Hello and welcome toTitker Trade Network!
Concrete test instrument, cement test instrument, highway geotechn

free member

DT-W18 concrete vibration meter wholesale price

total supply
0
MOQ
0
brand
兴龙仪器
area
HebeiCangzhou City
Delivery period:
Shipped within 3 days from the date of payment by the buyer
Buyers are still looking
  • 1
  • 2
  • 3
Products Recommended

CCB-70B concrete car

Negotiable

SP-175 type mortar s

Negotiable

QZ-20 wall brick spe

Negotiable

HQM-I type concrete

Negotiable

JSS30A type digital

Negotiable

SM-500 type cement t

Negotiable

Shop information

area:Hebei Cangzhou City

Member level:corporate memberYear1

identity:  

Already paid:0.00 yuan deposit

my badge: [Integrity File]

online service:

Business card

Cangzhou Xinglong Engineering Instrument Co

Applets
【Kind tips】When you call, please mention that you saw us on Titker Trade Network, thank you.
Product Details

Concrete dynamometer Wholesale price of dynamometer
Overview of concrete dynamometer
Suitable for durability testing of concrete, acrylic mortar, etc., to measure the resonance rate of concrete or mortar specimens in a certain vibration mode , and then calculate the dynamic coefficient of concrete. It can be used with standard test pieces such as elastic modulus test molds, flexural test molds and freeze-thaw test chambers to determine the degree of damage to concrete during freeze-thaw cycles or chemical erosion. It is also suitable for concrete, carbon, stone slabs, bricks, and glass. As well as the dynamic elasticity and elastic modulus of non-metallic materials such as steel, copper, and aluminum are measured.
Features of the concrete dynamometer:
This dynamometer uses a single-chip microcomputer and integrated circuit to design and process data, realizing automation of the entire test and calculation process.
Technical parameters of concrete vibration meter:
, frequency measurement range:, measurement error: <﹪, frequency sensitivity:, output power:, output mode, digital tube display
, oscilloscope tube graphic display , printer printing, environmental conditions ℃ relative humidity <﹪, working time: continuous working hours, power supply %,, <
Operation method of concrete vibration meter
, Connect the input and output lines of the instrument, and connect the probe Installed on the bracket respectively, adjust the height and fix it reliably.
Align the test piece according to different requirements, turn on the power switch, and the instrument enters manual or automatic testing status.
. Automatic test status: digital display shows, waiting for key input instructions
() Single key (default): The conversion instruction for a single test is: when the single indicator light is on, it is a single test. At this time The result is output for each measurement. When the light is off, it is a double test. At this time, the result is output once for every two measurements, and the result is the average of the two times.
() Press the automatic manual key: convert the command to automatic test: when the automatic indicator light is on, it is automatic test. Manual test: When the manual indicator light is on, it is a manual test.
() Press the back key to enter the command, see the input status for details
() Press the test key: the automatic test command of the actuator: the digital display flashes continuously and enters the automatic scanning test state. At this time, you can hear the transmitting probe There is a sound with changing frequency, and the waveform of the oscilloscope also changes. The test is completed in about half a minute. If it is a double measurement state, it will display waiting to press the test button for the second test. If it is a single test state, the display will display the elastic modulus value. After a period of time, it will display the resonant frequency value. When displaying the elastic modulus value, if the printer is online, it will print out the test results. After printing, press the confirm key to print another copy of the test data. Press other keys to return to the display state and wait for the next input command.
() Press the upper limit key to display. At this time, you can press the numeric keys to enter the end value of the scanning frequency. After inputting, you can press the confirmation key to save the upper limit value, or press the back key to exit without saving the data.
() Press the limit key to display. At this time, you can press the numeric keys to enter the starting point value of the automatic scanning frequency. After completing the input, you can press the confirmation key to save the lower limit value, or press the return key to exit without saving the data.
() Press the time key to display. At this time, the instrument can be used as an electronic clock. Press any other key to display the status.
. Manual test status: The first five digits of the display display the frequency value, the last two digits display the amplitude value (relative value, used to determine the resonance point), and the oscilloscope displays the Lissajous figure. Tilting instrument
() Press the ^^ or key, the frequency will increase or decrease rapidly
() Press the ^^ or key, the frequency will increase or decrease rapidly
() Press the ^ or key, the frequency will increase or decrease slightly
() Press the ^ or key, the output power will increase or decrease accordingly
When pressing the above function keys to change the frequency or power, look at the amplitude value and Lissajous figure together. When the maximum amplitude point is found, That is the resonant frequency point.
Press the confirm key to directly output the result.
, Concrete Vibration Meter Input Status
Press the Back key for the first time to enter the width, then press Confirm to enter the length, and press Confirm again to enter the weight. When pressing back continuously, if the first time is the width, the second time is to enter the serial number, the third time is to enter the time, and the fourth time is to enter the date.
) Input width: Displayed on the monitor. At this time, you can enter the side length using numbers and decimal points. The unit is. Press the confirm key to receive the data and enter the length. Press the return key not to receive the data, but to enter the serial number.
b) Input length: The display shows that you can press the numeric and decimal point keys to enter the length of the specimen in units. Press the confirm key to receive the data and go to the input weight. Press the back key not to receive the data but go to Enter the side length.
) Input weight: When the display shows that you can press the numbers and decimal point keys to input the weight of the specimen, the unit is. Press the confirm key to receive the data and go to the automatic post-manual test state.
) Input serial number: The display shows that you can press the numeric keys to input the serial number, press the confirm key to receive the data, and then enter the side length. Press the back key not to receive the data, but to enter the time.
) Input time: The display shows it, and the two high digits are hours, the middle two digits are minutes, and the low two digits are seconds.
.When the upper two digits are flashing, you can enter the hour (hour). Press the confirmation key to confirm the data. At the same time, the middle two digits are flashing to enter minutes. Press the back key not to confirm the data, but to enter the date.
.When the middle two digits are flashing, you can enter minutes. Press the confirmation key to confirm the data. At the same time, the lower two digits are flashing and the input is entered. Press the back key without confirming the data. The upper two digits are flashing and the input is input. Hour.
.When the lower two digits are flashing, you can enter seconds. Press the confirmation key to confirm the data and enter the serial number. Press the back key without confirming the data. The middle two digits are flashing and move to minutes.
Input date: the display shows, and the high digit flashes. The high digit is the year, the middle digit is the month, and the low digit is the day.
.When the upper two digits are flashing, you can enter the year. Press the confirmation key to confirm the data. At the same time, the middle two digits are flashing. Enter the day. Press the confirmation key to confirm the data, but it will switch to the automatic or manual test state.
.When the middle two digits are flashing, you can enter the day. Press the confirmation key to confirm the data. The lower two digits are flashing. At the same time, you can enter the day. Press the confirmation key to confirm the data. Then you can enter the year. At this time, the upper two digits are flashing. move.
.When the lower two digits are flashing, you can enter the day. Press the confirmation key to confirm the data and enter the time. Press the back key without confirming the data. When the middle two digits are flashing, you can enter the month.
Must-read for experimental operation of concrete dynamometer
During the experiment, the instrument and test block should be placed on a solid platform, and it is best to place a rubber pad under the test block.
Place the transmitting probe at the middle position on the side of the test block, and place the receiving probe at the same end of the transmitting probe from the edge. At the same time, the probe should reach the middle of the height of the test block.
After placing the probe, first press the transmitting probe firmly, then adjust the instrument to the manual state, and then adjust the resonant frequency on the display appropriately to make it the same or similar to the frequency of the test block, and then adjust the receiving probe appropriately. The distance relationship with the test block. At this time, the graphics on the oscilloscope will change, and the last two digits on the display will also change. At this time, place the receiving probe at the position where the graphics is the largest or the amplitude value is the largest, then the probe is in good contact.
Do not change the parameters in the instrument at will (except weight, time, date), otherwise it will affect the experimental results.
The environment where the instrument is located must be dry to prevent electronic components from getting damp and affecting their lifespan.
Packing list of dynamometer, concrete dynamometer, digital dynamometer
Serial number name quantity unit remarks
Vibration instrument stand
Power cord
Probes
Instruction Manual
Certificate of Conformity
"DT-W18 concrete vibration meter wholesale price"Related Products
Related categories
室内环保检测仪器 Meteorological instruments gas analyzer Chromatograph Rubber and plastic special instruments Test chamber and climate environment equipment Thermometers Pressure instrument biological instrument flow meter Mechanical measuring instruments Experimental equipment Measuring standard instruments valve sensor Measuring tools measuring instrument Weighing instrument Level instrument Display instrument Transmitter Environmental testing instruments Logger counter Industrial timer Control (regulating) instruments Actuator base instrument Testing Machine Analytical Instruments Optical Instruments Electrical instrumentation car instrument Non-destructive testing instruments Electronic measuring instruments Special instrumentation Instruments and accessories Pneumatic unit combination instrument Electric unit instrument cluster Instrument power supply Automated complete control system Centralized control device Inventory instrumentation Packaging testing equipment Second hand instruments Other uncategorized Disinfection machine VOC detection equipment Ray detection equipment Formaldehyde detection equipment Benzene detection equipment Ammonia gas detector Other indoor environmental testing instruments
Related Information
Plastic tube rotor flowmeter manufacture Zezhou micromotor detector standard type Zezhou micromotor detector high current Zezhou flat motor special type (mobile p Inugami third generation underground met Solid phase extraction instrument-12 wel Circular solid phase extraction instrume Photochemical reaction instrument, multi Small spray dryer, small spray drying eq No need to process ordinary playing card Large-sized high-strength bolt detector Genuine Beigang Institute bar tensile sp Standard impact specimen impact test blo Jinan Nake specializes in the production Factory direct supply of authentic Beiga
Disclaimer

The information/pictures/parameters, etc. displayed on this webpage about【DT-W18 concrete vibration meter wholesale price】are provided by member【Cangzhou Xinglong Engineering Instrument Co 】,By Titker Trade Network members 【Cangzhou Xinglong Engineering Instrument Co 】is solely responsible for the authenticity, accuracy and legality of the information/pictures/parameters, etc.,Titker Trade Network only provides display services. For your safety, please choose Titker Trade Network for online trading, otherwise Titker Trade Network will not bear any responsibility for this.

If your legitimate rights and interests have been infringed, please contact Titker Trade Network customer service as soon as possible. We will serve you wholeheartedly. Thank you for your attention and support to Titker Trade Network!

Titker Trade Network