Product Details
Round copper rod indoor and outdoor high-voltage wall bushings / Round copper rod indoor and outdoor high-voltage wall bushings
1. Overview
High-voltage wall bushings (hereinafter referred to as bushings) are suitable for rated voltages (~ On the three-phase AC system power station and substation distribution device with frequency (~), the conductive part passes through the partition, wall or other grounding object, and serves as the insulation support and fixed connection between the external conductors (busbar).
Using environmental conditions
) Indoor casing
Ambient temperature shall not be higher than +℃ and not lower than ℃
Altitude shall not exceed
The monthly average relative humidity shall not be greater than
The surrounding air should be free from corrosive or flammable gases, water vapor and other obvious contamination
No frequent violent vibrations
) Outdoor casing
The ambient temperature should not be higher than +℃, not low At ℃
The altitude does not exceed
The wind speed does not exceed/
The degree of air pollution in the environment where the product is used is divided into Ⅰ, Ⅱ, Ⅲ and Ⅳ levels
No frequent Violent Vibration
2. Product Features
The bushing is composed of porcelain parts, metal accessories, mounting flange and conductive bar (rod).
3. Use and Classification
Wall-through porcelain bushings are used in power station and substation power distribution devices and high-voltage electrical appliances. They are used for wires to pass through grounding partitions, walls or electrical equipment shells, and to support conductive parts so that they can Insulated from ground or enclosure.
Wall-penetrating porcelain casings can be divided into indoor and outdoor wall-penetrating porcelain casings according to their usage environment. According to the different conductors passing through its center, it can be divided into busbar wall-penetrating porcelain bushings, copper conductor wall-penetrating porcelain bushings and aluminum conductor wall-penetrating porcelain bushings.
When the copper conductor is directly connected to the busbar, galvanic corrosion is prone to occur, and the temperature of the contact surface rises too high, causing the joint to burn out and affecting the life of the equipment. Therefore, a copper-aluminum transition joint should be used, but it also brings trouble to on-site construction. The above problems can be solved by using aluminum conductor porcelain bushings.
Indoor and outdoor wall-penetrating porcelain bushings are assembled from porcelain parts, conductive rods, metal accessories at both ends and mounting flanges. The busbar wall-penetrating porcelain bushing is assembled from porcelain parts, metal accessories at both ends, busbar plywood and mounting flange (the busbar plywood is usually configured by the user according to the busbar size).
The various properties of wall-penetrating porcelain bushings comply with the requirements of the Technical Conditions for High-voltage Wall Porcelain Bushings.
4. Model Description
\\~\\\\\\
5. Installation and Use Instructions
Wall porcelain bushings are suitable for the environment around the installation site under power frequency AC rated power. Power stations and substation power distribution devices with temperatures ranging from ℃ to +℃ and altitudes not exceeding.
Internal wall bushings are not suitable for use in places where the enamel, metal accessories and cement adhesives of the bushings are damaged or are sufficient to reduce the electrical performance of the bushings.
If partial discharge occurs during the operation of the wall porcelain casing, check whether there is any partial peeling off of the aluminum spray layer at the flange or inner cavity of the porcelain casing. If so, temporary pressure equalization measures should be taken promptly.
The wall hole for installing the busbar wall-penetrating porcelain bushing should be opened according to the maximum size of the flange reinforcement.
6. Appearance and installation dimensions
\\~\\\\\
Model
Rated voltage
Rated current
Second short-time current is not less than
Outdoor end nominal creepage distance
Power frequency voltage is not less than
Not less than< br/>
Bending failure load is not less than
Dry resistance
Wet resistance
Breakdown
Visible corona
< br/>
< br/>
< br/>
< br/>
< br/>
< br/>
*
*
< br/>
*
*
< br/>
*
Disclaimer
The information/pictures/parameters, etc. displayed on this webpage about【CWB-35KV/(400-2000)A round copper rod high voltage wall bushing】are provided by member【上海永册电器有限公司
】,By Titker Trade Network members 【上海永册电器有限公司
】is solely responsible for the authenticity, accuracy and legality of the information/pictures/parameters, etc.,Titker Trade Network only provides display services. For your safety, please choose Titker Trade Network for online trading, otherwise Titker Trade Network will not bear any responsibility for this.
If your legitimate rights and interests have been infringed, please contact Titker Trade Network customer service as soon as possible. We will serve you wholeheartedly. Thank you for your attention and support to Titker Trade Network!