Product Details
The type insulation monitor is the third generation insulation monitor developed by our company for the characteristics of large distributed capacitance, high grid voltage, and complex grid in mining, metallurgy and other power grids. Compared with the early insulation monitor, the type intelligent insulation monitor has new features. An independent alarm point reaches an independent insulation resistance setting value and can alarm output. It has a remote test reset function and an analog output function. This type of product can completely replace the advanced European and American imported models and can be used in AC and DC power grids.
Three ground detection applications of the Zheng oil drilling rig electrical control system
The Zheng oil drilling rig electric control system application is aimed at the fault ground detection system, which is used to detect AC ground faults. A ground fault test button is required (mainly used to determine whether the indicator light is burned out when the ground fault indicator light is on). A grounding indication is also required. For this purpose, we designed and selected the second-generation insulation monitor model launched by Dongguan Qianbo Electronic Technology Co., Ltd. Equipped with insulation resistance meter, indicator light and detection button. The insulation detector module and insulation resistance meter selected in the design are installed and connected as shown in Figures 1 and 2.
Positivebr/ Picture 1: The insulation detector is flexible and convenient for rail installation
Positive
Positivebr/ Picture 2 is equipped with an insulation resistance meter, fault indicator light and test button
Positive system After the wiring is correct, conduct pre-debugging and power-on inspections. After the installation and wiring are correct, start power-on debugging. After the main circuit breaker of the incoming line is closed, measure the line voltage and close the power control circuit breaker of the insulation detector. The power light of the insulation detector turns on. Measure the terminal voltage of the insulation detector. At this time, the ground fault light is off. After setting the insulation resistance value and manually pressing the monitoring button, the insulation detector fault light is on, the alarm sounds, the cabinet door ground fault indicator light is on, and the insulation resistance meter displays the resistance value. After reset, the fault light goes out and the running light of the insulation detector indicates normal. The circuit returns to normal duty mode. During the application process, the parameter setting is simple, the dial setting is flexible, and the detection is sensitive. In order to prevent false alarms, it is recommended to set the insulation resistance value appropriately.
Positive
Technical parameters
Control power supply
Input voltage ~ () or ~ (choose one of the two)
Approximate power consumption
Test network< br/> Grid voltage~or~
Set alarm value to alarm~alarm~
Internal AC resistance value〉
Internal DC resistance value〉
Internal test voltage+/
Test current ()〈
Allowed noise DC voltage
Distributed capacitance
Running time line ground capacitance under line ground capacitance
Measurement accuracy %
Output
The contact group independent normally open contact corresponds to the group alarm signal
switching capacity, or
energizing capacity, or
analog output~corresponding~ (can be customized according to customer needs)
operation Data
Operating mode continuous operation
Operating temperature range.+℃
Pollution level
Burst immunity/
Control between power lines Surge voltage/
Surge voltage between control power line and ground/
Conducted disturbance immunity
Power frequency magnetic field immunity
Radiated emission limit value level
Degree of protection
Cover/
Terminals/
Technical data
Wiring, high-voltage conductors,
Conductors
Other terminals. Above conductors
Install on rails or use long screws (recommended)
Weight about
Positive insulation monitor, in many occasions in ungrounded systems, it is necessary to monitor the insulation resistance value of the power grid to the ground. When the insulation resistance value of the power grid to the ground When it drops to a certain level, an alarm is required to take intervention measures. The insulation monitor is designed to meet this demand. The insulation monitor has experienced generations of development. The current insulation monitor can be applied to any occasion in China. The product has strong versatility and is easy to install. Convenience is a domestic model that replaces imported similar insulation monitors.
Positive
Disclaimer
The information/pictures/parameters, etc. displayed on this webpage about【Liaoning Tieling insulation monitoring device manufacturer】are provided by member【Dongguan Qianbo Electronic Technology Co., Ltd.
】,By Titker Trade Network members 【Dongguan Qianbo Electronic Technology Co., Ltd.
】is solely responsible for the authenticity, accuracy and legality of the information/pictures/parameters, etc.,Titker Trade Network only provides display services. For your safety, please choose Titker Trade Network for online trading, otherwise Titker Trade Network will not bear any responsibility for this.
If your legitimate rights and interests have been infringed, please contact Titker Trade Network customer service as soon as possible. We will serve you wholeheartedly. Thank you for your attention and support to Titker Trade Network!