanical dual protection devices automatically cut off the power supply after opening the cover, making use and maintenance safer and more reliable.
Rated voltage/
Power factor greater than
Protection level
Anti-corrosion level
Insulation level
Pitch-to-height ratio
Inlet thread/,~
Overall dimensions**
Weight
Equipped with light source
Order number Equipped with light source, rated power, luminous flux, average service life
According to the site environment and lighting needs, determine the lighting fixtures After installing the position and method, fix it and prepare the corresponding length of cable according to the distance from the lamp installation position to the power contact.
Unscrew the two butterfly bolts fixing the front cover on the upper part of the lamp, open the front cover, and introduce one end of the prepared cable into the lamp cavity through the compression nut of the introduction device. According to the polarity marked on the terminal block, Connect the wiring and tighten the compression nut of the introduction device.
, close the front cover, tighten the two butterfly bolts on it, and then connect the other end of the cable to the power supply to illuminate.
When multiple lamps are used in parallel, lead in the cable from another lead-in device and wire it according to the above method. When connecting to other lamps for single lamp use, plug the idle lead-in device with a plug.
Loosen the fixing screws on both sides of the bracket to adjust the lighting angle of the lamp in the upper and lower range.
There is a support rod inside the lamp cavity, which can be supported as needed after opening the lamp cover.
When transporting, put the lamps in the provided cartons and add foam for shock absorption.
When in use, there will be a certain temperature rise on the surface of the lamp. This is a normal phenomenon and the center temperature of the transparent part is relatively high. Do not touch it directly with your hands.
When replacing a light bulb, try to use the same type of light bulb. If the type or power of the light bulb is changed, the supporting ballast should be replaced accordingly.
The temperature resistance of the cables introduced into the lamp cavity should not be lower than ℃ (such as silicone rubber, polytetrafluoroethylene cables, etc.).
Warning can be installed directly on combustible materials
When installing and maintaining lamps, the power supply must be disconnected first
The lamp must be reliably grounded.
The company has passed the international quality system audit and certification. This product is produced in strict compliance with international quality management system standards to ensure that product quality fully meets national standards and design requirements. The product is subject to an annual warranty (light source is guaranteed for one year) from the date of purchase. Within one year, if any malfunction occurs during normal use of the product, our company will be responsible for free maintenance.
Explosion-proof floodlight series Explosion-proof floodlight Explosion-proof platform light Explosion-proof induction lamp Explosion-proof floodlight Pocket explosion-proof flashlight Intelligent dimming Explosion-proof searchlight Dimming focus Explosion-proof headlight Intelligent dimming Explosion-proof inspection light Emergency floodlight emergency Floodlight emergency access light anti-glare access light anti-glare access light stepless platform light anti-glare flood light anti-glare ceiling light high-efficiency flood light high-efficiency flood light anti-seismic flood light anti-seismic flood light high ceiling light high ceiling light series anti-glare Light anti-glare pathway light
Disclaimer

The information/pictures/parameters, etc. displayed on this webpage about【NFP290 anti-glare floodlight】are provided by member【温州日昇照明电气有限公司销售部 】,By Titker Trade Network members 【温州日昇照明电气有限公司销售部 】is solely responsible for the authenticity, accuracy and legality of the information/pictures/parameters, etc.,Titker Trade Network only provides display services. For your safety, please choose Titker Trade Network for online trading, otherwise Titker Trade Network will not bear any responsibility for this.

If your legitimate rights and interests have been infringed, please contact Titker Trade Network customer service as soon as possible. We will serve you wholeheartedly. Thank you for your attention and support to Titker Trade Network!

Titker Trade Network