Product Details
High-strength non-shrinkage grouting material
>High-strength non-shrinkage grouting material is a cement-based self-flowing micro-expansion dry mortar. It has the characteristics of early strength, high strength, self-flow and micro-expansion, and is suitable for equipment foundations. Secondary grouting, reinforcement and transformation of concrete structures, anchoring of steel bars and anchor bolts, etc.
Product Features
The compressive strength of early and high strength can reach above. The bolts can be tightened and tested within hours after grouting. The highest day intensity can reach above.
It has high self-flowing properties and can be used by adding water and stirring on site. It can fill all gaps without vibrating.
There is no shrinkage after micro-expansion grouting, ensuring close contact between equipment, bolts and foundation.
In winter, outdoor construction is allowed to be carried out at a minimum temperature of ℃.
Durability: This product is an inorganic cementing material, and its service life is longer than the service life of the base concrete. After tens of thousands of fatigue tests and freeze-thaw cycles, there is no obvious change in strength.
. Resistance to oil penetration and high temperature impact. After being immersed in engine oil, the strength is higher than before being immersed in oil. Flame cutting and welding of the steel bars are allowed after planting.
Scope of application
Universal reinforcement type
Grouting thickness << secondary grouting of equipment foundation, anchor bolt anchoring, buried steel bars, building beams, plates, Reinforcement of columns, foundations and floors.
Pisolite reinforced type
Contains ~ large aggregate, suitable for grouting layer thickness, and grouting length < secondary grouting of equipment foundation. Reinforcement (repair thickness) of beams, slabs, columns, foundations and floors of buildings.
Ultra-fine reinforced type
Ultra-fine aggregate is suitable for secondary grouting of equipment foundations and steel structure column footings with grouting layer thickness <<. The gaps between the concrete beams and columns reinforced angle steel and the concrete are grouted.
Super early reinforcement type
Hourly strength is reached, suitable for rapid repairs such as railway sleepers, rapid repair of cement concrete pavements, airport runways, etc., and water stopping Quick leak repair.
>Technical indicators
Comply with/standard indicators ℃ standard maintenance, test block size,
Project
Model
< br/> Vertical
Expansion rate
Compressive strength
Fluidity
Slump
Minimum construction temperature (℃)
Reference
Water consumption
Bulk weight
Day
Day
Day
Universal reinforced type
~
Pisolite reinforced type
/>
~
Ultra-fine reinforcement Type
< br/>
~
Item
Model
Vertical
Expansion rate
Compressive strength
Fluidity
Slump
Reference water consumption
Test weight
Hours
Days
Days
< br/> Super early reinforcement type
/>
~
>Strength conversion relationship between various trial mold sizes
Try Mold size
Strength ratio
Age
days
days
day
< br/>
>Grouting construction instructions
>1. Foundation treatment
/>>The base surface should be roughened. Clean the foundation surface. There should be no gravel, floating slurry, floating ash, oil stains, release agents and other debris. The foundation surface should be fully moistened one hour before grouting. Remove any accumulated water one hour before grouting.
2. Formwork support
Set up the formwork according to the grouting construction drawing. The joints between the formwork and the foundation, and between the formwork and the formwork are sealed with cement slurry, tape, etc. to ensure that the entire formwork is watertight.
The horizontal distance between the formwork and the equipment base should be controlled to the left and right to facilitate grouting construction.
The top elevation of the formwork should be higher than the upper surface of the equipment base.
If grout running occurs during grouting, it should be dealt with in time.
3. Preparation of grouting material
Generally, add water and stir according to the standard for general reinforced type, and add water and stir according to the standard for pisolite reinforced type.
Mechanical or manual mixing can be used to mix high-strength non-shrinkage grouting materials. It is recommended to use a forced mixer for mechanical mixing, which can ensure sufficient and even mixing and the mixing time is minutes. Manual mixing time is completed within minutes. The fluidity of the mixed grouting material will decrease as the parking time increases, and it should be used up within minutes. It is strictly prohibited to mix any additives into high-strength non-shrinkage grouting materials.
4. Grouting construction method
For long equipment or track foundation, segmented construction should be used.
After the grouting starts, it must be carried out continuously without interruption, and the grouting time should be shortened as much as possible.
5. Maintenance
After grouting is completed, the grouting material should be covered with a straw bag or rock wool quilt immediately after initial setting and kept moist.
During winter construction, grouting materials, mixing water and maintenance measures should comply with the relevant provisions of the current "Construction Quality Acceptance Code for Concrete Structure Engineering".
Do not subject to vibration for hours after grouting to avoid damaging the unhardened grouting layer.
The relationship between mold removal, curing time and ambient temperature
Daily minimum temperature (℃)
Membrane removal time
Curing time
< br/> ~
~
< br/> ~
>Packaging, Storage and Transportation
Packaging specifications/bag, stored in a ventilated and dry place and protected from direct sunlight.
The shelf life is one month. If it exceeds the shelf life, it should be re-inspected before it can be used.
>The product packaging is subject to actual delivery. This picture is for reference only.
Disclaimer
The information/pictures/parameters, etc. displayed on this webpage about【Shantou high strength non-shrinkage grouting material factory direct sales】are provided by member【Beijing BORI Shuangjie New Technology Co
】,By Titker Trade Network members 【Beijing BORI Shuangjie New Technology Co
】is solely responsible for the authenticity, accuracy and legality of the information/pictures/parameters, etc.,Titker Trade Network only provides display services. For your safety, please choose Titker Trade Network for online trading, otherwise Titker Trade Network will not bear any responsibility for this.
If your legitimate rights and interests have been infringed, please contact Titker Trade Network customer service as soon as possible. We will serve you wholeheartedly. Thank you for your attention and support to Titker Trade Network!