Zheng Oil Drilling Rig Electronic Control System Ground Detection Application -
The power configuration, output characteristics, control operation and protection functions of the oil drilling rig electronic control system meet the operating parameters, performance and drilling technology of oil drilling rigs at various depths. Require. Explosion-proof, shock-proof, moisture-proof and fire-proof measures are adopted to meet the requirements for safe operation. The system failure downtime rate that affects drilling operation time is less than. Generally, the diesel generator set is connected to the grid through the control cabinet of the generator set in the system, and AC power is output to the AC busbar
. The drive system adopts a fully digital vector control AC variable frequency speed regulating device. The rectifier unit converts the AC power on the AC busbar into DC power, outputs it to the public DC busbar, and then the inverter unit converts the DC power on the DC busbar into AC power with continuously adjustable voltage and frequency, using a one-to-one method. The control mode drives the AC variable frequency motor.
In this process, a fault ground detection system is required. A fault ground detection system is required to detect AC ground faults. In addition, one ground fault test button is required (mainly used to determine whether the indicator light is burned out when the ground fault indicator light is on). A grounding indication is also required. For this purpose, we designed and selected the second-generation insulation monitor model launched by Dongguan Qianbo Electronic Technology Co., Ltd. This type of insulation monitor has greater versatility, applicability and more powerful functions. It can be used universally in AC and DC environments, and can be applied to power grid environments with larger distributed capacitance. It can completely replace foreign brands.
Type technical parameters
Positive control power supply
Input voltage ~ () or ~ (choose one of the two)
Approximate power consumption
Test network
Power grid Voltage~or~
Set alarm value alarm~alarm~
Internal AC resistance value〉
Internal DC resistance value〉
Internal test voltage +/
Test current ( )
Allowed noise DC voltage
Distributed capacitance
Running time line ground capacitance under line ground capacitance
Measurement accuracy %
Output
Contact group independent The normally open contact corresponds to the group alarm signal
switching capacity, or
energizing capacity, or
analog output~corresponding~ (can be customized according to customer needs)
operating data
Operating mode continuous operation
Operating temperature range.+
℃
Pollution level
Burst immunity/
Control between power lines Surge voltage/
Surge voltage between control power line and ground/
Conducted disturbance immunity
Power frequency magnetic field immunity
Radiated emission limit value level
Degree of protection
Cover/
Terminals/
Technical data
Wiring, high voltage wires,
Wires
Other terminals. Above wires
Install rails or use long screws (recommended)
Weight approx.
br/>
Disclaimer
The information/pictures/parameters, etc. displayed on this webpage about【Insulation monitor sales in Dalian, Liaoning】are provided by member【Dongguan Qianbo Electronic Technology Co., Ltd.
】,By Titker Trade Network members 【Dongguan Qianbo Electronic Technology Co., Ltd.
】is solely responsible for the authenticity, accuracy and legality of the information/pictures/parameters, etc.,Titker Trade Network only provides display services. For your safety, please choose Titker Trade Network for online trading, otherwise Titker Trade Network will not bear any responsibility for this.
If your legitimate rights and interests have been infringed, please contact Titker Trade Network customer service as soon as possible. We will serve you wholeheartedly. Thank you for your attention and support to Titker Trade Network!