Hello and welcome toTitker Trade Network!
Volkswagen Appliances Technical Aftermarket Service Center

free member

Ningbo Midea Air Conditioning After-Sales Service Center Telephone Number-Welcome-

total supply
0
MOQ
0
brand
美的
area
ZhejiangNingbo City
Delivery period:
Shipped within 3 days from the date of payment by the buyer
Buyers are still looking
  • 1
  • 2
  • 3
Products Recommended

Fenghua Soy air cond

Negotiable

Ningbo Gree Air Cond

Negotiable

Fenghua Gree air con

Negotiable

Fenghua Midea air co

Negotiable

Fenghua Haier air co

Negotiable

Fenghua Gree Air Con

Negotiable

Shop information

area:Zhejiang Ningbo City

Member level:corporate memberYear1

identity:  

Already paid:0.00 yuan deposit

my badge: [Integrity File]

online service:

Business card

Volkswagen Electric Technical Service Center

  • name:客服(sir) 
  • phone:0574-88260962
  • mobile phone:15381952132
  • address:段塘西路72号
Applets
【Kind tips】When you call, please mention that you saw us on Titker Trade Network, thank you.
Product Details
Welcome to Ningbo Midea Air Conditioner After-sales Service Center
〓〓Ningbo City: (Manufacturer) Unified Maintenance Customer Service Center Service Station specializes in repairing air conditioners that do not heat, do not cool,
do not start, leak, and cannot operate the remote control Function, fan not working, tripping, Freon leakage, fault code, and other faults, repair, cleaning, maintenance services
[Midea] [Factory] [Home] [Defined] [Defined] [Maintenance] [Repair] [Chinese] 】【心】
Ningbo Midea air conditioner repair service hotline: 〓〓, call for repair within hours, I believe your choice is right. A good life starts from
Midea air conditioner Ningbo Midea After-sales Service Center was established in 2008. Since its establishment, Focusing closely on professional service standards,
promote the development and growth of enterprises with my dedicated, you can rest assured service spirit, win the market and repay the society with honest and pragmatic service concepts, so that enterprises can compete extremely
fiercely It has developed steadily in the home appliance market for many years and achieved good economic and social benefits.
Ningbo Midea air conditioner after-sales maintenance service commitment:
Strictly maintain Midea in accordance with maintenance procedures and operating regulations to ensure maintenance quality.
Strictly control the quality of accessories and eliminate the use of fake and inferior accessories and waste accessories.
The service hotline is manned every hour and will respond within hours. The maintenance workshop and the front desk will not be closed during holidays to ensure that users can be repaired at any time. A maintenance system has been established in a timely manner
An emergency repair team has been established to arrive at the site for emergency repairs at any time.
In terms of charging, we strictly implement the charging standards of the Municipal Price Bureau and our company, do not exaggerate faults, and put an end to arbitrary charges.
, remote fault diagnosis, technical troubleshooting for out-of-town customers, and quick processing of postal accessories if needed. If out-of-town customers send it in for repair themselves, we will expedite troubleshooting
for your machine and strive to complete the repair on the same day.
All machines repaired by our center in Ningbo for original air conditioning repairs will be subject to warranty. If there is a problem due to the quality of repairs or replacement parts during the warranty period, our center will be responsible for return repairs.
Midea’s service goal: defects, % customer satisfaction. The city listens to customers’ voices carefully
Hourly after-sales service call and repair call〓〓
Company purpose: rich experience, quality assurance, safety first, customers, comfort, Peace of mind and peace of mind
The corporate goals of Ningbo Midea Air Conditioning:
Strive to build the Midea air conditioning service brand and strengthen employees' brand service awareness.
Everything depends on people: Midea’s problems have changed a lot. I believe there is no problem that cannot be solved. The employees of Ningbo Midea Air Conditioning Center must not only be able to solve unknown problems but also solve them in a timely manner
Never encountered problems. Attitude determines everything. Communication solves everything no matter what. Can the problem be solved in time?
Arriving at the customer's home or company in a timely manner is the top priority. We will use an interactive approach to provide customers with the greatest help and support. Employees must carry essential tools
with them!
After-sales hotline: 〓〓Midea Corporate Culture◇◇◇Corporate Vision Corporate Social Responsibility constitutes the essence of Midea’s corporate culture
The corporate goal is to lead the country and catch up with the world.
There is no excellence in the concept of struggle, only transcendence. Become a globally respected company. Corporate mission creates social value. Corporate SpiritResponsibility, Innovation,
Tenacity. Core Values Employee Satisfaction Customer Satisfaction Shareholder Satisfaction.
Our purpose: sincerity, innovative service
Our goal: professionalism, concentration, industry leadership
Our spirit: unity and liveliness, hard work
Our culture: pragmatism and innovation , strive for self-improvement
Our style: do not ask for anything in return, serve with a smile
Ningbo Midea after-sales phone number (manufacturer) unified maintenance customer service center phone number: 〓〓
Service scope: Ningbo original urban area.
*Midea’s smart defrost technology solves many world-class problems, greatly improves the comfort of air conditioners, and improves the heating effect by % compared with traditional air conditioners.
Ningbo Midea after-sales maintenance 24-hour service Hotline service details:
Midea's commitment: 24/7 service.
.Five free, five satisfactory services:
Five satisfactions: satisfactory service, satisfactory design, satisfactory installation, satisfactory use, and satisfactory maintenance.
Ningbo Midea After-Sales Repair Service Center is at your service! ! ! ! ! ! ! ! ! ! ! ! !
Original after-sales phone number of Midea air conditioner in Ningbo 〓〓 Midea manufacturer maintenance original office in Ningbo repair acceptance hotline
〓〓 Service procedures: Telephone repair, door-to-door inspection, accurate quotation, repair, recovery and warranty.
Safety, standardized maintenance, and regular maintenance. The accessories are authentic and come with a warranty.
Service goal: % customer satisfaction for service defects, as long as you call the company's hourly repair hotline
The company will serve you wholeheartedly as soon as possible
Ningbo Midea air-conditioning after-sales service outlet repair hotline: Midea's dedicated line will serve you at home. Midea air-conditioning repair in the original city of Ningbo warms the hearts of thousands of families. Midea air-conditioning repair guarantees your satisfaction. Midea air-conditioning repair in the original city of Ningbo. Original parts air-conditioning repair. Serving the people with honesty and trustworthiness. On-call service and considerate quality are the best! Ningbo Midea air conditioner after-sales maintenance telephone hourly repair hotline:
〓〓Midea brand (original in Ningbo) professional repair site repair hotline (full door-to-door service to provide you with the best service! Midea air conditioner professional maintenance)
Full health hang-up : Display content fault type
Fault: The indoor temperature is very cold after turning on the machine and it still does not shut down
: It may be that the temperature control has failed. Solution: Replace.
Whether the user turns the temperature control switch to the lowest point on the far right.
Fault: The air volume at the air outlet is very small and the temperature cannot drop.
: The filter may be blocked by dust.
The fan motor rotates slowly. Replace the motor or capacitor.
:The fan blade fixing screw is loose.
Fault: Some capillary tubes are soft and vibrate during operation, causing noise
The capillary tube hits the axial flow fan blade. Carefully check whether it is stuck or biased. If it is intact, readjust and tie it up
Failure: Loud noise, large vibration
: Improper installation, the fixing screw feet of the mounting bracket are not padded or tightened.
Due to the deflection of the long-distance transmission mounting bolt feet, the compressor is uneven and squeezed, causing vibration and noise.
:The axial flow fan blades touch the guide ring.
: The capillary collides with the fan blades.
: The pipes collide or vibrate with the shell, and the bandaging needs to be readjusted.
Fault: No water flows out of the air conditioner
: The voltage is low and the air conditioner keeps turning on and off. If it is turned on for a short time and stopped for a long time, the condensed water in the chassis will be blown to the condenser by the axial flow blades. evaporate
.
The room is closed for a long time when the machine is turned on, causing indoor dryness, or the weather itself is dry.
Fault: Cannot operate after power on
: The contacts of the main command switch and selector switch are damaged and loose.
The wiring is wrong and the wire plug is detached.
: Temperature control failure, quality problem, replace the temperature control.
Fault: Air conditioner leakage
: The user socket is not grounded, which is an induced voltage.
The live and neutral wires are mixed.
: The control board is wet, and the resistance of the insulated meter to the ground is less than.
: The temperature control panel of the window machine is squeezed, and the protective cover ages and deteriorates, causing leakage.
: Check whether the motor or compressor is leaking electricity.
: The live wire skin is cracked or peeled off, causing leakage.
Fault: The light on the window machine light panel does not light up or the lights light up at the same time
: The fuse is blown.
The resistor and light-emitting diode are burned out
Complete analysis of Midea cabinet machine faults:
Fault: No response after power on, the light does not flash and the buzzer does not sound.
: Check the indoor unit wiring board to see if there is working voltage between the positions.
: Check whether the fuse is blown.
: Check whether the transformer has normal output of yellow group and white group.
: Check whether there is + output, if it is too low, check whether there is leakage.
Fault: The running indicator light flashes when the machine is turned on, and then displays when the machine is stopped.
: Displayed immediately upon booting up.
: Check whether the bits in the six-core wire are connected. If there is no connection, it is an outdoor fault. You should check whether the connection of the six-core wire is reliable and whether the high-voltage protector, overcurrent protector
and overheating protector are connected.
For example, bit path, it is a fault in the indoor control part.
: Displayed after running for a period of time.
: Check the operating current. If the current reaches or when the protection starts, the overcurrent protector is working.
Check the high voltage of the system. If the protection is activated when it reaches the above level, it is a pressure protection function
Specific inspections:
Whether the power supply is normal, whether there is a phase loss, whether the live wire and the neutral wire are mixed current protection.
Is the outdoor condenser clean?
Check whether the outdoor fan is running normally and whether the fan blades are broken.
Whether the pipeline is blocked and whether there is too much fluorine.
Whether the valve is fully open.
Whether the installation location is appropriate.
Fault: After starting up, the room temperature shows zero degrees and the cooling operation cannot be performed.
: Check whether the indoor temperature sensing head is broken.
: Is the temperature sensing plug plugged in properly?
: Check whether the resistance value between the temperature sensing plug and the pin end of the display board is. If it is lower than this value, the display board is leaking, just remove it.
Fault: Displayed after power on or after working for a period of time.
Cause: Evaporator frost protection.
: Check whether the indoor pipe temperature head is broken.
: Is the indoor temperature sensing plug plugged in properly?
: Check whether the resistance value between the temperature sensing plug of the display board and the pins is . If it is lower than this value, it means the display board is leaking electricity. Just remove it.
Fault: The indoor temperature is displayed when the machine is turned on, and the cooling system does not stop.
Cause: The indoor temperature sensing head is short-circuited.
Check:
: Whether there is water accumulation in the temperature sensing plug, causing a water short circuit.
: Is the resistance of the indoor temperature sensor head normal?
Fault: The indoor and outdoor fans run when the machine is turned on, the temperature is normal, and the compressor does not start.
Check:
: Whether the six-core wire has normal working voltage.
: Whether the AC contactor is burned out.
: Whether the compressor capacitor and compressor are normal.
: If the voltage is normal when the power is turned off, but drops to less than 100 volts after the power is turned off, the neutral line and the three live wires of the power supply do not come from the same transformer.
Dear user, no matter what your needs are, as long as you call our hourly unified service hotline: we will do the rest}
Our customer service representatives will provide you with professional Consultation and answers!
, We will arrange excellent service engineers from the nearest maintenance outlets to come to your door on time at the time you agreed!
While providing high-quality services, engineers will explain the working principle and operation process of the product to you in detail!
At the end of the service, the engineer will take the initiative to explain the common sense of product use to you and guide your use
Disclaimer

The information/pictures/parameters, etc. displayed on this webpage about【Ningbo Midea Air Conditioning After-Sales Service Center Telephone Number-Welcome-】are provided by member【Volkswagen Electric Technical Service Center 】,By Titker Trade Network members 【Volkswagen Electric Technical Service Center 】is solely responsible for the authenticity, accuracy and legality of the information/pictures/parameters, etc.,Titker Trade Network only provides display services. For your safety, please choose Titker Trade Network for online trading, otherwise Titker Trade Network will not bear any responsibility for this.

If your legitimate rights and interests have been infringed, please contact Titker Trade Network customer service as soon as possible. We will serve you wholeheartedly. Thank you for your attention and support to Titker Trade Network!

Titker Trade Network