Product Details
1. Fetal heart rate probe: nine chips, wide beam, pulse working mode, high sensitivity.
Ultrasonic intensity: less than
Working frequency:
Signal processing: Dedicated digital signal processing unit
Maximum audio output power:
2. Uterine contraction pressure
Measurement Range: ~Pressure unit
3. Fetal movement mark
Handle-type touch button, screen point recording
4. Probe ultrasonic output
This product meets the requirement of exempting the mid-sound output parameters from publication Conditions, that is, the ultrasonic transducer components and host computer meet the following requirements in all operating modes:
. Peak negative sound pressure (-)<
. Output wave speed sound intensity (b)<
3. Spatial peak time average sound intensity<
5. ECG
Lead selection: all leads, Ⅰ, Ⅱ, Ⅲ,, R,, chest lead display
Gain selection, ,, .Fourth gear
Frequency diagnostic mode.~
Monitoring mode.~
Surgery mode~
Common mode signal suppression diagnostic mode
Monitoring mode
Surgery mode< br/>Scanning speed. /, /, / three standard files.
Heart rate range adult ~ (beats/min)
Newborn/child ~ b (beats/min)
Heart rate accuracy or b, whichever is greater
Calibration signal (peak Peak value, accuracy)
Segment detection measurement range (~+.)
Baseline recovery time in seconds after defibrillation
Alarm mode sound and light alarm
Heart rate alarm preset range: ( Alarm if the preset value is exceeded)
Upper limit ~ times/min adjustable (times/minute)
Children and newborns ~ Br (times/minute)
Accuracy? Br (times/minute)
Resolution Br (times/minute)
Gain selection .,,, four levels
Alarm mode sound and light alarm
Alarm preset range: (alarm if the preset value is exceeded)
Upper limit~ adjustable between times/minute
Lower limit~ Adjustable between times/minute
7. B blood pressure
Technical oscillometric method (pulse wave oscillation method)
Working mode manual/automatic
Measurement unit/
Pass Double safety protection of pressure protection
Adult mode
Children’s mode
Neonatal mode
Blood pressure measurement range and accuracy
Range
Adult systolic blood pressure~
Diastolic blood pressure~
Mean blood pressure~
Children's systolic blood pressure~
Diastolic blood pressure~
Mean blood pressure~
Neonatal systolic blood pressure~
Diastolic blood pressure~
Average pressure~
Static pressure range~
Static pressure accuracy:
Maximum average error of blood pressure accuracy? Maximum standard deviation
Alarm mode sound and light alarm
Alarm preset Range and error: (Alarm when the preset value is exceeded)
Systolic blood pressure upper limit ~ lower limit ~
Diastolic blood pressure upper limit ~ lower limit ~
8. Blood oxygen saturation
Range ~:? ~ : Not defined
Blood oxygen saturation measurement error: ~:? ~: Not defined
Resolution
Pulse count ~ times/minute
Alarm mode: sound and light alarm
/>Alarm preset range and error: (Alarm when the preset value is exceeded)
Upper limit~
Lower limit~
9. Body temperature
Technical high-sensitivity thermistor probe
Body temperature measurement range ℃ ~ ℃
Resolution. ℃
Body temperature accuracy.? (excluding sensor error)
Alarm mode sound and light alarm
Alarm preset range and error: (exceeds Preset numerical alarm)
The upper limit is adjustable between ℃ ~ ℃
The lower limit is adjustable between ℃ ~ ℃
10. Printer (optional)
Specifications: dual channels Thermal array recorder
Printing method: real-time or event-triggered recording of waveforms and text
Resolution: Horizontal: / Vertical:
Comments: Name, gender, date (year/month/day)/ Time (hours)
11. Power supply
Built-in battery (optional) fully sealed maintenance-free super large capacity lithium battery
External AC single AC power supply, , maximum current
Operating temperature ℃ ~ ℃
Operating humidity relative humidity, no condensation
Storage temperature -℃ ~ +℃
Storage humidity relative humidity, no condensation
Altitude. ~ . (working status)
The power consumption of the whole machine is not greater than
12. Safety standards
Comply with international medical safety standards
Comply with B, B, B, -, -, - and - national and industry standards Require.
Disclaimer
The information/pictures/parameters, etc. displayed on this webpage about【GT6800-2 maternal and infant monitor】are provided by member【Hunan Yimin Sunshine Technology Co., Ltd.
】,By Titker Trade Network members 【Hunan Yimin Sunshine Technology Co., Ltd.
】is solely responsible for the authenticity, accuracy and legality of the information/pictures/parameters, etc.,Titker Trade Network only provides display services. For your safety, please choose Titker Trade Network for online trading, otherwise Titker Trade Network will not bear any responsibility for this.
If your legitimate rights and interests have been infringed, please contact Titker Trade Network customer service as soon as possible. We will serve you wholeheartedly. Thank you for your attention and support to Titker Trade Network!