Performance characteristics of series of high temperature smoke exhaust fans for fire protection
Series of high temperature smoke exhaust fans are national-level Spark project products, with excellent performance, good high temperature resistance, high efficiency, high floor space ratio, centrifugal The fan is less and easy to install.
The installation methods of fire fans can be divided into horizontal type and hall type. If you have special requirements for air volume, full pressure, installation size and other performance, our factory will design and produce it separately for you.
The performance listed in the performance table of the fire blower is the performance within the highest efficiency range and is divided into five performance points according to the air volume. The performance table shall prevail when selecting. The factory-qualified fire fans are under rated air volume, and the total pressure value error does not exceed the performance selection table, which is the performance under the standard state. Regardless of the performance required by the technical documents or ordering, the performance is subject to the standard state.
Silenced fire-fighting high-temperature smoke exhaust fans, users can choose different types according to actual needs
It means that the normal pressure type fire-fighting high-pressure smoke exhaust fan is specially purchased. The blade type adopts axial flow type and has a single-speed fire blower. , Two types of two-speed fire fans
The fire fans have excellent high temperature resistance. The fan test meets the requirements of fire protection standards. An enterprise internal control assurance system higher than this standard has been established. It can run continuously for more than 10 minutes under high temperature conditions of ℃. It lasts for hours/times without damage and is widely used in high-end civil buildings, ovens, underground garages, tunnels and other occasions.
It is a special fan for roof-type firefighting and high-temperature smoke exhaust. Users can choose flame-retardant fiberglass wind building or steel hood according to actual needs.
It is a special fire blower for low-pressure and high-temperature smoke exhaust.
Installation Instructions
When installing the fan, a comprehensive inspection of all components should be carried out to see if the parts are complete and whether the connections of the components are tight. When installing the fire smoke exhaust fan, pay attention to maintaining the horizontal position of the fan and ensuring the connection between the fan and the foundation. The connection between the surface and the air outlet pipe should be adjusted to make it fit naturally, and there should be no forced connection. It is not allowed to add the weight of the pipe to the parts of the fan.
If the fire smoke exhaust fan is found to have abnormal phenomena such as severe vibration and impact during operation, it must be stopped immediately for inspection.
Rainproof measures should be taken when the fan is used in the open air.
Remove dust, dirt and other impurities inside the fan regularly to prevent rust.