The official telephone number of Nanning Haier central air-conditioning after-sales maintenance department "Outdoor unit does not turn"

价格 30.00元/台
total supply
100000000 台
MOQ
1 台
area
GuangxiNanNing City
Delivery period:
Shipped within 3 days from the date of payment by the buyer
Buyers are still looking
  • 1
  • 2
  • 3
Products Recommended

2015 Nanning Haier w

¥30.00/台

Midea) Nanning Midea

¥30.00/台

Nanning Midea washin

¥30.00/台

Nanning Tsinghua Uni

¥30.00/台

Nanning Gree Air Ene

¥30.00/台

Nanning Haier air so

¥30.00/台

Shop information

area:Guangxi NanNing City

Member level:corporate memberYear1

identity:  

Already paid:0.00 yuan deposit

my badge: [Integrity File]

online service:

Business card

Yishi Home Appliances Maintenance Department, Nanning

Applets
【Kind tips】When you call, please mention that you saw us on Titker Trade Network, thank you.
Product Details
Haier central air conditioning Nanning after-sales hotline or (Haier manufacturer maintenance) Nanning office repair acceptance hotline or service procedures: call for repair, door-to-door inspection, accurate quotation, repair, recovery and warranty. Safety certification, standardized repairs, and formal maintenance. The accessories are authentic and come with a warranty.
Service goal: % customer satisfaction for service defects,
As long as you call the company’s hourly repair hotline or our company will serve you wholeheartedly as soon as possible!
Nanning Haier central air-conditioning after-sales service outlet repair Hotline: Haier's dedicated line will serve you at home. Haier central air-conditioning repair in Nanning warms the hearts of thousands of families. Haier central air-conditioning repair guarantees your satisfaction. Haier central air-conditioning repair in Nanning. Central air-conditioning repair with original parts. We serve the people with honesty and trustworthiness. On-site service and considerate quality are the best! Nanning Haier central air-conditioning after-sales maintenance telephone hourly repair hotline: Or the Haier brand (Nanning) professional repair station repair hotline (the whole process will provide you with the best service! Haier central air-conditioning professional maintenance)
"Haier" "Factory" " Home" "Point" "Ding" "Weight" "Repair" "Middle" "Heart"
Service scope: All urban areas in Nanning
Nanning Haier central air conditioning maintenance service hotline: or or
or or Nanning Haier after-sales (manufacturer) unified maintenance customer service center phone number, Haier electrical appliances intelligent defrost technology solves many world-class problems, greatly improves the comfort of central air conditioners, and improves the heating effect by % compared with traditional central air conditioners.
Any of the following situations does not fall within the scope of guaranteed repairs, and special service outlets can perform repairs for a fee in accordance with the relevant provisions of this manual:
Damage caused by consumers due to improper use, maintenance, and storage
Not designated by Haier Electric Appliances Damage caused by installation and repair at service outlets (including installation or disassembly and repair by consumers themselves)
No warranty certificate and valid receipt or valid purchase voucher
Valid certificate and warranty certificate are inconsistent or altered
Processed products that have been damaged due to force majeure natural disasters or harsh usage environments, and products that have exceeded the warranty period.
Nanning Haier central air-conditioning after-sales maintenance service commitment:
() Yan Haier performs maintenance in accordance with maintenance procedures and operating regulations to ensure maintenance quality.
() Strictly control the quality of accessories and eliminate the use of fake and inferior accessories and waste accessories.
() The service hotline is manned every hour and will respond within hours. The maintenance workshop and front desk will not be closed during holidays to ensure that users can be repaired at any time. A maintenance system has been established to set up a repair team in time and can arrive at the site for repairs at any time.
() In terms of charging, we strictly abide by the charging standards of the Municipal Price Bureau and our company, do not exaggerate faults, and prevent arbitrary charges.
Haier’s service goal: Defects, % customer satisfaction (citywide) and listen carefully to customers’ voices
Haier central air conditioning repair case Three-phase electric cabinet type central air conditioner outdoor unit does not work maintenance method
.Fault Phenomenon
The outdoor unit does not work.
.Fault Analysis
Most of them are caused by abnormal three-phase power supply, such as phase loss or wrong phase sequence, and a few are caused by AC contactor not working.
.Inspection
The first step is to confirm that the three-phase power input to the outdoor unit terminals is normal, adjust (exchange) any two power supply terminals and then test the machine. If the central air conditioner returns to normal operation, it means that the Wrong sequence. Because the power supply has a phase sequence, the compressor of some models can only work normally if the phase sequence is correct.
The second step is to check the AC contactor. Watch to see if the bottom coil is charred. After pressing the forced switch, the measured resistance between the corresponding output terminals is infinite, indicating that the contactor is damaged.
The third step is to measure whether there is AC in the outdoor unit signal line for the compressor control. If not, check the compressor drive circuit in the outdoor unit control board.
The fourth step is to measure the resistance between the three terminals of the compressor. Normally, the resistance between the three terminals (several ohms) is equal. If the resistance between two terminals is abnormal, or the resistance between the three terminals is If the values are not equal, it may be that the compressor is damaged.
The fifth step is to check the indoor unit pipe temperature sensor. The resistance value should be roughly the same as the room temperature sensor at the same ambient temperature.
Haier central air conditioning hourly after-sales service phone number: or or
Full health hang-up: display content fault type
Error in reading R parameter when powering on
Zero-crossing detection error
Fan speed is out of control
Four times current protection
Indoor room temperature sensor is open circuit or short circuit
Indoor evaporator temperature sensor is open circuit or short circuit
Nanning Haier central air conditioning maintenance service hotline: or or
Disclaimer

The information/pictures/parameters, etc. displayed on this webpage about【The official telephone number of Nanning Haier central air-conditioning after-sales maintenance department "Outdoor unit does not turn"】are provided by member【Yishi Home Appliances Maintenance Department, Nanning 】,By Titker Trade Network members 【Yishi Home Appliances Maintenance Department, Nanning 】is solely responsible for the authenticity, accuracy and legality of the information/pictures/parameters, etc.,Titker Trade Network only provides display services. For your safety, please choose Titker Trade Network for online trading, otherwise Titker Trade Network will not bear any responsibility for this.