- 温度范围:
- 10℃~50℃
- 温度均匀度:
- ±2℃
- 温度波动度:
- ±0.5℃
● Working chamber size** Preface
With the rapid development of modern industrial technology, the application fields of rubber and plastic products are becoming increasingly broad, and the environmental conditions they are subjected to are becoming more and more complex and diverse. Only by reasonably specifying the environmental conditions of the product and correctly selecting the environmental protection measures for the product can the product be protected from damage during storage and transportation and be safe and reliable during use. Therefore, artificial simulated environmental testing of rubber and plastic products is an indispensable and important link to ensure their high quality. The artificial simulated environment test is a scientific summary of the actual environmental impact, and has the characteristics of being typical, standardized, easy to use and easy to compare. The diversification of environmental conditions and the importance of environmental testing also put forward more stringent requirements for environmental testing equipment.
The damage to materials caused by temperature and moisture has attracted people's attention. Today, our industrial technology is becoming more and more developed, and it is also causing more and more serious damage to the natural environment. Various corrosive gases caused by various manufacturing industries are mixed in the air, such as ozone. Its destructiveness is very serious for materials or products. test.
This ozone aging test equipment can be used to deform rubber products such as vulcanized rubber, thermoplastic rubber cable insulation sheaths and other products under static stretching or continuous dynamic stretching deformation, or under alternating intermittent dynamic stretching and static stretching. The sample is exposed to a closed, non-illuminated air containing constant ozone concentration and a constant temperature test chamber for a predetermined time to detect cracks or other changes in properties on the surface of the sample to evaluate the ozone aging resistance of the rubber.
Reference standards
● / Dynamic tensile test method for ozone aging resistance test of vulcanized rubber
● / Static tensile test method for ozone cracking resistance of vulcanized rubber or thermoplastic rubber
● / Cable insulation and General test methods for sheath materials
● Test methods stipulated in other relevant standards
Product use restrictions
This test equipment is prohibited from testing media with the following conditions
● Flammable, explosive and volatile Testing and storage of corrosive substance samples
● Testing and storage of corrosive substance samples
● Testing and storage of biological samples
● Testing and storage of strong electromagnetic emission source samples
br/> Equipment performance parameters
● Temperature range~ ● Temperature uniformity● Temperature fluctuation● Temperature deviation
● Humidity range
● Humidity uniformity~ ● Temperature rise and fall rate
● Time setting range ~ hours
● Ozone concentration
● Ozone concentration deviation ● Sample rack rotation speed/
● Clamp elongation rate ~
● Total power
● Power supply voltage
Mechanical sheet metal structure
● The outer wall is processed by CNC machine tools to form a beautiful and elegant steel plate with electrostatic spraying
● The inner wall is processed by CNC machine tools to form stainless steel plates
● The door is reasonably positioned A transparent window is used to observe the changes in the indoor sample. The observation window is made of multi-layer insulating tempered glass, which has the advantages of transparent heat insulation and explosion-proof.
● The use of low-noise multi-wing centrifugal fans for air circulation avoids any dead corners and can make the test area Temperature, humidity and ozone are evenly distributed. The air outlet and return air circulation design of the air path meets the test standards, and the wind pressure and speed meet the test standards and can quickly stabilize the temperature and humidity when opening the door
● The test door and the machine body adopt double-layer ozone-resistant high-tensile silicone sealing strips to ensure Sealing of the test area
● The refrigeration system of the equipment is installed below the working room and the compressor adopts imported Taikang brand
● High-quality fixed movable wheels are installed at the bottom of the instrument to easily move the instrument to the designated position. Fix the instrument
● The control part of the equipment is designed on the right side of the equipment, with temperature controller control switches, etc., which are convenient to operate, simple and easy to maintain
● The test space is equipped with dynamic and static pulleys that can only be used for dumbbell-shaped tests. Extension fixed fixture
Tensile test
The standard stipulates that the two ends of the test specimen are clamped on special fixtures. Select an elongation rate for stretching. Generally, the fixture is installed on a rotating sample rack. The rotation speed of the sample rack is between / The test is carried out at a specified stretching rate of the clamp at a temperature of a specified ozone concentration or by cyclic stretching and reset and rotating with the sample holder. After the specified time, check the cracks of the sample. Generally, the ozone concentration selection can also adjust the ozone concentration according to the pre-agreed concentration.
Heating system
● Heating uses far-infrared nickel-chromium alloy high-speed heating electric heating wire
● The heater control method is non-contact periodic pulse width modulation
● The output power is calculated by a microcomputer To achieve high efficiency in electricity use
Humidification and dehumidification system
● Adopt parallel micro-movement humidification system
● Comes with double overheating overflow guarantee device
● Water level control adopts mechanical float The ball water raft eliminates electronic malfunction
● The control output power is calculated by a microcomputer to achieve high precision and high efficiency in electricity use
● Uses evaporator coil dehumidification method
Refrigeration system< br/> ● The refrigeration machine adopts a fully enclosed French Taikang high-efficiency and energy-saving air-cooled mechanical compressor
● Refrigeration method single-machine refrigeration method
● Fin-type evaporator
● Internal spiral type Refrigerant copper pipe● All system pipelines are tested for ventilation and pressure leakage● Compressor return air cooling circuit
● Energy adjustment circuit● Refrigerant● The main components are all made of international high-quality brand products Imported drying filter High reliability refrigeration electromagnetic Valve
Electrical control system
● The temperature, humidity and ozone concentration control instrument is a touch screen digital display controller imported from Canada
● The temperature, humidity and ozone concentration are directly displayed
● Display accuracy
● Temperature sensor platinum resistance tester
● Control method Thermal balance temperature adjustment method
● Temperature and humidity control adopts system co-channel coordinated control ● The main electrical components are made of French Schneider, Japanese Fuji and other brands
Schneider AC contact Thermal overload protector Schneider relay
Ozone generator
● The ozone generator is German technology and adopts silent
Air-cooled electrode cooling method, the electrode is not hot. The generator has unique technology. Generate nitrogen oxygen
The compound ozone is mixed into the water without bromate ozone generator
Generation
● Ozone production amount ~/ ● Electrode cooling method air cooling
● Ozone generation air supply source Air
Protection system
● Over-temperature protection
● Compressor over-pressure protection
● Compressor overload protection
● Compressor over-current protection
● Missing Water protection
● Power supply phase loss/reverse phase protection
● Automatically shut down if there is a fault and display the fault content in Chinese
Environmental usage conditions
● The ground should be flat and well ventilated, and it should not be flammable or explosive. Corrosive gases and dust
● There are no strong electromagnetic radiation sources nearby
● There is a drainage floor drain near the equipment
● The load-bearing capacity of the site ground is not less than
● There is appropriate maintenance around the equipment Space
● Temperature
● Relative humidity
● Air pressure
● ● Allowable fluctuation range of voltage ● Allowable fluctuation range of frequency
● The grounding resistance of the protective ground wire is less than the mode power supply or mode Power supply
● The user is required to configure a power switch of corresponding capacity for the equipment at the installation site and this switch must be independent and dedicated for the use of this equipment
● The ambient temperature should be maintained within ~ when the equipment is not working. When the ambient temperature is low The water remaining in the equipment should be drained cleanly
Random information
● Operating instructions circuit diagram
● Certificate and warranty card
● Precautions for shipment and maintenance of basic accessories
/>Delivery Instructions
● The supplier is responsible for door-to-door delivery and delivery within one working day after the prepayment is received
● After the contract is signed, the demand side pays the total amount in advance within one day and pays it once after the goods arrive and are accepted. Clear
● The supplier is responsible for the installation, debugging and operation introduction until the purchaser’s employees operate independently
● The one-year warranty period starts from the date of installation acceptance. The supplier promises to provide lifetime spare parts after-sales service. If the supplier must go to the site to solve the problem, it will arrive at the user's site within hours.