Product Details
Heilongjiang Province Cooling Tower Installation Lightning Rod Manufacturer Repair Lightning Rod Unit
Chimney Installation Hoop Reinforcement Replacement Lightning Rod Maintenance Construction Company Manufacturer Unit
Heilongjiang Province Harbin Chimney Reinforcement Suihua Heihe Hoop Construction Company Qiqihar Mudanjiang< br/>Chimney repair Daxinganling lightning rod company, Jiamusi
Daqing chimney installation lightning rod construction company, Yichun Jixi chimney installation lightning protection and lightning protection system engineering construction manufacturer, Hegang Shuangyashan
Chimney ladder platform maintenance anti-corrosion welding construction manufacturer , Qitaihe
Songhua River Chimney Vertical Ladder Installation Cage and Net Construction Unit.
Construction unit: Anhui Hefei Thermal Power Co., Ltd.
Construction unit: Jiangsu Jinfeng High-altitude Construction Anti-corrosion Engineering Co., Ltd.
Website:
Project name: m reinforced concrete chimney Installation of lightning protection system ladder platform reinforcement, welding and anti-corrosion project
Construction location: In the courtyard of Anhui Hefei Thermal Power Co., Ltd.
Project manager: Liu Jiexin
Technical consultation:
E-mail:
@
Scope of project: m reinforced concrete chimney installation lightning protection system ladder platform reinforcement, welding and anti-corrosion project, the specific project quantities are as follows (can be determined based on the completed drawings, the calculation error will not be adjusted within the % range ).
One meter reinforced concrete chimney installation lightning protection system ladder platform reinforcement, welding and anti-corrosion project
Construction plan
Meter chimney installation lightning protection system ladder platform reinforcement, welding and anti-corrosion project construction basis
/> "Construction Organization Design" for this project
"Reinforced Concrete Chimney Design Drawings"
"Construction Quality Acceptance Specifications and Assessment Procedures for Electric Power Construction" (Civil Engineering Part/)
"Chimney Engineering Construction and Acceptance Specifications" (B)
"Construction Manual"
"Construction Engineering Project Management Specifications" (B/
"Building Construction Safety Inspection Standards" (
"Temporary Electricity Use at Construction Sites" Safety Technical Regulations" (
"Safety Regulations for the Use of Construction Machinery" (
"Safety Technical Regulations for Fastener Steel Pipe Scaffolding in Construction" (
"Construction Quality Acceptance Regulations for Building Foundation Foundation Projects" (B
Our company's documents related to quality, technology, safety and civilized construction
Other relevant standard specification documents, etc.
This project is a lightning rod installation and maintenance project for two brick chimneys of Xinhua Chemical Co., Ltd. The chimney of this project is high. It is a high-rise building. Due to long-term disrepair, smoke weathering, and corrosion from sulfur dioxide and other mixtures, the chimney lightning rods have corroded and rotted, and the down conductors have been severely corroded. The construction height of this project is high and difficult. Among them, the clay brick top of the chimney has been pressed. It is severely corroded and loose, and the lightning rod cannot be fixed. In addition, the temperature at the chimney outlet is nearly 100 degrees. It is necessary to add hoops to reinforce it. Two hoops are added to the top to fix the lightning rod. To ensure safe production and ensure the same safety of construction personnel, maintenance is carried out. Our company has a We have a professional chimney maintenance and construction team with rich theoretical and practical experience, strong skills, and hard-fighting skills. They are capable of meeting the needs of this project in terms of operation and management, as well as high-altitude construction technology.
Construction technical requirements
About the platform The installation and construction of the chimney lightning rod shall be strictly in accordance with the technical specifications for electric power construction and acceptance "Boiler Unit Electrical Chapter"/, and the ground connection rectification shall be in accordance with the "Construction and Acceptance Specifications for Grounding Devices in Electrical Installation Projects" B. When all old items on the chimney are removed, all use Demolition can only begin after the ropes are tied securely, and then transported vertically to the ground with ropes to prevent objects from falling from heights from injuring other people and equipment. All construction materials are not allowed to be reused, and must be confirmed and approved by Party A for special reasons, otherwise they will be treated as Rework for Party B. The lightning rod is made of stainless steel elements and materials, and all welding points must be fully welded. The hoop for fixing the lightning rod is made of stainless steel flat steel hoop. The bottom grounding lead is rectified and buried in the ground, and the part upwards is made of stainless steel material and ground. The down conductors are connected with stainless steel flat steel drilled gong bolts to facilitate inspection and maintenance. Installation and construction, civilized construction and environmental protection requirements. The characteristics of this project are short construction period, single profession, high quality and process requirements, high-altitude operation level is special, and construction style The inspection level is high, and for this reason, measures have been formulated.
Adhering to the principle of safety first and zero accidents, Party A's various safety regulations and measures should be strictly observed. Obey the safety supervision of safety management personnel, prevent violations and prevent accidents.
During the construction process, all construction workers must wear safety helmets, safety belts, and dust masks. All high-altitude workers must hold a high-altitude suspension operation certificate issued by the State Administration of Work Safety to work. It is strictly prohibited to work while sick, drunk, fatigued and mentally ill. The construction site must have security or protective nets in place, various on-site safety measures must be taken, and a dedicated person should be assigned to supervise the placement of on-site equipment and materials. All fire protection facilities must be in good condition, clearly marked, neat and orderly, and standards of civilized production at the construction site must be met. and requirements.
Jinfeng high-altitude engineering qualifications: Jinfeng official website:
Safety production license level 1
Professional contracting of high-altitude work projects
Professional contracting of high-altitude structure projects
Mechanical and electrical equipment installation Professional Contracting of Engineering
Professional Contracting of Anti-corrosion and Insulation Engineering
Professional Contracting of Building Waterproofing
Each construction employee has an electrician’s certificate for working at heights, an oxygen welder’s certificate, and an accidental injury insurance policy. The relevant certificate number is consistent with the ID number.
Jiangsu Jinfeng High-altitude Construction and Anti-corrosion Engineering Co., Ltd.
Address: Xindu Road, Yancheng City, Jiangsu Province
Postcode:
Telephone:
Fax:
Project Manager: Liu Jiexin
Mobile:
Website:
Email: @
Disclaimer
The information/pictures/parameters, etc. displayed on this webpage about【Heilongjiang Province cooling tower installation lightning rod manufacturer repairs lightning rod unit】are provided by member【Jiangsu Jinfeng Aerial Engineering Co
】,By Titker Trade Network members 【Jiangsu Jinfeng Aerial Engineering Co
】is solely responsible for the authenticity, accuracy and legality of the information/pictures/parameters, etc.,Titker Trade Network only provides display services. For your safety, please choose Titker Trade Network for online trading, otherwise Titker Trade Network will not bear any responsibility for this.
If your legitimate rights and interests have been infringed, please contact Titker Trade Network customer service as soon as possible. We will serve you wholeheartedly. Thank you for your attention and support to Titker Trade Network!