Micro-expansion grouting material manufacturer, high-strength grouting material price, secondary grouting material
Grouting material manufacturer, grouting material price, high-strength non-shrinkage grouting material, grouting material manufacturer
>High-strength non-shrinkage grouting material is a cement-based Self-flowing micro-expansion dry mortar has the characteristics of early strength, high strength, self-flow and micro-expansion. It is suitable for the reinforcement and reconstruction of secondary grouting concrete structures of equipment foundations and the anchoring of anchor bolts.
Product Features
Strong and high-strength, the compressive strength can reach above 100, and the bolts can be tightened and tested within hours after grouting. The highest day intensity can reach above.
It has high self-flowing properties and can be used by adding water and stirring on site. It can fill all gaps without vibrating.
There is no shrinkage after expansion grouting, ensuring close contact between equipment bolts and foundation.
Seasonal construction allows outdoor construction to be carried out at a minimum temperature of ℃.
Durability: This product is an inorganic cementing material, and its service life is longer than the service life of the base concrete. After tens of thousands of fatigue tests
freeze-thaw cycle tests, there is no obvious change in strength.
Resistant to oil penetration and high temperature impact. After being immersed in engine oil, the strength is higher than before being immersed in oil. After planting, flame cutting and welding of the steel bars are allowed.
Scope of application
General reinforcement type
Grouting thickness << secondary grouting of equipment foundation, anchor bolt anchoring, embedded steel bars, reinforcement of building beams, plate column foundations and floors Reinforcement.
Pisolite reinforced type
Contains large aggregate, suitable for grouting layer thickness, and grouting length < secondary grouting of equipment foundation. Reinforcement and reinforcement (repair thickness) of the building's beam-slab-column foundation and floor.
Ultra-fine reinforced type
Ultra-fine aggregate, suitable for secondary grouting of equipment foundations and steel structure column footings with grouting layer thickness <<. The gaps between the concrete beams and columns reinforced angle steel and the concrete are grouted.
Super early-strengthening type
The hourly strength is reached, and it is suitable for rapid repairs such as railway sleepers, rapid repairs of cement concrete pavements, airport runways, etc., and rapid repairs of water-stopping and leakage.
>Technical indicators
Comply with/standard indicators ℃ standard curing test block size
Project
Model
Vertical
Expansion rate
Compressive strength
Fluidity
Slump
Minimum construction temperature (℃)
Reference
Water consumption
Bulk weight
Days
Day
Day
Universal reinforced type
Pisolite reinforced type
Ultra-fine reinforced type
Project
Model
Vertical
Expansion rate
Compressive strength
Fluidity
Slump
Reference water consumption
Bulk weight
Hours
Days
Days
Super early strengthening type
>Strength conversion relationship between various trial mold sizes
Trial mold dimensions
Strength ratio
Age
Day
Day
Day
Pack into specifications/bags, store in a ventilated and dry place and prevent direct sunlight.
The shelf life is one month. If it exceeds the shelf life, it must be re-inspected before it can be used.
>Beijing Borui Shuangjie New Technology Co., Ltd. is mainly engaged in high-strength non-shrinkage grouting materials, epoxy resin-type grouting materials, high-strength wear-resistant materials, ultra-high-strength road repair mortar
Epoxy repair mortar, track cement, steel bar anchoring materials, once Seat slurry Bearing mortar grouting resin concrete recasting agent_ /__Interface agent
Dry powder interface agent patching mortar reinforcement planting glue flexible cement caulking material polymer waterproof mortar steel bar embroidery resistance agent construction glue (concentrated powder) Steel adhesive, carbon cloth adhesive, ceramic tile adhesive, and other construction site construction materials_/__ Direct sales from
manufacturers.
>Grouting material Grouting material Grouting material is formulated with high-strength materials as aggregates, cement as binding agent, and supplemented by high-fluid micro-expansion anti-segregation and other substances. It can be used after adding a certain amount of water at the construction site and stirring evenly. In terms of construction, it has the advantages of reliable quality, reduced cost, shortened construction period and easy use.
Product features of grouting material
High strength
The compressive strength can reach above 100, and the bolts can be tightened and tested within hours after grouting. The highest day intensity can reach above.
It has high self-flowing properties and can be used by adding water and stirring on site. It can fill all gaps without vibrating.
There is no shrinkage after expansion grouting, ensuring close contact between equipment bolts and foundation.
Seasonal construction allows outdoor construction to be carried out at a minimum temperature of ℃.
Durability: This product is an inorganic cementing material, and its service life is longer than the service life of the base concrete. After tens of thousands of fatigue tests
freeze-thaw cycle tests, there is no obvious change in strength.
Resistant to oil penetration and high temperature impact. After being immersed in engine oil, the strength is higher than before being immersed in oil. After planting, flame cutting and welding of the steel bars are allowed.
Scope of application of grouting materials
Universal reinforcement type
Grouting thickness << secondary grouting of equipment foundation, anchor bolt anchoring, buried steel bars, building beams, slabs, column foundations and floors Reinforcement.
Pisolite reinforced type
Contains large aggregate, suitable for grouting layer thickness, and grouting length < secondary grouting of equipment foundation. Reinforcement and reinforcement (repair thickness) of the building's beam-slab-column foundation and floor.
Ultra-fine reinforcement type
Ultra-fine aggregate, suitable for secondary grouting of equipment foundations and steel structure column footings with grouting layer thickness
. The gaps between the concrete beams and columns reinforced angle steel and the concrete are grouted.
Super early-strengthening type
The hourly strength is reached, and it is suitable for rapid repairs such as railway sleepers, rapid repairs of cement concrete pavements, airport runways, etc., and rapid repairs of water-stopping and leakage.
>The technical indicators of high-strength non-shrinkage grouting material conform to/standard indicators ℃ standard curing test block size
Project
Model
Vertical
Expansion rate
/> Compressive strength
Fluidity
Slump
Minimum construction temperature (℃)
Reference
Water consumption
Bulk weight
Days< br/> Day
Day
Universal reinforced type
Pisolite reinforced type
Ultra-fine reinforced type
Project
Model
Vertical
/> Swelling rate
Compressive strength
Fluidity
Slump
Reference water consumption
Bulk weight
Hours
Days
Day
Super early reinforcement
Type
>Strength conversion relationship between various trial mold sizes
Trial mold size
Strength ratio
Age Period
Day
Day
Day
>Grouting material grouting construction instructions
>1 Foundation treatment
>The foundation surface should be roughened . Clean the surface of the foundation. There should be no gravel, floating ash, oil, dirt, release agent and other debris. The surface of the foundation should be fully moistened one hour before grouting, and any accumulated water should be removed one hour before grouting.
Two formwork
Set up the formwork according to the grouting construction drawing. The joints between the formwork and the basic formwork should be sealed with cement slurry tape to ensure that the entire formwork is watertight.
The horizontal distance between the formwork and the equipment base should be controlled to the left and right to facilitate grouting
construction.
The top elevation of the formwork should be higher than the upper surface of the equipment base.
If grouting occurs during grouting, it should be dealt with in time.
Grouting material 3_/__Grouting material
Preparation
Generally, add water and stir according to the standard of general_/__reinforced type
, and add water and stir according to the standard of pisolite reinforced type. Stir.
_ /__High Strength
The mixing of non-shrinkage grouting materials can be done mechanically or manually. It is recommended to use a forced mixer for mechanical mixing, which can ensure sufficient and even mixing and the mixing time is minutes. Manual mixing time is completed within minutes. The fluidity of the mixed grouting material will decrease as the parking time increases, and it should be used up within minutes. It is strictly prohibited to mix any _ /__ admixture
into the high-strength non-shrinkage grouting material.
Four grouting construction methods of grouting materials
For longer equipment or track foundations, segmented construction should be used.
After grouting begins, it must be carried out continuously without interruption, and the grouting time should be shortened as much as possible.
Five maintenance steps for high-strength non-shrink grouting material
After grouting is completed, the grouting material should be covered with a straw bag or rock wool quilt immediately after initial setting and kept moist.
During winter construction, the grouting material mixing water and maintenance measures should comply with the relevant provisions of the current "Construction Quality Acceptance Code for Concrete Structure Engineering".
_ /____
Do not subject to vibration for hours after grouting to avoid damaging the unhardened grouting layer.
The relationship between grouting material form removal, curing time and ambient temperature
Daily minimum temperature (℃)
Membrane removal time
Curing time
>Grouting material
Packaging, Storage and Transportation
Pack into specifications/bags and store in a ventilated and dry place away from direct sunlight.
The shelf life is one month. If it exceeds the shelf life, it must be re-inspected before it can be used.