Product Features
The ventilation multi-parameter detector (mine ventilation resistance measurement system) is a device that can measure simultaneously Precision handheld portable instruments for atmospheric pressure, differential pressure, wind speed, temperature, and humidity measurement of ventilation resistance.
(
Original imported from the United States
)
The explosion-proof type of this instrument is intrinsically safe, and its explosion-proof mark is.
Implement standard number/"Ventilation Multi-Parameter Detector".
Main uses and scope of use
Main uses
Mainly used to measure atmospheric pressure, differential pressure, wind speed, temperature, humidity, and for ventilation resistance measurement.
Scope of application
Fire protection, limited space detection, municipal administration, chemical industry, gas.
Product name and model
Product name Ventilation multi-parameter detector
Product model.
The composition of the number and its representative meaning
The measuring instrument is named according to the following method
Product type code testing instrument
First characteristic code ventilation
Classification instrument
Version
Environmental conditions
) Temperature (~)℃
) Relative humidity, ℃
) Atmospheric pressure (~)
Full features
) Explosion-proof type Intrinsically safe.
) Explosion-proof mark I.
Technical characteristics
Key functions
Measure underground atmospheric pressure, wind speed, temperature, humidity, differential pressure (standard)
Carbon monoxide (optional), carbon dioxide sensor (optional)< br/> Technical indicators
) Sensor types that can be coupled: atmospheric pressure, wind speed, temperature, humidity, differential pressure carbon monoxide (optional), carbon dioxide sensor (optional)
) Measuring range
Atmospheric pressure Strength
Differential pressure
Wind speed accuracy/accuracy/
Temperature ℃~℃ accuracy
Humidity~accuracy
) Data recording group, can be recorded automatically or manually
) Data download and processing interface, equipped with ventilation resistance test software
) Shell protection level
) Display mode LCD display
) Battery model and capacity Nanfu durable AA-size nickel-metal hydride rechargeable battery ,/section
) Working voltage and working current.
) Working hours
) Explosion-proof type is intrinsically safe, and the explosion-proof mark is open circuit voltage and short circuit current
) Dimensions
) Weight
>
Multiple parameters of mine ventilation Detector
>Working Principle
The instrument is composed of a low-power single-chip microprocessor and peripheral interface circuits. The peripheral interface circuit is composed of, frequency/digital conversion circuit, analog/digital conversion circuit, serial communication circuit, clock circuit and. The frequency signal and temperature compensation voltage signal of the pressure sensor are sent to the calculated pressure value after /conversion and /conversion respectively, and then the pressure value is sent to the display for display. Similarly, the wind speed and humidity sensor signals are also sent to the calculation after / and /conversion. Wind speed and humidity values. The output of the temperature sensor is a digital signal, so it does not need to be converted and is directly sent to calculate the temperature value.
Mine Ventilation Multi-Parameter Detector
>Measurement Operation
Display Settings
Through the display setting menu, you can set the parameters that need to be displayed on the display. You can choose to display the parameter on the screen by selecting the highlighted parameter on the menu, or turn off the display of the parameter by selecting, and select the main parameter to display the parameter in a large font on the screen. Only one parameter can be selected to be displayed as the main parameter. In addition, up to three parameters can be selected and displayed on the screen as secondary parameters.
Pressure Clear
Select the (Pressure Clear) menu to clear the pressure reading. The host will display whether the reset is successful.
Settings
Through the settings menu, you can complete basic settings including parameter units, system time, system date, time format, turning off the backlight, and automatic shutdown. Use the or keys to adjust each option setting and then press the OK key to confirm the setting.
Actual/Standard Settings
In the menu item Select/Options, the user can select the standard temperature, standard pressure and actual temperature source. The ventilation multi-parameter detector measures the actual atmospheric pressure.
Mine ventilation multi-parameter detector
>Maintenance
No special maintenance is required to maintain good condition
The calibration menu can be used for calibration during on-site testing, for the purpose of on-site debugging It uses minimal adjustments to meet user calibration standards. On-site adjustment is not a complete calibration. In order to achieve completeness, multi-point calibration and verification are required, and the calibration is sent to the manufacturer or a nationally authorized measurement institution for annual recalibration.
Mine ventilation multi-parameter detector
>Common faults and solutions Problems and possible causes of faults and solutions
The screen does not show that the power is not turned on
The battery is low or exhausted Replace the battery or use an AC adapter
Poor contact in the battery compartment circuit. Clean the battery compartment circuit
The wind speed reading is unstable and the flow field is unstable. Reposition the probe to a place where the flow field is stable or use a large time constant
The keyboard is unresponsive. The keyboard is locked and press ▲▼ at the same time to unlock the keyboard
An instrument error message appears. There is no memory space to download the required data and then deletes all data.
A probe error message appears. The probe is faulty. The probe needs to be returned to the factory for repair
/> >
Mine ventilation multi-parameter detector
>Precautions
) During maintenance, the electrical parameters, specifications and models of intrinsically safe circuits and components and devices related to intrinsically safe circuits must not be changed .
) It is strictly prohibited to replace or disassemble batteries in non-safe places.
) Charging must be done in a safe place, and it is strictly prohibited to use batteries other than those specified in the instructions.
) must wear an animal leather cover when using it.
)Prevent the machine from falling from a high place or being subject to severe vibration
)The machine may not be able to be used normally when high concentrations of gas are present
)Please operate and use it strictly in accordance with the instructions, otherwise it may cause The measurement results are inaccurate or the machine is damaged
) This product must not be stored or used in an environment containing corrosive gases (such as chlorine, etc.), nor in other harsh environments (including excessively high or low temperatures, relatively high temperatures, etc.) Use and store the machine under high humidity, electromagnetic fields and strong sunlight
) If there is dirt on the surface of the machine after long-term use, please wipe it gently with a clean soft cloth instead of using corrosive materials. Use solvents and hard objects to wipe the surface of the machine, otherwise the surface of the machine may be scratched or damaged.
) In order to ensure measurement accuracy, this machine should be calibrated regularly, and the calibration cycle should not exceed one year.
) Please remove the used battery of the measuring instrument and send it to the designated place or return it to our company. Do not throw it into the trash can.
Please contact the manufacturer for any application or usage problems beyond what is described in this manual.
Mine ventilation multi-parameter detector
> Transportation and storage
During transportation, exposure to the rainforest should be avoided, violent collisions should be prevented, and throwing and heavy pressure are strictly prohibited.
) The measuring device should be stored in an environment with dry air and no corrosive gases.
) The measuring instrument should be kept by a dedicated person and inspected and maintained regularly.
Mine ventilation multi-parameter detector
> Unpacking and inspection
Immediately after unpacking, check whether the detector is intact and the quantity is accurate. Whether the attachments, certificates of conformity, instructions, coal safety, explosion-proof certificates and other information are complete. Otherwise, please contact the manufacturer in time.
Mine ventilation multi-parameter detector
> Random information and accessories
Suitcase
Machine
Head
Nanfu durable AA rechargeable battery
Instructions for use
Factory certificate
Product certificate
Mining product safety mark certificate
Inspection certificate
Explosion-proof certificate
National sales hotline< br/>Business
Office phone number
Contact person Yu Guiyong
Product list of Beijing Okostar Technology Development Co., Ltd.
Multi-parameter gas detector (four-in-one)
Multiple gas detection alarms (four-in-one)
/Methane carbon monoxide detector (two-in-one) /
Methane oxygen detector (two-in-one)
/
Methane Carbon dioxide detection alarm
Infrared carbon dioxide detector
Hydrogen sulfide detector
Oxygen meter
Oxygen detector
Methane detector
Carbon monoxide detector
Infrared carbon dioxide detection alarm
Infrared methane detection alarm
Multi-parameter gas meter
Multi-parameter gas meter
Multi-parameter meter (portable multi-function gas detection alarm Instrument)
/Type optical interference gas detector
Suspended multi-parameter gas detector
/Suspended methane carbon monoxide detector
/Suspended methane oxygen detection alarm
/>Sulfur dioxide detection alarm
/
Nitrogen dioxide nitric oxide detector
Hydrogen detection alarm for mining
Carbon monoxide detector
/
Carbon monoxide Hydrogen sulfide gas detector
/
Oxygen carbon monoxide detector
Type coal seam gas outburst prediction instrument
Mine ventilation multi-parameter detector
+ Mine ventilation resistance measurement system ( Ventilation multi-parameter detector
Ventilation multi-parameter detector
+Portable multi-parameter tester is also called ventilation resistance tester
+ Type series mechanical and electronic anemometer for coal mines
Type type Inclined differential pressure gauge
+ type three-speed electronic anemometer for mining
Mechanical ventilation psychrometer
Empty box barometer+
Type compensated micro pressure gauge
Series Pitot tube
Mechanical anemometer for coal mines
.
Disclaimer
The information/pictures/parameters, etc. displayed on this webpage about【JFY-4 mine ventilation multi-parameter detector】are provided by member【Beijing Goodcoastal Technology Development Co., Ltd
】,By Titker Trade Network members 【Beijing Goodcoastal Technology Development Co., Ltd
】is solely responsible for the authenticity, accuracy and legality of the information/pictures/parameters, etc.,Titker Trade Network only provides display services. For your safety, please choose Titker Trade Network for online trading, otherwise Titker Trade Network will not bear any responsibility for this.
If your legitimate rights and interests have been infringed, please contact Titker Trade Network customer service as soon as possible. We will serve you wholeheartedly. Thank you for your attention and support to Titker Trade Network!