Hello and welcome toTitker Trade Network!
Mining Equipment Machine Parts|Conveyor Supporting Machinery|Elect

free member

Anti-overflow skirt installation_Double-sealed anti-overflow skirt price and size

total supply
0
MOQ
0
area
ShandongJining City
Delivery period:
Shipped within 3 days from the date of payment by the buyer
Buyers are still looking
  • 1
  • 2
  • 3
Products Recommended

KBF-600/28 mine expl

Negotiable

DC generator, ZFB-50

Negotiable

Old factory electro-

Negotiable

Accessories_buffer s

Negotiable

Supply motor_motor f

Negotiable

Supply MW friction p

Negotiable

Shop information

area:Shandong Jining City

Member level:corporate memberYear1

identity:  

Already paid:0.00 yuan deposit

my badge: [Integrity File]

online service:

Business card

Jining Guolong Material Company

  • name:王晶(lady) 
  • phone:0537-3282848
  • mobile phone:15263730467
  • address:济宁市市中区
Applets
【Kind tips】When you call, please mention that you saw us on Titker Trade Network, thank you.
Product Details
Installation of anti-overflow skirt
Price and size of anti-overflow skirt
The anti-overflow skirt of the guide trough is a double-layer structure. It is installed on the lower edge of the belt conveyor guide trough through a set of quick pressing devices. Seal between conveyor belt and guide trough.
Double-layer sealing, the inner layer isolates materials from spilling, and the outer layer suppresses dust flying.
The polyurethane wear-resistant layer is compounded on the parts in contact with the belt, which has a long service life and does not damage the belt.
Quick clamping device makes installation and adjustment convenient and quick
Installation instructions
The clamp is used in conjunction with the angle aluminum, and two sets of clamps are used per meter.
The height of the anti-overflow skirt can be adjusted appropriately according to the actual size of the guide trough.
Production capacity
Type anti-overflow skirt
Type anti-overflow skirt
Technical features of double seal anti-overflow skirt
In order to solve the problems existing in the sealing of ordinary guide trough According to the operating characteristics of the belt and the structure of the guide trough, our company's technical staff successfully developed a double-sealed anti-overflow skirt, which fundamentally solved the problem of coal spillage, air leakage and powder leakage on both sides of the guide trough, and played an important role in reducing the dust concentration in the belt corridor. played an important role. The device is installed on site as shown below.
The technical features of the double-sealed anti-overflow skirt are as follows
The skirt is made of polyurethane and natural rubber, and polyurethane plays the main sealing role in the part in contact with the belt. Polyurethane is cast from high-quality imported powder. Compared with polyurethane made by extrusion process, it has better wear resistance, longer service life and does not damage the belt.
Sealing effect: The anti-overflow skirt adopts a straight plate + skirt double-layer sealing integrated structure. The straight plate is close to the side of the guide trough, and the bottom is in contact with the belt to prevent material from overflowing. The skirt can be turned outwards within a certain angle. Rotation, relying on the elasticity of the rubber plate, automatically tracks the belt, always maintains close contact with the belt, and has excellent sealing performance.
The skirt sealing part of the skirt board adopts a single-sided arc transition. When the belt goes off track, it will not damage the belt and skirt and can automatically return to its original state.
The skirt panels on each side of the guide trough are made into a whole as required and are the same length as the guide trough to prevent air leakage at the joints.
Problems with the sealing of ordinary guide troughs
At present, the sealing strips on both sides of the guide trough are mostly cut from ordinary rubber belts and fixed with the guide trough through angle steel wedge locking devices. The main problems with this sealing method are: poor wear resistance of the sealing strip. After being used for a short period of time, the sealing strip is severely worn, and the sealing strip cannot be in close contact with the belt. The sealing effect is poor, air leakage and powder leakage are serious, the dust on site is large, and the environment is harsh.
The sealing strip has no up and down deformation. The sealing strip installed when the belt is stationary, once fixed, will cause a gap between the sealing strip and the belt when the belt carries material and sinks, causing a serious phenomenon of coal and powder spillage.
The sealing strip is a single seal, which is not as effective as a double seal.
Disclaimer

The information/pictures/parameters, etc. displayed on this webpage about【Anti-overflow skirt installation_Double-sealed anti-overflow skirt price and size】are provided by member【Jining Guolong Material Company 】,By Titker Trade Network members 【Jining Guolong Material Company 】is solely responsible for the authenticity, accuracy and legality of the information/pictures/parameters, etc.,Titker Trade Network only provides display services. For your safety, please choose Titker Trade Network for online trading, otherwise Titker Trade Network will not bear any responsibility for this.