The Halogen Rapid Moisture Analyzer adopts the principle of halogen lamp pyrolysis gravimetric and is a rapid moisture detection instrument. While the moisture meter measures the weight of the sample, the halogen lamp heating unit and moisture evaporation channel quickly dry the sample. During the drying process, the moisture meter continuously measures and instantly displays the moisture content lost by the sample. After the drying process is completed, the final measured moisture content The value is displayed locked. Compared with the international oven heating method, halogen heating can reach the maximum heating power in the shortest time, and the sample is quickly dried at high temperature. Its detection results are in good consistency with the national standard oven method, it is replaceable, and the detection efficiency is much higher in the oven method. Generally, samples can be measured in just a few minutes. The operation is simple and the test is accurate. It can display moisture value, dryness value, measurement time, temperature value, and other data. And has the function of connecting with computers and printers.
2. Precautions:
The halogen rapid moisture analyzer is used to measure the moisture content in samples. Any other use may cause personal injury and damage the instrument.
Please be sure to read the instructions carefully before use, and do not use it under environmental conditions that do not meet the requirements.
The Halogen Rapid Moisture Analyzer should only be used by trained professionals who are familiar with the properties of the sample.
The power supply of the halogen rapid moisture analyzer is a three-plug grounded socket. It is forbidden to disconnect the ground wire of the instrument or use a power supply without good grounding.
There should be enough space around the instrument to avoid heat accumulation and overheating.
Since the area around the heating unit around the instrument will become hot, please do not place flammable items around the instrument.
After the test, since the sample itself, the heating unit and its container will still be very hot, care should be taken when removing the sample.
During the heating and drying process, the temperature of the annular heating element will reach ℃. Therefore do not open or touch the heating unit. If you need to open it, disconnect the power supply and wait until it cools down completely.
Be especially careful with flammable or flammable items, solvent-containing matrices, and matrices that produce flammable or explosive gases when heated, because these samples may cause harm to the human body or damage equipment. Therefore, when measuring such samples, the operating heating temperature should be low enough to prevent the formation of flames or explosives, and protective equipment such as goggles should be worn. If the flammability of the sample is not well understood, the test sample size should be as small as possible. In this case, the instrument should be supervised by a dedicated person just in case, and please do a risk analysis by yourself before the experiment.
For substrates containing toxic elements, this substrate can only be heated and dried under conditions with good ventilation equipment.
, a matrix that generates corrosive steam when heated and dried. When measuring samples of this matrix, because the steam will condense on the cooler part of the shell and cause corrosion, it is recommended to reduce the sample weight.