Hello and welcome toTitker Trade Network!
Solution customization of insulation monitors, switch cabinet wire

free member

Liaoning Huludao insulation monitor application and pictures

total supply
1111110 台
MOQ
1 台
brand
乾博
area
GuangdongDongguan city
Delivery period:
Shipped within 7 days from the date of payment by the buyer
Buyers are still looking
  • 1
  • 2
  • 3
Products Recommended

Principles and param

¥1.00/台

Application of insul

¥1.00/台

Insulation monitor s

¥1.00/台

Purchase of insulati

¥1.00/台

Liaoning Huludao ins

¥1.00/台

Liaoning Anshan Insu

¥1.00/台

Shop information

area:Guangdong Dongguan city

Member level:corporate memberYear1

identity:  

Already paid:0.00 yuan deposit

my badge: [Integrity File]

online service:

Business card

Dongguan Qianbo Electronic Technology Co., Ltd.

Applets
【Kind tips】When you call, please mention that you saw us on Titker Trade Network, thank you.
Product Details
Three applications for ground detection of oil drilling rig electrical control systems
The application of positive drilling rig electrical control systems is aimed at fault ground detection systems, which are used to detect AC ground faults. A ground fault test button is required (mainly used to determine whether the indicator light is burned out when the ground fault indicator light is on). A grounding indication is also required. For this purpose, we designed and selected the second-generation insulation monitor model launched by Dongguan Qianbo Electronic Technology Co., Ltd. Equipped with insulation resistance meter, indicator light and detection button. The insulation detector module and insulation resistance meter selected in the design are installed and connected as shown in Figures 1 and 2.
Positivebr/ Picture 1: The insulation detector is flexible and convenient for rail installation
Positive
Positivebr/ Picture 2 is equipped with an insulation resistance meter, fault indicator light and test button
Positive system After the wiring is correct, conduct pre-debugging and power-on inspections. After the installation and wiring are correct, start power-on debugging. After the main circuit breaker of the incoming line is closed, measure the line voltage and close the power control circuit breaker of the insulation detector. The power light of the insulation detector turns on. Measure the terminal voltage of the insulation detector. At this time, the ground fault light is off. After setting the insulation resistance value and manually pressing the monitoring button, the insulation detector fault light is on, the alarm sounds, the cabinet door ground fault indicator light is on, and the insulation resistance meter displays the resistance value. After reset, the fault light goes out and the running light of the insulation detector indicates normal. The circuit returns to normal duty mode. During the application process, the parameter setting is simple, the dial setting is flexible, and the detection is sensitive. In order to prevent false alarms, it is recommended to set the insulation resistance value appropriately.
Positive technical parameters
Control power supply
Input voltage ~ () or ~ (choose one of the two)
Approximate power consumption
Test network
Power grid Voltage~or~
Set alarm value alarm~alarm~
Internal AC resistance value〉
Internal DC resistance value〉
Internal test voltage +/
Test current ( )
Allowed noise DC voltage
Distributed capacitance
Running time line ground capacitance under line ground capacitance
Measurement accuracy %
Output
Contact group independent The normally open contact corresponds to the group alarm signal
switching capacity, or
energizing capacity, or
analog output~corresponding~ (can be customized according to customer needs)
operating data
Operation mode: continuous operation
Operating temperature range.+℃
Pollution level

Burst immunity/
Control of surge voltage between power lines/
Control the surge voltage between the power line and the ground/
Conducted disturbance immunity
Power frequency magnetic field immunity
Radiated emission limit value level
Degree of protection
Cover/
Terminals/
Technical data
Wiring, high-voltage wires,
Wires
Other terminals. Above wires
Install rails or use Long screw installation (recommended)
Weight approx.

"Liaoning Huludao insulation monitor application and pictures"Related Products
Related categories
室内环保检测仪器 Meteorological instruments gas analyzer Chromatograph Rubber and plastic special instruments Test chamber and climate environment equipment Thermometers Pressure instrument biological instrument flow meter Mechanical measuring instruments Experimental equipment Measuring standard instruments valve sensor Measuring tools measuring instrument Weighing instrument Level instrument Display instrument Transmitter Environmental testing instruments Logger counter Industrial timer Control (regulating) instruments Actuator base instrument Testing Machine Analytical Instruments Optical Instruments Electrical instrumentation car instrument Non-destructive testing instruments Electronic measuring instruments Special instrumentation Instruments and accessories Pneumatic unit combination instrument Electric unit instrument cluster Instrument power supply Automated complete control system Centralized control device Inventory instrumentation Packaging testing equipment Second hand instruments Other uncategorized Disinfection machine VOC detection equipment Ray detection equipment Formaldehyde detection equipment Benzene detection equipment Ammonia gas detector Other indoor environmental testing instruments
Related Information
Beijing functional testing tooling Handheld intelligent signal generation c ESKH switching leakage current sensor ES008 clamp-type AC current sensor ES020 portable CT clamp-shaped structure ES050 high harmonic current sensor ES050HV high voltage line current sensor ES3035E digital insulation resistance me ES5000 Clamp Current Recorder ES5001 clamp-on SD card current recorder ES3025 digital insulation meter ES3025E electric rocking watch ES3000 digital ground grid ground resist ES3001 digital ground soil resistivity t ES3002 Intelligent Ground Resistance Det
Disclaimer

The information/pictures/parameters, etc. displayed on this webpage about【Liaoning Huludao insulation monitor application and pictures】are provided by member【Dongguan Qianbo Electronic Technology Co., Ltd. 】,By Titker Trade Network members 【Dongguan Qianbo Electronic Technology Co., Ltd. 】is solely responsible for the authenticity, accuracy and legality of the information/pictures/parameters, etc.,Titker Trade Network only provides display services. For your safety, please choose Titker Trade Network for online trading, otherwise Titker Trade Network will not bear any responsibility for this.

If your legitimate rights and interests have been infringed, please contact Titker Trade Network customer service as soon as possible. We will serve you wholeheartedly. Thank you for your attention and support to Titker Trade Network!

Titker Trade Network