Hello and welcome toTitker Trade Network!
Instrumentation, safety protection, electronic electrician

free member

ACS-SD501 type residual current electrical fire monitor

total supply
0
MOQ
0
brand
时域
area
ZhejiangHangzhou City
Delivery period:
Shipped within 3 days from the date of payment by the buyer
Products Recommended

SL-601 Intelligent S

Negotiable

SW-600 wireless temp

Negotiable

SL-603C high-precisi

Negotiable

SS-600 wireless rece

Negotiable

SW-610B wireless tem

Negotiable

SL-603 Intelligent S

Negotiable

Shop information

area:Zhejiang Hangzhou City

Member level:corporate memberYear1

identity:  

Already paid:0.00 yuan deposit

my badge: [Integrity File]

online service:

Business card

【Kind tips】When you call, please mention that you saw us on Titker Trade Network, thank you.
Product Details
Product Number
Product Name

Type Residual Current Electrical Fire Monitor
Product Category
Electrical Fire Monitoring System

Product Description
% Series Electrical Fire Monitoring System Overview With the rapid development of the economy and the continuous improvement of people's living standards, electricity consumption has increased exponentially, but electrical fires have also increased dramatically,
which has also brought great challenges to the national economy and Huge losses were caused to people's lives and property. According to statistics, most electrical fires are caused directly or indirectly by contact arc
short circuits in electrical circuits. Among them, leakage due to aging of distribution lines, damaged cable insulation, and exposed wires are the main causes of contact arc short circuits. Therefore, timely and effective monitoring of electrical fire hazards caused by leakage in distribution lines is a necessary measure to prevent frequent electrical fires. Currently, newly built high-rise buildings must adopt residual current electrical fire monitoring systems in accordance with fire protection design specifications. This is our starting point for developing a cost-effective residual current electrical fire monitoring system.
The series of residual current electrical fire monitoring systems are suitable for electrical fire monitoring in office buildings, hotels, restaurants, corporate factories and residential power distribution lines
. The residual current type electrical fire monitor in the series is an independent monitoring unit that effectively monitors the leakage of distribution lines to the ground and prevents electrical fires caused by leakage of electrical lines to the ground. It is used in conjunction with circuit breakers in distribution lines to effectively monitor and protect ground leakage short circuits.
The model can independently monitor and protect the line leakage of regional power distribution circuits, or it can form a multi-layer monitoring network with repeaters, hubs, serial servers and computers through communication functions to monitor multiple areas and multiple areas. Realize remote real-time monitoring, recording and central monitoring at different levels. The rating of this monitor is adjustable in multiple settings, with high flexibility, simple use and perfect design. Therefore, it is not only suitable for the selection of high-end intelligent buildings, but also especially suitable for the configuration of factories and mines, ordinary commercial buildings and residential buildings.
Function introduction◆.Real-time monitoring
Monitor the leakage current in the monitoring area in real time, and display each monitoring area in real time on the monitor and central monitoring computer
Leakage current value and forecast of distribution lines The alarm threshold value, alarm action value, alarm action time, fault area address and alarm status are displayed on the central monitoring computer
The leakage current change curve and various parameters and status are recorded
◆. Regional monitoring and grouping Network monitoring
The ground leakage current in the protection area can be monitored by an independent monitor, or the monitoring of each area can be hierarchically organized into a network to centrally monitor the residual current pre-alarm threshold, alarm action value, and alarm The action time is adjustable in multiple settings, and can be set on site or remotely
◆. Pre-alarm function
When the real-time leakage current exceeds the rated residual current pre-alarm threshold, the buzzer will alarm , the alarm indicator light flashes
The operator can promptly check the leakage fault point in the alarm area and eliminate the leakage fault, thereby nipping the fire hazard in the bud
◆. Leakage protection function
According to different The regional site and actual conditions require setting the residual current alarm action value and action time to meet
regional leakage protection requirements and avoid overstep tripping or large-area tripping. When the real-time leakage current exceeds the rated residual current alarm action value, an alarm
/>The alarm output can cause the circuit breaker to trip and cut off the power supply
◆. Query function
The cumulative number of alarms can be viewed through the query function
◆. Communication function
Connected through the bus, The protocol can be used to realize data transmission between the monitor and the computer
Technical parameters ◆.Ambient temperature ℃~℃
◆.Ambient relative humidity %, no condensation
◆.Rated voltage %< br/> ◆.Rated frequency
◆.Leakage measurement range~
◆.Measurement accuracy
◆.Display accuracy
◆.Rated residual current alarm action value.,.,. , adjustable /> ◆.Output relay capacitive load/, group, active output
◆.Monitor appearance dimensions.
◆.Zero-sequence transformer aperture, other specifications optional according to cable diameter
/> ◆.Communication method protocol
◆.Installation method wall-mounted
Panel and wiring diagram ◆.Panel and transformer diagram

//~~//
Picture
//~~//
//~~//

Picture
◆. When the monitor provides a /(resistive load )'s active output (~ terminal), so the user can connect an external alarm or other alarm equipment
It can also be used in combination with a shunt tripper and a circuit breaker to achieve the function of cutting off the main circuit. The recommended wiring method See pictures, pictures
//~~//

Pictures
//~~//
Pictures
Networking scheme
◆ Independent monitoring
For a single or a small number of monitors and a short communication distance (), direct connection can be used, as shown below
//~~//
◆Through a repeater Connection
For a single or a small number of monitors but a long communication distance (), they can be connected through a repeater to ensure communication quality, as shown below
//~~//
◆Connect the network through a hub
When there are a large number of monitors and the communication distance is long, they can be connected through a hub, and the hub changes the commonly used serial connection to a star connection to facilitate wiring
//~~//
◆Connect via Ethernet
If you need to convert the serial port form to network form, you can connect the monitor to the computer through the serial port server. The connection method is as shown below
// approximately The picture shows the cooperation of the hub
The serial port server and router can be shared by multiple computers. When the number of monitors exceeds the number of hub or repeater interfaces, the monitors can be connected in series (this method is also applicable to other solutions)
//~~//
"ACS-SD501 type residual current electrical fire monitor"Related Products
Related categories
室内环保检测仪器 Meteorological instruments gas analyzer Chromatograph Rubber and plastic special instruments Test chamber and climate environment equipment Thermometers Pressure instrument biological instrument flow meter Mechanical measuring instruments Experimental equipment Measuring standard instruments valve sensor Measuring tools measuring instrument Weighing instrument Level instrument Display instrument Transmitter Environmental testing instruments Logger counter Industrial timer Control (regulating) instruments Actuator base instrument Testing Machine Analytical Instruments Optical Instruments Electrical instrumentation car instrument Non-destructive testing instruments Electronic measuring instruments Special instrumentation Instruments and accessories Pneumatic unit combination instrument Electric unit instrument cluster Instrument power supply Automated complete control system Centralized control device Inventory instrumentation Packaging testing equipment Second hand instruments Other uncategorized Disinfection machine VOC detection equipment Ray detection equipment Formaldehyde detection equipment Benzene detection equipment Ammonia gas detector Other indoor environmental testing instruments
Related Information
Furnace temperature tester Intelligent temperature and humidity rec MY-WB series guide rail temperature tran Concrete temperature measurement embedde Concrete electronic thermometer Concrete thermometer | Concrete electron KIC explorer oven temperature tester for KIC start2 furnace temperature tester fo Supply German 2D solder paste thickness Supply 3D 6500 solder paste thickness ga Supply of 7-channel KIC furnace temperat KIC 12 channel oven temperature tester f Supply of reflow soldering six-channel o KIC furnace temperature tester for sale Supply of reflow soldering 7-channel ove
Disclaimer

The information/pictures/parameters, etc. displayed on this webpage about【ACS-SD501 type residual current electrical fire monitor】are provided by member【Hangzhou Time Domain Electronic Technology Co., Ltd. Public Search 】,By Titker Trade Network members 【Hangzhou Time Domain Electronic Technology Co., Ltd. Public Search 】is solely responsible for the authenticity, accuracy and legality of the information/pictures/parameters, etc.,Titker Trade Network only provides display services. For your safety, please choose Titker Trade Network for online trading, otherwise Titker Trade Network will not bear any responsibility for this.

If your legitimate rights and interests have been infringed, please contact Titker Trade Network customer service as soon as possible. We will serve you wholeheartedly. Thank you for your attention and support to Titker Trade Network!

Titker Trade Network