- 抗压强度(mpa):
- 68.5
- 抗弯强度(mpa):
- 51.1
- 钢-钢拉伸剪切强度标准值(MPa):
- 15.7
Epoxy
Saturated
Reinforcement adhesive
- Reinforcement adhesive is a solvent-based chemical cohesion reaction type modified epoxy resin adhesive. Component A: Component B
- Rebar planting glue is suitable for rooting and anchoring projects.
★
Specific application scope:
, column steel bar implantation: column extension, structural column extension, shear wall concealed column, column increase cross-sectional area reinforcement.
. Filling and reinforcement of openings: floor connections or openings, wall connections or openings, construction openings, equipment or pipe openings, and stair openings.
New wall reinforcements: shear wall reinforcements, infill wall tie bars, underground diaphragm wall connections, retaining wall connections, and pool walls.
Newly added inclined plate steel bars: step stair slabs, spiral stair slabs, underground car ramp slabs, and bucket slabs.
, Cantilevered structural steel bars: cantilevered beams, cantilevered panels, balconies, stairways and walkway platforms.
. Reinforcement connections for new structures: structural beams, structural slabs, and structural foundations.
, Tunnel engineering structural connections: underground continuous walls, culverts, tunnels.
, Bridge and road reinforcement and reconstruction: railway bridges, highway bridges, highways, and runway coverage and reinforcement.
★
Technical indicators: Comply with - standard technical indicator requirements.
Performance items
Inspection results
Performance requirements (level)
Glue
Body
Performance
Energy
Compressive strength
/>
Flexural strength
And must not show brittle (fragmentation) failure
Adhesion
Bonding
Energy
Force
Standard value of steel-steel tensile shear strength
Normal tensile bond strength to concrete
., and cohesive failure of concrete
.And it is cohesive failure of concrete
Bonding strength of ribbed steel bars and concrete under constrained pull-out conditions
★
Instructions for use
Mix the components A and B of the reinforcement glue with an electric drill respectively to avoid mixing ratio errors and affecting the curing time due to precipitation during storage. .
. Mix the reinforcement glue according to the ratio of component A: component B and stir evenly before use.
★
Notes
When the temperature is low, component A and component B can be warmed in a warm water pot (barrel) at ~℃ to reduce the viscosity.
The construction environment temperature should be below ℃. The initial setting time is 1 hour at normal temperature. It will be completely cured in one day at normal temperature. The curing time will be slightly longer in negative temperature or humid environments.
★
Storage and Transportation
This product can be stored at an ambient temperature below ℃ and has a shelf life of three months.
This product is a solvent, so it should be stored away from open flames, heating devices, etc.
Yuan
(+)/Group
Yuan/Group.