Vehicle tachograph calibration devices, retro-reflective sign test

free member

Split coating thickness gauge (dual use)

total supply
988 台
MOQ
1 台
brand
创宇电子
area
ShandongZibo
Delivery period:
Shipped within 3 days from the date of payment by the buyer
Buyers are still looking
  • 1
  • 2
  • 3
Products Recommended

CTM-2008F series mot

Negotiable

Outer dimension meas

Negotiable

CTM-2002B five-wheel

Negotiable

WYH-1A microcomputer

Negotiable

DGC-100 type ground

Negotiable

Split coating thickn

Negotiable

Shop information

area:Shandong Zibo

Member level:corporate memberYear1

identity:  

Already paid:0.00 yuan deposit

my badge: [Integrity File]

online service:

Business card

Zibo Chuangyu Inspection Co

Applets
【Kind tips】When you call, please mention that you saw us on Titker Trade Network, thank you.
Product Details
< r::/r/~/_ Picture__Split coating thickness gauge
(dual use)
Functional use:
The split coating thickness gauge is a professional Detect the thickness of non-magnetic coatings (such as aluminum, chromium, copper, zinc, tin, enamel, oxide film, rubber, plastic, paint, etc.) on magnetic metal substrates (iron, cobalt, nickel), as well as the thickness of non-magnetic coatings on non-magnetic metal substrates Thickness of non-conductive insulating coating
-/The split coating thickness gauge is an ideal auxiliary manufacturing production tool for paint, anti-corrosion, electroplating, automobile industry, ship transportation, aircraft manufacturing and other related industries. It can work stably in laboratories, workshops and outdoors. At the same time, it can work under the two principles of electromagnetic induction and eddy current to complete the thickness measurement task of different coatings
Can be applied to electroplating layers, paint layers, enamel layers, aluminum tiles, copper tiles, babbitt alloy tiles, It can be used to measure the thickness of phosphating layer, plastic and paper, and can also be used to measure the thickness of hull paint and attachments of underwater structures.
< r::/r/~/_ Picture__3 Technical parameters:
Measuring range: ~
Resolution:. (, probe)
Indication accuracy: ( +) is the thickness of the coating being measured
Display method: *lattice liquid crystal
Storage capacity: can store groups (maximum measurement values per group) measurement data
Unit system: metric, imperial, Can be freely converted
Working voltage: (cell-sized alkaline battery)
Continuous working time: more than 1 hour (when the backlight is not turned on)
Communication interface: B communication interface, which can be connected and communicated with the machine
Overall dimensions:
Overall machine weight:
Operating environment temperature: ℃ ~ + ℃ Relative humidity: no greater than
Minimum thickness of the substrate:
Diameter of the minimum plane of the substrate< br/> Minimum radius of curvature convex:.concave:
Features:
There are a variety of probe types to choose from. By selecting the corresponding probe, you can measure the non-magnetic coating on the magnetic metal substrate. Thickness, and can measure the thickness of the non-conductive coating on the non-magnetic metal substrate
The contact parts of the probe are plated with hard chrome or ruby, which is durable
Automatically identify the probe
The upper and lower limits can be set , when the measurement result is greater than or equal to the upper and lower limits, the instrument will issue a corresponding sound or flashing light prompt.
Prompts errors through screen display or beeps
Equipped with five statistics: average, maximum, minimum, number of tests (.), standard deviation (.) with probe zero point Calibration, one-point calibration, two-point calibration functions, and the basic calibration method can be used to correct the system error of the probe
Optional microcomputer software can be equipped with transmission of measurement results, measurement value storage management, measurement value statistical analysis, and measurement printing. value report and other rich functions
Made of aluminum casing, compact, portable, solid and durable, suitable for harsh operating environments, resistant to vibration, shock and electromagnetic interference
Standard configuration:
Host individual
Probe (/each)
Calibration chip
Zero calibration base (aluminum + iron)
Battery section
Instruction book
Warranty card/qualification Identity
Data cable
Instrument box
Disclaimer

The information/pictures/parameters, etc. displayed on this webpage about【Split coating thickness gauge (dual use)】are provided by member【Zibo Chuangyu Inspection Co 】,By Titker Trade Network members 【Zibo Chuangyu Inspection Co 】is solely responsible for the authenticity, accuracy and legality of the information/pictures/parameters, etc.,Titker Trade Network only provides display services. For your safety, please choose Titker Trade Network for online trading, otherwise Titker Trade Network will not bear any responsibility for this.

If your legitimate rights and interests have been infringed, please contact Titker Trade Network customer service as soon as possible. We will serve you wholeheartedly. Thank you for your attention and support to Titker Trade Network!

Titker Trade Network