Standby diesel generator set Maintenance of diesel generator sets consists of multiple systems. In the process of maintaining them, it is necessary to start with the maintenance of each system: maintenance of the start-up system of the standby diesel generator set. In the standby stage, it is in a standby state, but Because the backup diesel generator set is a backup power source, the integrity and safety of the starting system are very important during emergency start. For this reason, it is necessary to strengthen the maintenance and upkeep of the backup diesel generator set. The starting of the diesel generator set relies on the battery, so it is necessary to strengthen the maintenance and upkeep of the diesel generator set battery. When the battery is in standby state, it needs to reach the rated voltage. Therefore, in daily maintenance and management, it is necessary to strengthen the monitoring of the voltage of the diesel generator battery battery. When charging it, when the voltage of the battery reaches the rated voltage, the charging will stop. If the voltage is lower than the rated voltage, it will automatically charge. For this purpose, it is necessary to monitor the voltage of the battery and set up automatic charging equipment. During the maintenance of the diesel generator battery, attention needs to be paid to the internal components of the battery. If the performance of the electrolyte inside the battery decreases, it needs to be replenished in time. The terminals corroded by the electrolyte must also be replaced in time.
.
. Daze Power
Detailed parameters
Open posture diesel generator
. 1. Technical specifications
. Product number' '
. Rated output' ':
. Maximum power' ':
. Rated frequency' ':
. Rated voltage' ':
. Number of phases:
Single phase
. Starting method: electric start
. Power factor:
. Regulation method ' '
(automatic voltage regulator)
.
. Engine technical parameters:
. Power model' '
. Displacement' '
. Type: horizontal bar air-cooled four-stroke
. Cooling method: forced air cooling
. Noise level' '
( ' '
)' '
. Oil supply method: direct injection
. Speed control method: electronic speed control
. Oil model' '
. Fuel model' '
' '
Light diesel
. Diesel fuel tank' '
. Unit fuel consumption' '
' '
. Lubricating oil tank' '
. Unit continuous running time' '
' '
.
. Motor technical parameters' ':
. Motor model' '
. Rated current' '
. Insulation level' '
Level
.
. Other configurations:
. Unit Overall dimensions (
' '
): **
Unit weight (
' '
):
. Battery capacity:
. Low The oil pressure alarm system automatically shuts down the engine.
. Electric start ensures that the unit can start quickly.
. New automatic voltage regulator ensures stable voltage output.
. Price of emergency diesel generator for power outage before starting up
Preparation Clean the surface of the unit to make sure there is no dust or oil stains
. Clean and check the machine room again to ensure that there are no flammable or explosive items around the unit
. Check the diesel fluid level. Check the engine oil dipstick to ensure that the fluid level is between the two scales and as close to the upper limit as possible without exceeding the check water tank fluid level, preferably just under the filler cap.
. Ensure that the quality of diesel and engine oil used by the unit is not lower than the requirements in the data.
. Confirm that there is no leakage in the diesel oil pipe connection in and out of the machine body and no air entering.
. Loosen the bleed screw on the high-pressure oil pump, pump oil by hand until oil is sprayed at the bleed screw, and then tighten the bleed screw.
. Comprehensively check and ensure that the electrical and control parts are connected correctly, reliably and without aging.
. Ensure that the air in and out of the computer room is smooth and unobstructed. Check whether the battery power is sufficient. If it cannot meet the starting requirements, it should be recharged until it is full.
. Check whether the fuel system, cooling system and lubricating oil seal of the unit are leaking
. Make sure the air filter is not blocked
. Connect the power output cable correctly to ensure there is no leakage. No shortcomings or wrong phases.
. Check the reliability of the fasteners and throttle adjustment system, and confirm that the operating mechanism is flexible and light
. Check the tightness of the water pump belt, charger belt and fan belt.
. Check whether the switch on the control panel operates flexibly and works reliably. Check whether the generator output circuit connection is correct. Make sure the B (air switch) position is with the handle down. Make sure that the charging and starting electrical circuit connections are in good contact and are not loose or falling off.
Disclaimer
The information/pictures/parameters, etc. displayed on this webpage about【6kw three-phase open frame diesel generator price】are provided by member【Shanghai Obao Power Co
】,By Titker Trade Network members 【Shanghai Obao Power Co
】is solely responsible for the authenticity, accuracy and legality of the information/pictures/parameters, etc.,Titker Trade Network only provides display services. For your safety, please choose Titker Trade Network for online trading, otherwise Titker Trade Network will not bear any responsibility for this.
If your legitimate rights and interests have been infringed, please contact Titker Trade Network customer service as soon as possible. We will serve you wholeheartedly. Thank you for your attention and support to Titker Trade Network!