2
Temperature measurement: Range: room temperature ~ ℃
Repeatability ℃
Reproducibility ℃
Resolution: ℃
Accuracy: %
Heating rate: in line with B/standard
Ignition method: electronic ignition, gas flame㎜~㎜
Environment Temperature: (~)℃
Relative humidity %
Machine power consumption: no greater than.
3< Fully Automatic Open Flash Point Tester Instrument Features
This instrument uses a color LCD large screen display, a full Chinese human-computer dialogue interface, an unmarked keyboard, and can pre-value the temperature of the sample and the atmospheric pressure Strong test date and other parameters, with prompt menu-oriented input function.
The simulation traces and displays the function curve of temperature rise and test time. It has a Chinese misoperation software prompt modification function, and is equipped with a parameter prompt function such as test date and test time.
Automatically correct the influence of atmospheric pressure on the test and calculate the correction value.
Differential detection and automatic correction of system deviations.
The swipe detection and printing data are automatically completed, and the test arm automatically rises and falls.
Electronic ignition, forced air cooling (note: the manual ignition button is located on the left side of the instrument box).
Equipped with standard R, computer interface, the lower computer stores historical data. It can store large-capacity data and save it for a long time when connected to the computer. After transmitting the data, the upper computer can modify the parameters of the lower computer in real time
Four
Continue the test until the lowest temperature at which the test flame ignites the sample and burns it for at least 2 seconds is regarded as the ignition point of the sample.
This instrument consists of a single-chip computer and peripheral circuits to form a signal acquisition, processing, calculation, output control and other systems. When working, according to the temperature changes collected by the sensor, instructions are issued to control the heater, so that the sample temperature rises at a certain rate, scanning cycle ignition time differential detection, etc. are all automatically controlled.
When the flash point is measured, the computer system stops data collection, displays the flash point temperature and prints the record results. If you need to continue testing the ignition point, the instrument continues to heat. When the ignition point is measured and burns for seconds, the cover automatically Turn off the flame, the big arm will automatically lift up, and the experiment is over.
Complete set of five fully automatic open flash point testers
Complete set of instruments
> < > Serial number
> Name
> Unit
> Quantity
< >
>
> Desk
>
< >
> Oil cup
> pieces
/>
>
< >
> Power cord ( )
> Root
>
< >
> Printing paper
> Roll
>
< >
> Ignition head
> Individual
>
< br/>