The central oxygen supply station is composed of a gas cylinder group bus automatic switching console (also manual) and an alarm device. When a gas cylinder group is used as the oxygen supply source, the gas cylinders are divided into two groups, one for working and one for backup. When the oxygen pressure in a group of bottles drops to a certain specified value, the console will automatically switch to automatically switch to the backup cylinder group, that is, continuous At the same time as oxygen is supplied, the alarm device automatically emits an audible and visual alarm signal to warn the staff to replace the gas cylinder. When the output pressure is lower than the specified value, the alarm device also emits an audible and visual alarm signal to warn and take measures. When liquid oxygen and oxygen cylinders are used together, liquid oxygen can be used as the main cylinder as an auxiliary or as a backup. When an oxygen generator is installed, use a self-made oxygen source as the main cylinder as a backup.
Oxygen pipeline and stabilizing device
Oxygen is decompressed at the central oxygen supply station and then transported to the pipeline to reduce the pressure to ~ (adjustable). Oxygen is transported to each floor to meet the needs of patients’ breathing and activation. Various types of ventilators and anesthesia machines can also supply oxygen to the hyperbaric oxygen chamber.
Oxygen Terminal
The decompressed oxygen is transported by pipelines to the oxygen terminal at the bedside of each ward. The outlet of the terminal is equipped with a plug-in self-sealing quick connector and a quick connector to connect to the filtration bottle. Just insert the filter bottle into the terminal jack and the oxygen bottle will be continuously supplied to the patient. When not in use, just pull out the air source and the oxygen supply will be automatically cut off.
The number of jacks on the box terminal is configured according to the needs of the ward. Indoor pipes can be equipped with multi-shaped aluminum alloy decorative covers. It is suitable for hospitals that require surface installation, especially for hospitals that have already opened clinics. The addition of an oxygen supply system will not affect the normal operations of the hospital.
Concealed terminals are suitable for hospitals that require concealed installation. The number of jacks is configured as needed. The pipes are installed in the trough and covered with aluminum alloy decorative plates.
Combined terminals are complete in tube and belt type assembly terminals. They are made of aluminum alloy profiles or steel plates and are electrosprayed. They can be equipped with a variety of air source sockets, colors and decorations as needed, and can be equipped with paging power supply, lamps and other accessories. They are beautiful, generous and practical.
The mobile terminal is suitable for operating rooms. The hose is configured to move left and right.
The pressure regulating air distribution machine is suitable for operating rooms. Available for inhalation and activation of medical equipment with different pressure requirements.
The pendant tower is suitable for operating rooms. Automatic lifting or fixed pendants are equipped with various air sources and power interfaces.
According to the different requirements of the hospital, our company has developed various types of terminals and can also modify, design and produce them according to user requirements.
Air pressure monitoring device
The air pressure monitoring box can be installed at the nurse station in the duty room. The pressure gauge indicates the oxygen pressure value of the ward. When the duty staff discovers abnormal oxygen pressure, they can promptly report it to the main station for rapid repair. A portable monitoring box is also available for monitoring terminal pressure at any time.
Main technical indicators and features
The maximum oxygen supply/day is not less than the bottle/day.
Terminal output pressure ~ (adjustable)
The hourly leakage rate of the system is less than
The number of hospital bed terminals is not limited. Regardless of the number of terminals, the terminal pressure and flow requirements are met.
The oxygen cylinder group automatically switches to sound and light alarms. An additional liquid oxygen device can also be connected.
The plug-in self-sealing quick connector for the terminal is easy and reliable to operate.
The main equipment adopts a dual-circuit design and can be inspected without stopping the air.
Disclaimer
The information/pictures/parameters, etc. displayed on this webpage about【Supply central oxygen supply system, central oxygen supply equipment, medical center oxygen supply manufacturer】are provided by member【Rizhao Jieput Air Purification Equipment Engineering Co
】,By Titker Trade Network members 【Rizhao Jieput Air Purification Equipment Engineering Co
】is solely responsible for the authenticity, accuracy and legality of the information/pictures/parameters, etc.,Titker Trade Network only provides display services. For your safety, please choose Titker Trade Network for online trading, otherwise Titker Trade Network will not bear any responsibility for this.
If your legitimate rights and interests have been infringed, please contact Titker Trade Network customer service as soon as possible. We will serve you wholeheartedly. Thank you for your attention and support to Titker Trade Network!